LIVIVO - The Search Portal for Life Sciences

zur deutschen Oberfläche wechseln
Advanced search

Your last searches

  1. TI=Viscoelastic Coagulation Monitor as a Novel Device to Assess Coagulation at the Bedside A Single Center Experience During the COVID 19 Pandemic
  2. TI=Emerging mental health challenges strategies and opportunities in the context of the COVID 19 pandemic: Perspectives from South American decision makers

Search results

Result 1 - 1 of total 1

Search options

Article ; Online: Viscoelastic Coagulation Monitor as a Novel Device to Assess Coagulation at the Bedside. A Single-Center Experience During the COVID-19 Pandemic.

Panigada, Mauro / Meli, Andrea / Scotti, Eleonora / Properzi, Paolo / Brioni, Matteo / Kamel, Shady / Ghirardello, Stefano / Scudeller, Luigia / Dalton, Heidi J / Grasselli, Giacomo

ASAIO journal (American Society for Artificial Internal Organs : 1992)

2021  Volume 67, Issue 3, Page(s) 254–262

Abstract: Viscoelastic coagulation monitor (VCM) is a portable device developed to evaluate the viscoelastic ... the viscoelastic profiles of 36 COVID-19 intensive care patients. Full anticoagulant dose heparin (unfractionated ... patients and was easy to perform with minimal training at the bedside. ...

Abstract Viscoelastic coagulation monitor (VCM) is a portable device developed to evaluate the viscoelastic properties of whole blood activated by contact with glass. In this study, VCM was employed to analyze the viscoelastic profiles of 36 COVID-19 intensive care patients. Full anticoagulant dose heparin (unfractionated [UFH]; low molecular weight [LMWH]) was administrated to all patients. The association between VCM and laboratory parameters was retrospectively analyzed. The administration of UFH-influenced VCM parameters prolonging clotting time (CT) and clot formation time (CFT) and reducing angle (alpha) and amplitudes of the VCM tracings (A10, A20, and maximum clot firmness [MCF]) compared with LMWH therapy. A tendency toward hypercoagulation was observed by short CT and CFT in patients receiving LMWH. Clotting time was correlated with UFH dose (Spearman's rho = 0.48, p ≤ 0.001), and no correlation was found between CT and LMWH. All VCM tracings failed to show lysis at 30 and 45 minutes, indicating the absence of fibrinolysis. A10, A20, and MCF exhibited very-good to good diagnostic accuracy for detecting platelet count and fibrinogen above the upper reference limit of the laboratory. In conclusion, VCM provided reliable results in COVID-19 patients and was easy to perform with minimal training at the bedside.
MeSH term(s) Adult ; Blood Coagulation ; COVID-19/blood ; COVID-19/complications ; Female ; Humans ; Male ; Middle Aged ; Monitoring, Physiologic/instrumentation ; Monitoring, Physiologic/methods ; Point-of-Care Systems ; Retrospective Studies ; SARS-CoV-2 ; Thrombelastography/instrumentation ; Thrombelastography/methods ; Thrombosis/diagnosis ; Thrombosis/virology
Language English
Publishing date 2021-02-24
Publishing country United States
Document type Journal Article ; Observational Study
ZDB-ID 759982-1
ISSN 1538-943X ; 0162-1432 ; 1058-2916
ISSN (online) 1538-943X
ISSN 0162-1432 ; 1058-2916
DOI 10.1097/MAT.0000000000001380
Shelf mark
Uk I Zs.199: Show issues Location:
Je nach Verfügbarkeit (siehe Angabe bei Bestand)
bis Jg. 2021: Bestellungen von Artikeln über das Online-Bestellformular
ab Jg. 2022: Lesesaal (EG)
Zs.B 2435: Show issues Location:
Je nach Verfügbarkeit (siehe Angabe bei Bestand)
bis Jg. 2021: Bestellungen von Artikeln über das Online-Bestellformular
ab Jg. 2022: Lesesaal (EG)
Database MEDical Literature Analysis and Retrieval System OnLINE

More links

Kategorien

To top