LIVIVO - The Search Portal for Life Sciences

zur deutschen Oberfläche wechseln
Advanced search

Search results

Result 1 - 1 of total 1

Search options

Article ; Online: Effects of electroacupuncture at BL33 on detrusor smooth muscle activity in a rat model of urinary retention.

Liu, Xiaoxu / Liu, Kun / Zhi, Mujun / Mo, Qian / Gao, Xinyan / Liu, Zhishun

Acupuncture in medicine : journal of the British Medical Acupuncture Society

2017  

Abstract: Background: Detrusor smooth muscle (DSM) underactivity may lead to urinary retention (UR ... Electroacupuncture (EA) at BL33 may be effective in improving DSM contractions.: Objectives: This study aimed ... with urethane and modelled by urethral outlet obstruction. First, 2 Hz EA at BL33, SP6 and LI4 wasrandomly ...

Abstract Background: Detrusor smooth muscle (DSM) underactivity may lead to urinary retention (UR). Electroacupuncture (EA) at BL33 may be effective in improving DSM contractions.
Objectives: This study aimed to investigate: (1) the effect of EA at BL33; and (2) the effect of different manipulation methods at BL33 on the modulation of DSM contractions in UR rats.
Methods: 30 male Sprague-Dawley rats were anaesthetised with urethane and modelled by urethral outlet obstruction. First, 2 Hz EA at BL33, SP6 and LI4 wasrandomly applied to the UR rats for 5 min to observe the immediate effects (n=10); second, manual acupuncture (MA) (n=10) and 100 Hz EA (n=10) were applied with the same programme. DSM electromyography (EMG) and cystometrogram data were evaluated.
Results: (1) 2 Hz EA at BL33 and SP6 significantly increased DSM discharging frequency (0.80±0.10 Hz, P<0.001, and 0.22±0.14 Hz, P=0.038), shortened micturation intervals (65.67±20.65 s, P=0.008, and 35.62±15.84 s, P=0.042), prolonged the duration of voiding (2.13±0.61 s, P=0.005, and 0.47±0.16 s, P=0.015), and reduced residual pressure (-0.91±0.31 mmHg, P=0.019, and -0.66±0.27 mmHg, P=0.046). EA at LI4 was not associated with any functional effects (P>0.05). Compared with SP6, EA at BL33 had greater positive effects on DSM discharging frequency, duration of discharging, and duration of voiding (all P<0.05). (2) No statistically significant differences were shown betweenMA, 2 Hz EA and 100 Hz EA interventions when stimulating at BL33, SP6 or LI4.
Conclusions: EA at BL33 improved DSM contractions to a greater degree than EA at SP6 or LI4. There were no differences in effect when stimulating using 2 Hz EA, 100 Hz EA and MA.
Language English
Publishing date 2017-11-06
Publishing country England
Document type Journal Article
ZDB-ID 1360533-1
ISSN 1759-9873 ; 0964-5284
ISSN (online) 1759-9873
ISSN 0964-5284
DOI 10.1136/acupmed-2016-011355
Shelf mark
Zs.A 4628: Show issues Location:
Je nach Verfügbarkeit (siehe Angabe bei Bestand)
bis Jg. 1994: Bestellungen von Artikeln über das Online-Bestellformular
Jg. 1995 - 2021: Lesesall (2.OG)
ab Jg. 2022: Lesesaal (EG)
Database MEDical Literature Analysis and Retrieval System OnLINE

More links

Kategorien

To top