Article ; Online: Effects of electroacupuncture at BL33 on detrusor smooth muscle activity in a rat model of urinary retention.
Acupuncture in medicine : journal of the British Medical Acupuncture Society
2017
Abstract: Background: Detrusor smooth muscle (DSM) underactivity may lead to urinary retention (UR ... Electroacupuncture (EA) at BL33 may be effective in improving DSM contractions.: Objectives: This study aimed ... with urethane and modelled by urethral outlet obstruction. First, 2 Hz EA at BL33, SP6 and LI4 wasrandomly ...
Abstract | Background: Detrusor smooth muscle (DSM) underactivity may lead to urinary retention (UR). Electroacupuncture (EA) at BL33 may be effective in improving DSM contractions. Objectives: This study aimed to investigate: (1) the effect of EA at BL33; and (2) the effect of different manipulation methods at BL33 on the modulation of DSM contractions in UR rats. Methods: 30 male Sprague-Dawley rats were anaesthetised with urethane and modelled by urethral outlet obstruction. First, 2 Hz EA at BL33, SP6 and LI4 wasrandomly applied to the UR rats for 5 min to observe the immediate effects (n=10); second, manual acupuncture (MA) (n=10) and 100 Hz EA (n=10) were applied with the same programme. DSM electromyography (EMG) and cystometrogram data were evaluated. Results: (1) 2 Hz EA at BL33 and SP6 significantly increased DSM discharging frequency (0.80±0.10 Hz, P<0.001, and 0.22±0.14 Hz, P=0.038), shortened micturation intervals (65.67±20.65 s, P=0.008, and 35.62±15.84 s, P=0.042), prolonged the duration of voiding (2.13±0.61 s, P=0.005, and 0.47±0.16 s, P=0.015), and reduced residual pressure (-0.91±0.31 mmHg, P=0.019, and -0.66±0.27 mmHg, P=0.046). EA at LI4 was not associated with any functional effects (P>0.05). Compared with SP6, EA at BL33 had greater positive effects on DSM discharging frequency, duration of discharging, and duration of voiding (all P<0.05). (2) No statistically significant differences were shown betweenMA, 2 Hz EA and 100 Hz EA interventions when stimulating at BL33, SP6 or LI4. Conclusions: EA at BL33 improved DSM contractions to a greater degree than EA at SP6 or LI4. There were no differences in effect when stimulating using 2 Hz EA, 100 Hz EA and MA. |
|||||
---|---|---|---|---|---|---|
Language | English | |||||
Publishing date | 2017-11-06 | |||||
Publishing country | England | |||||
Document type | Journal Article | |||||
ZDB-ID | 1360533-1 | |||||
ISSN | 1759-9873 ; 0964-5284 | |||||
ISSN (online) | 1759-9873 | |||||
ISSN | 0964-5284 | |||||
DOI | 10.1136/acupmed-2016-011355 | |||||
Shelf mark |
|
|||||
Database | MEDical Literature Analysis and Retrieval System OnLINE |
More links
Kategorien
In stock of ZB MED Cologne/Königswinter
Zs.A 4628: Show issues | Location: Je nach Verfügbarkeit (siehe Angabe bei Bestand) bis Jg. 1994: Bestellungen von Artikeln über das Online-Bestellformular Jg. 1995 - 2021: Lesesall (2.OG) ab Jg. 2022: Lesesaal (EG) |
Order via subito
This service is chargeable due to the Delivery terms set by subito. Orders including an article and supplementary material will be classified as separate orders. In these cases, fees will be demanded for each order.