Article: Standardization of the ultrasound examination of the masseter muscle with size-independent calculation of records.
Advances in clinical and experimental medicine : official organ Wroclaw Medical University
2021 Volume 30, Issue 4, Page(s) 441–447
Abstract: ... Material and methods: An ultrasound examination of 124 masseter muscles was performed. Axial examination ... Conclusions: The ultrasound study showed that masseter muscle thickness significantly differs depending ... for clinical purposes by devising the size-independent parameter. The size-independent parameter ...
Abstract | Background: As ultrasonography provides objective parameters and values, it is a reliable method of examining the structure and dimensions of the masseter muscle. Although the method is well known, there is no standardization in clinical examination and data analysis yet. Objectives: The study aimed to measure masseter muscle thickness in designated areas to establish the most repeatable and clinically applicable method of ultrasound examination, and to assess differences in measurements in designated areas for clinical purposes by devising the size-independent parameter. The size-independent parameter may potentially be more clinically applicable than distance records, which are affected by the size of the subject. Material and methods: An ultrasound examination of 124 masseter muscles was performed. Axial examination in 3 horizontal regions (lower, middle and upper) and coronal examination in 2 vertical regions (proximal and distal) was carried out. Masseter muscle thickness was measured in every designated area when relaxed (muscle at rest (RMT)) and with clenched teeth (contracted muscle (CMT)). A morphological independent functional index of thickness difference (FITD) was calculated. Results: The study revealed very high statistical differences between RMT and CMT (p < 0.0001) in all designated areas but with location variations. Masseter muscle thickness significantly differed depending on the examined area and transducer projection. Conclusions: The ultrasound study showed that masseter muscle thickness significantly differs depending on the examined area. The authors emphasize the necessity to examine the masseter muscle in specified areas with both coronal and axial projections to achieve objective and repeatable examination. Notable clinical value is assigned to FITD, which is independent from the morphological dimensions of the muscle. |
|||||
---|---|---|---|---|---|---|
MeSH term(s) | Masseter Muscle/diagnostic imaging ; Reference Standards ; Ultrasonography | |||||
Language | English | |||||
Publishing date | 2021-04-22 | |||||
Publishing country | Poland | |||||
Document type | Journal Article | |||||
ZDB-ID | 2270257-X | |||||
ISSN | 1899-5276 ; 1230-025X | |||||
ISSN | 1899-5276 ; 1230-025X | |||||
DOI | 10.17219/acem/130358 | |||||
Shelf mark |
|
|||||
Database | MEDical Literature Analysis and Retrieval System OnLINE |
More links
Kategorien
In stock of ZB MED Cologne/Königswinter
Zs.A 6489: Show issues | Location: Je nach Verfügbarkeit (siehe Angabe bei Bestand) bis Jg. 2021: Bestellungen von Artikeln über das Online-Bestellformular ab Jg. 2022: Lesesaal (EG) |
Order via subito
This service is chargeable due to the Delivery terms set by subito. Orders including an article and supplementary material will be classified as separate orders. In these cases, fees will be demanded for each order.