Artikel: Investigation of potential aerosol transmission and infectivity of SARS-CoV-2 through central ventilation systems.

Pease, Leonard F / Wang, Na / Salsbury, Timothy I / Underhill, Ronald M / Flaherty, Julia E / Vlachokostas, Alex / Kulkarni, Gourihar / James, Daniel P

Building and environment

2021  Band 197, Seite(n) 107633

Abstract: ... of SARS-CoV-2 via air handling systems within multiroom buildings remains unexplored. This study evaluates ... transmission and infectious spread within individual rooms are well studied, the impact of aerosolized spread ... a well-mixed model in a multiroom building served by a central air handling system (without packaged ...

Abstract The COVID-19 pandemic has raised concern of viral spread within buildings. Although near-field transmission and infectious spread within individual rooms are well studied, the impact of aerosolized spread of SARS-CoV-2 via air handling systems within multiroom buildings remains unexplored. This study evaluates the concentrations and probabilities of infection for both building interior and exterior exposure sources using a well-mixed model in a multiroom building served by a central air handling system (without packaged terminal air conditioning). In particular, we compare the influence of filtration, air change rates, and the fraction of outdoor air. When the air supplied to the rooms comprises both outdoor air and recirculated air, we find filtration lowers the concentration and probability of infection the most in connected rooms. We find that increasing the air change rate removes virus from the source room faster but also increases the rate of exposure in connected rooms. Therefore, slower air change rates reduce infectivity in connected rooms at shorter durations. We further find that increasing the fraction of virus-free outdoor air is helpful, unless outdoor air is infective in which case pathogen exposure inside persists for hours after a short-term release. Increasing the outdoor air to 33% or the filter to MERV-13 decreases the infectivity in the connected rooms by 19% or 93% respectively, relative to a MERV-8 filter with 9% outdoor air based on 100 quanta/h of 5 μm droplets, a breathing rate of 0.48 m
Sprache Englisch
Erscheinungsdatum 2021-01-29
Erscheinungsland England
Dokumenttyp Journal Article
ISSN 0360-1323
ISSN 0360-1323
DOI 10.1016/j.buildenv.2021.107633
Datenquelle MEDical Literature Analysis and Retrieval System OnLINE