LIVIVO - The Search Portal for Life Sciences

zur deutschen Oberfläche wechseln
Advanced search

Search results

Result 1 - 10 of total 78

Search options

  1. Article ; Online: Postural change in intraocular pressure: a comparison of measurement with a Goldmann tonometer, Tonopen XL, pneumatonometer, and HA-2.

    Barkana, Yaniv

    Journal of glaucoma

    2014  Volume 23, Issue 1, Page(s) e23–8

    Abstract: Purpose: To compare directly the results of 4 tonometers in measuring postural change in the intraocular pressure (IOP) between sitting and lying body positions.: Methods: In 19 healthy subjects, the IOP was measured both eyes with a Goldmann ... ...

    Abstract Purpose: To compare directly the results of 4 tonometers in measuring postural change in the intraocular pressure (IOP) between sitting and lying body positions.
    Methods: In 19 healthy subjects, the IOP was measured both eyes with a Goldmann applanation tonometer (GAT) while sitting, then using the same GAT with the subject in the left lateral decubitus position after lying for 15 minutes, using a novel system comprising a motorized bed and a modified slit-lamp table. On the next day, the sitting IOP was measured in 1 eye using GAT, and additionally in random order Tonopen XL and pneumatonometer. Then subjects were asked to lie down, and the IOP was measured with these tonometers and also with a hand-held applanation tonometer (HA-2) after lying for 15 minutes and for 45 minutes; measurements were made with subjects in the supine position except with GAT.
    Results: There were 10 male and 9 female subjects, with a mean age of 33.0±12.4 years. On day 1, the sitting GAT IOP (mm Hg) was 13.7±3.0 right eye and 13.6±2.8 left eye (P=0.7) and the lying GAT IOP was 17.8±3.5 right eye and 18.1±3.2 left eye (P=0.3 for inter-eye postural IOP change). Postural change in the right and the left eyes was moderately correlated, with a coefficient of 0.453. On day 2, postural changes after lying for 15 minutes as measured with a GAT, a Tonopen, a pneumatonometer, and a HA-2 were 4.9±2.6, 1.6±1.8, 4.2±2.0, and 3.1±2.7, respectively. After lying for 45 minutes, it decreased to 3.3±2.1, 1.1±4.3, 3.1±2.5, and 2.6±3.3, respectively; this IOP decrease was statistically significant for the GAT and the pneumatonometer. The inter-subject variability was large, as in some subjects there was nearly no postural change in the IOP, whereas in some the IOP increased by 8 to 10 mm Hg. Ninety-five percent limits of agreement showed a poor agreement between GAT and the other 3 tonometers in the sitting and lying IOPs and postural IOP changes measured.
    Conclusions: The average postural IOP change was similar when measured with GAT and a pneumatonometer, smaller with a hand-held GAT, and much smaller with a Tonopen XL. This change decreased significantly when lying between the 15- and 45-minute time points. The inter-subject variability in postural IOP was remarkable, consistent with previous reports, suggesting the importance of this parameter in clinical glaucoma practice. Inter-device agreement was poor and similar to previous reports.
    MeSH term(s) Adult ; Female ; Healthy Volunteers ; Humans ; Intraocular Pressure/physiology ; Male ; Middle Aged ; Posture/physiology ; Tonometry, Ocular/instrumentation ; Young Adult
    Language English
    Publishing date 2014-01
    Publishing country United States
    Document type Comparative Study ; Journal Article ; Research Support, Non-U.S. Gov't
    ZDB-ID 913494-3
    ISSN 1536-481X ; 1057-0829
    ISSN (online) 1536-481X
    ISSN 1057-0829
    DOI 10.1097/IJG.0b013e3182a0762f
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  2. Article ; Online: Surgical outcomes of Ahmed glaucoma valve implantation with plate fixation using vicryl sutures or no plate fixation.

    Singer, Reut / Kapelushnik, Noa / Rotenstreich, Ygal / Leshno, Ari / Barkana, Yaniv / Skaat, Alon

    European journal of ophthalmology

    2021  , Page(s) 11206721211012869

    Abstract: Purpose: To summarize the surgical outcomes of Ahmed glaucoma valve (AGV) implantation with plate fixation with vicryl absorbable sutures or no plate suturing.: Methods: This study was a retrospective case series that included all glaucoma patients ... ...

    Abstract Purpose: To summarize the surgical outcomes of Ahmed glaucoma valve (AGV) implantation with plate fixation with vicryl absorbable sutures or no plate suturing.
    Methods: This study was a retrospective case series that included all glaucoma patients who underwent AGV implantation surgery with vicryl absorbable sutures for plate fixation or without plate fixation by a single surgeon between 2014 and 2019. We reviewed their medical records and retrieved clinical data on intra- and postoperative complications, best-corrected visual acuity, intraocular pressure (IOP), and number of IOP-lowering medications.
    Results: Twenty out of 29 eyes (29 patients, mean age 61.04 ± 27.1 years, 17 men) underwent AGV implantation without plate fixation and nine had AGV implantation with fixation with vicryl sutures. Complications were observed in 15 cases (51.7%). Nine of these were defined as failure due to the need for removal or repositioning of the AGV or for further surgery for uncontrolled IOP, of which five were no-fixation cases (5/20, 25%) and four were vicryl-fixation cases (4/9, 44.4%). Six of all surgical failures were related to AGV migration (6/9, 66.6%). There were three cases of extrusion and one case of plate migration in the no-fixation group, and two cases of plate migration and one case of extrusion in the vicryl-fixation group.
    Conclusion: AGV implantation without suture plate fixation or with vicryl suture fixation had a high complication and failure rate, often necessitating reoperation and AGV removal. The high rate of tube-related complications observed after both techniques does not favor either of them. The use of non-absorbable sutures for suturing of the AGV plate is recommended.
    Language English
    Publishing date 2021-04-28
    Publishing country United States
    Document type Journal Article
    ZDB-ID 1089461-5
    ISSN 1724-6016 ; 1120-6721
    ISSN (online) 1724-6016
    ISSN 1120-6721
    DOI 10.1177/11206721211012869
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  3. Article ; Online: Improved sensitivity of microperimetric outcomes for clinical studies in age-related macular degeneration.

    Barkana, Yaniv / Pondorfer, Susanne G / Schmitz-Valckenberg, Steffen / Russ, Hermann / Finger, Robert P

    Scientific reports

    2021  Volume 11, Issue 1, Page(s) 4764

    Abstract: To investigate sensitive outcome measures based exclusively on abnormal points in microperimetry testing of eyes with intermediate age-related macular degeneration (iAMD). 25 eyes of 25 subjects with iAMD had undergone 2 successive tests of mesopic ... ...

    Abstract To investigate sensitive outcome measures based exclusively on abnormal points in microperimetry testing of eyes with intermediate age-related macular degeneration (iAMD). 25 eyes of 25 subjects with iAMD had undergone 2 successive tests of mesopic microperimetry with the Macular Integrity Assessment Microperimeter (MAIA), using a custom grid of 33 points spanning the central 14 degrees of the macula. Each point was defined as abnormal if its threshold sensitivity was lower than 1.65 standard deviations (SD) (5%) or 2 SD (2.5%) than the expected threshold in healthy eyes according to the MAIA internal database. Among the 25 eyes there were 11.8 ± 9 and 8.4 ± 8.2 abnormal points at < 5% and < 2.5%, with mean deviation of thresholds from normal - 4.9 ± 1.2 dB and - 5.8 ± 1.5 dB, respectively. These deviations were greater, and their SD smaller, compared with the complete microperimetry grid, - 2.3 ± 2.0 dB. The 95% limits of agreement for average threshold between the 2 successive tests were smaller when only abnormal points were included. Analyzing only abnormal grid points yields an outcome parameter with a greater deviation from normal, a more homogenous dataset, and better test-retest variability, compared with analysis of all grid points. This parameter may thus be more sensitive to change, while moderately limiting the number of potential recruits. The proposed outcome measures should be further investigated as potential endpoints in clinical trials in iAMD.
    MeSH term(s) Aged ; Aged, 80 and over ; Clinical Trials as Topic ; Cross-Sectional Studies ; Diagnostic Techniques, Ophthalmological ; Female ; Humans ; Macula Lutea/pathology ; Macular Degeneration/diagnosis ; Male ; Middle Aged ; Retrospective Studies ; Visual Acuity
    Language English
    Publishing date 2021-02-26
    Publishing country England
    Document type Journal Article ; Research Support, Non-U.S. Gov't
    ZDB-ID 2615211-3
    ISSN 2045-2322 ; 2045-2322
    ISSN (online) 2045-2322
    ISSN 2045-2322
    DOI 10.1038/s41598-021-83716-w
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  4. Article ; Online: Er:YAG laser-assisted filtration surgery: initial results in rabbits.

    Kapelushnik, Noa / Leshno, Ari / Singer, Reut / Huna-Baron, Ruth / Barkana, Yaniv / Skaat, Alon

    BMC ophthalmology

    2021  Volume 21, Issue 1, Page(s) 226

    Abstract: Background: Glaucoma is a leading cause of global blindness, especially preventable blindness. The increased prevalence of glaucoma has led to a growing demand for newer, safer, more rapid, and simpler treatments for the reduction of intraocular ... ...

    Abstract Background: Glaucoma is a leading cause of global blindness, especially preventable blindness. The increased prevalence of glaucoma has led to a growing demand for newer, safer, more rapid, and simpler treatments for the reduction of intraocular pressure (IOP). In this study, we evaluated the safety and feasibility of performing filtration glaucoma surgery with an Ab-Interno Er:YAG laser in rabbits.
    Methods: Nine New Zealand White rabbits age 16 weeks were studied. After subconjunctival injection of mitomycin C (MMC), a novel Ab-Interno Er:YAG laser probe was inserted into the anterior chamber (AC) through a clear corneal 1 mm paracentesis and directed at the trabecular meshwork adjacent to the MMC injection area. A pulsed laser beam was applied to create a patent sclerostomy connecting the AC to the subconjuctival space, resulting in a filtering bleb. The laser system used was the Er:YAG laser system - LAS25-FCU, (Pantec Biosolutions AG, Liechtenstein). Parameters used: Wave lengh: 2940 nm, Pulse length: 100-400 μsec,frequency: 250 Hz. Average laser power in accordance to the fiber tip diameter: 0.85 W(range 0.8-0.92 W). Complete ocular exams, including IOP measurements, were performed on 1, 7, 14, and 23 days postoperatively. Three rabbits were sacrificed on days 1, 14, and 23, and histological examinations were performed on all nine eyes.
    Results: All procedures resulted in a functional medium-large superior bleb without significant complications. The bleb was sustained in all rabbits by day 14 and in one of the three rabbits that reached the last follow-up at 23 days. No cases of postoperative hypotony were observed. There was a transient significant reduction in mean IOP on postoperative days 5 and 7 (P = 0.028). Histopathological analysis revealed a patent full-thickness scleral tunnel with only a minor degree of surrounding coagulation necrosis.
    Conclusions: The Ab-Interno laser sclerostomy procedure is potentially safe and effective based on initial experience in an in-vivo rabbit animal model.
    MeSH term(s) Animals ; Humans ; Intraocular Pressure ; Laser Therapy ; Lasers, Solid-State/therapeutic use ; Rabbits ; Sclera ; Sclerostomy ; Trabecular Meshwork/surgery
    Language English
    Publishing date 2021-05-20
    Publishing country England
    Document type Journal Article
    ZDB-ID 2050436-6
    ISSN 1471-2415 ; 1471-2415
    ISSN (online) 1471-2415
    ISSN 1471-2415
    DOI 10.1186/s12886-021-01986-4
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  5. Article ; Online: Re: Tham et al.: Global prevalence of glaucoma and projections of glaucoma burden through 2040: a systematic review and meta-analysis (Ophthalmology 2014;121:2081-90).

    Barkana, Yaniv / Dorairaj, Syril

    Ophthalmology

    2015  Volume 122, Issue 7, Page(s) e40–1

    MeSH term(s) Female ; Glaucoma, Angle-Closure/epidemiology ; Glaucoma, Open-Angle/epidemiology ; Global Health/trends ; Humans ; Male
    Language English
    Publishing date 2015-07
    Publishing country United States
    Document type Comment ; Letter
    ZDB-ID 392083-5
    ISSN 1549-4713 ; 0161-6420
    ISSN (online) 1549-4713
    ISSN 0161-6420
    DOI 10.1016/j.ophtha.2014.11.030
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  6. Article ; Online: Histological and molecular characterization of glaucoma model induced by one or two injections of microbeads to the anterior chamber of mice.

    Zahavi, Alon / Friedman Gohas, Moran / Sternfeld, Amir / Daoud Zreiq, Nesrin / Muhsinoglu, Orkun / Ofri, Ron / BarKana, Yaniv / Goldenberg-Cohen, Nitza

    International ophthalmology

    2022  Volume 42, Issue 12, Page(s) 3763–3775

    Abstract: Purpose: To characterize glaucoma-induced damage following injections of plastic microbeads into the anterior chamber of mice.: Methods: Mice were divided into three groups: a single plastic microbeads injection (n = 21); two consecutive plastic ... ...

    Abstract Purpose: To characterize glaucoma-induced damage following injections of plastic microbeads into the anterior chamber of mice.
    Methods: Mice were divided into three groups: a single plastic microbeads injection (n = 21); two consecutive plastic microbead injections to the right eye at 1-week intervals, 4 of which with two consecutive saline injections in the left eye (n = 15); and an additional control group of two consecutive saline injections at 1-week intervals (n = 6). Intraocular pressure (IOP) was measured weekly. Retinal thickness, ganglion cells (RGCs) and axonal loss, inflammatory and gliosis reactions were measured at week four. Molecular analysis using qRT-PCR in the microbeads injection groups focused on expression levels of inflammation and glaucoma-related genes.
    Results: Mean IOP following single injection at 4 weeks was significantly elevated compared to baseline in injected eyes (14.5 ± 3.3 mmHg vs. 11.1 ± 2.5 mmHg, respectively, p = 0.003) and not in fellow eyes (13.2 ± 2.9 mmHg vs. 12.2 ± 2.9, respectively, NS). Six (35.3%) bead-injected eyes had IOP ≥ 17 mmHg compared with 2 (11.8%) saline-injected control eyes. Retinal thickness in injected and fellow eyes was 193.7 ± 15.5 µm and 223.9 ± 15.5 µm, respectively (p = 0.03). RGC loss in injected and fellow eyes was 16.0 ± 0.5 and 17.6 ± 0.7 cells per 200 µm, respectively (p = 0.005). Retinal gliosis, axonal loss and inflammatory cell infiltration to the bead-injected eyes were noted. Molecular analysis following double injection showed STAT3 expression decreased in the glaucoma-induced optic nerves (0.69 ± 0.3 vs. 1.16 ± 0.3, p = 0.04), but increased in the glaucoma-induced retinae (p = 0.05) versus saline; retinal IL-1β decreased significantly (0.04 ± 0.04 vs. 0.36 ± 0.2, p = 0.02). TNF-α, NFkB and SOD-1 expression did not change.
    Conclusion: One/two injections of microbeads elevated IOP, with measurable neuronal damage. An inflammatory response was detected in the injured retina and optic nerve. The therapeutic significance of these findings should be explored.
    MeSH term(s) Mice ; Animals ; Microspheres ; Retinal Ganglion Cells/pathology ; Gliosis/metabolism ; Gliosis/pathology ; Axons/metabolism ; Axons/pathology ; Disease Models, Animal ; Glaucoma/metabolism ; Intraocular Pressure ; Anterior Chamber/pathology ; Plastics/metabolism
    Chemical Substances Plastics
    Language English
    Publishing date 2022-06-22
    Publishing country Netherlands
    Document type Journal Article
    ZDB-ID 800087-6
    ISSN 1573-2630 ; 0165-5701
    ISSN (online) 1573-2630
    ISSN 0165-5701
    DOI 10.1007/s10792-022-02372-9
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  7. Article: Azithromycin and Sildenafil May Have Protective Effects on Retinal Ganglion Cells via Different Pathways: Study in a Rodent Microbead Model.

    Sela, Tal Corina / Zahavi, Alon / Friedman-Gohas, Moran / Weiss, Shirel / Sternfeld, Amir / Ilguisonis, Astrid / Badash, Danielle / Geffen, Noa / Ofri, Ron / BarKana, Yaniv / Goldenberg-Cohen, Nitza

    Pharmaceuticals (Basel, Switzerland)

    2023  Volume 16, Issue 4

    Abstract: Decreased blood flow to the optic nerve (ON) and neuroinflammation are suggested to play an important role in the pathophysiology of glaucoma. This study investigated the potential neuroprotective effect of azithromycin, an anti-inflammatory macrolide, ... ...

    Abstract Decreased blood flow to the optic nerve (ON) and neuroinflammation are suggested to play an important role in the pathophysiology of glaucoma. This study investigated the potential neuroprotective effect of azithromycin, an anti-inflammatory macrolide, and sildenafil, a selective phosphodiesterase-5 inhibitor, on retinal ganglion cell survival in a glaucoma model, which was induced by microbead injection into the right anterior chamber of 50 wild-type (WT) and 30 transgenic toll-like receptor 4 knockout (TLR4KO) mice. Treatment groups included intraperitoneal azithromycin 0.1 mL (1 mg/0.1 mL), intravitreal sildenafil 3 µL, or intraperitoneal sildenafil 0.1 mL (0.24 μg/3 µL). Left eyes served as controls. Microbead injection increased intraocular pressure (IOP), which peaked on day 7 in all groups and on day 14 in azithromycin-treated mice. Furthermore, the retinas and ON of microbead-injected eyes showed a trend of increased expression of inflammatory- and apoptosis-related genes, mainly in WT and to a lesser extent in TLR4KO mice. Azithromycin reduced the BAX/BCL2 ratio, TGFβ, and TNFα levels in the ON and CD45 expression in WT retina. Sildenafil activated TNFα-mediated pathways. Both azithromycin and sildenafil exerted a neuroprotective effect in WT and TLR4KO mice with microbead-induced glaucoma, albeit via different pathways, without affecting IOP. The relatively low apoptotic effect observed in microbead-injected TLR4KO mice suggests a role of inflammation in glaucomatous damage.
    Language English
    Publishing date 2023-03-24
    Publishing country Switzerland
    Document type Journal Article
    ZDB-ID 2193542-7
    ISSN 1424-8247
    ISSN 1424-8247
    DOI 10.3390/ph16040486
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  8. Article ; Online: Improved sensitivity of microperimetric outcomes for clinical studies in age-related macular degeneration

    Yaniv Barkana / Susanne G. Pondorfer / Steffen Schmitz-Valckenberg / Hermann Russ / Robert P. Finger

    Scientific Reports, Vol 11, Iss 1, Pp 1-

    2021  Volume 7

    Abstract: Abstract To investigate sensitive outcome measures based exclusively on abnormal points in microperimetry testing of eyes with intermediate age-related macular degeneration (iAMD). 25 eyes of 25 subjects with iAMD had undergone 2 successive tests of ... ...

    Abstract Abstract To investigate sensitive outcome measures based exclusively on abnormal points in microperimetry testing of eyes with intermediate age-related macular degeneration (iAMD). 25 eyes of 25 subjects with iAMD had undergone 2 successive tests of mesopic microperimetry with the Macular Integrity Assessment Microperimeter (MAIA), using a custom grid of 33 points spanning the central 14 degrees of the macula. Each point was defined as abnormal if its threshold sensitivity was lower than 1.65 standard deviations (SD) (5%) or 2 SD (2.5%) than the expected threshold in healthy eyes according to the MAIA internal database. Among the 25 eyes there were 11.8 ± 9 and 8.4 ± 8.2 abnormal points at < 5% and < 2.5%, with mean deviation of thresholds from normal − 4.9 ± 1.2 dB and − 5.8 ± 1.5 dB, respectively. These deviations were greater, and their SD smaller, compared with the complete microperimetry grid, − 2.3 ± 2.0 dB. The 95% limits of agreement for average threshold between the 2 successive tests were smaller when only abnormal points were included. Analyzing only abnormal grid points yields an outcome parameter with a greater deviation from normal, a more homogenous dataset, and better test–retest variability, compared with analysis of all grid points. This parameter may thus be more sensitive to change, while moderately limiting the number of potential recruits. The proposed outcome measures should be further investigated as potential endpoints in clinical trials in iAMD.
    Keywords Medicine ; R ; Science ; Q
    Subject code 310
    Language English
    Publishing date 2021-02-01T00:00:00Z
    Publisher Nature Portfolio
    Document type Article ; Online
    Database BASE - Bielefeld Academic Search Engine (life sciences selection)

    More links

    Kategorien

  9. Article ; Online: FOXC1 variant in a family with anterior segment dysgenesis and normal-tension glaucoma.

    Or, Lior / Barkana, Yaniv / Hecht, Idan / Weiner, Chen / Einan-Lifshitz, Adi / Pras, Eran

    Experimental eye research

    2020  Volume 200, Page(s) 108220

    Abstract: Our study describes the glaucoma phenotype in a family with Axenfeld-Rieger syndrome (ARS) and a FOXC1 variant. Included were 20 subjects from a large three generation family of Jewish Indian ancestry. Subjects underwent a comprehensive ophthalmic ... ...

    Abstract Our study describes the glaucoma phenotype in a family with Axenfeld-Rieger syndrome (ARS) and a FOXC1 variant. Included were 20 subjects from a large three generation family of Jewish Indian ancestry. Subjects underwent a comprehensive ophthalmic examination including automated perimetry and optical coherence tomography. Eight subjects were available for molecular analysis which included whole genome sequencing on selected patients and Sanger sequencing for variant screening. Eleven patients demonstrated a wide spectrum of Axenfeld-Rieger anomaly signs and symptoms. These ranged from subtle angle abnormalities to remarkable anterior segment abnormalities such as corectopia, iris adhesions and strands. Among them, six had glaucoma and two were glaucoma suspects. Of the six subjects with glaucoma three had high-tension glaucoma and two had normal-tension glaucoma. Molecular analysis revealed a previously described pathogenic variant in the FOXC1 gene (c.378C > G p.I126M; rs104893958), in six affected patients which was not identified in two healthy siblings. Molecular analysis also revealed a PITX2 missense variant (c.28T > A p.L10M; rs755864040) which did not segregate with clinical findings and was considered likely benign. In conclusion, patients with ARS due to FOXC1 variants may present with glaucomatous optic nerve damage without apparent elevation in IOP. Normal-tension glaucoma is less commonly reported in individuals with ARS and a comprehensive glaucoma assessment may be warranted in these individuals even with normal IOP. These findings raise the possibility that glaucomatous damage associated with FOXC1 is not only due to high IOP.
    MeSH term(s) Adolescent ; Adult ; DNA/genetics ; DNA Mutational Analysis ; Eye Abnormalities/genetics ; Eye Abnormalities/metabolism ; Female ; Forkhead Transcription Factors/genetics ; Forkhead Transcription Factors/metabolism ; Humans ; Low Tension Glaucoma/genetics ; Low Tension Glaucoma/metabolism ; Male ; Middle Aged ; Mutation ; Pedigree ; Phenotype ; Young Adult
    Chemical Substances FOXC1 protein, human ; Forkhead Transcription Factors ; DNA (9007-49-2)
    Language English
    Publishing date 2020-09-06
    Publishing country England
    Document type Journal Article ; Research Support, Non-U.S. Gov't
    ZDB-ID 80122-7
    ISSN 1096-0007 ; 0014-4835
    ISSN (online) 1096-0007
    ISSN 0014-4835
    DOI 10.1016/j.exer.2020.108220
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  10. Article ; Online: Surgical Outcomes of Ahmed Glaucoma Valve Implantation Without Plate Sutures: A 10-Year Retrospective Study.

    Kapelushnik, Noa / Singer, Reut / Barkana, Yaniv / Rosenfeld, Alik / Tucker, Yisrael / Jaber, Wasim / Gaton, Dan / Leshno, Ari / Skaat, Alon

    Journal of glaucoma

    2021  Volume 30, Issue 6, Page(s) 502–507

    Abstract: Prcis: Ahmed glaucoma valve (AGV) implantation without plate fixation resulted in high rates of complications related to plate or tube movement.: Purpose: Scleral suturing of the plate of AGV is associated with technical difficulty and potential ... ...

    Abstract Prcis: Ahmed glaucoma valve (AGV) implantation without plate fixation resulted in high rates of complications related to plate or tube movement.
    Purpose: Scleral suturing of the plate of AGV is associated with technical difficulty and potential complications. This study summarizes the surgical outcomes of 10 years of experience with AGV implantation without suture plate fixation.
    Methods: The medical records of all glaucoma patients who underwent AGV implantation surgery without plate fixation between 2009 and 2019 at the Sheba Medical Center (Tel Hashomer, Israel) were retrospectively reviewed. Clinical data on intraoperative and postoperative complications, best-corrected visual acuity, intraocular pressure, and number of intraocular pressure-lowering medications were retrieved.
    Results: Included were 95 eyes of 95 patients (53 men, 42 women; mean age, 54.9±17.5 y). The mean follow-up was 687±673 days. In total, 37 patients (37/95, 38.%) had AGV-related complications, of whom 28 (29.5%) required additional intervention. Women had a significantly higher rate of complications than men (21/42, 50% vs. 16/53, 30.2%, respectively, P=0.049). The 2 most common complications were AGV migration in 13 eyes (13.7%) and tube exposure/AGV extrusion in 9 eyes (9.5%). AGV was removed in 10 cases.
    Conclusions: In this cohort, omitting suture AGV plate fixation resulted in high rates of complications related to plate or tube movement, the need for further intervention, and AGV removal. Therefore, we cannot recommend this surgical technique.
    MeSH term(s) Adult ; Aged ; Female ; Follow-Up Studies ; Glaucoma/surgery ; Glaucoma Drainage Implants ; Humans ; Intraocular Pressure ; Male ; Middle Aged ; Prosthesis Implantation ; Retrospective Studies ; Sutures ; Treatment Outcome ; Visual Acuity
    Language English
    Publishing date 2021-01-15
    Publishing country United States
    Document type Journal Article
    ZDB-ID 913494-3
    ISSN 1536-481X ; 1057-0829
    ISSN (online) 1536-481X
    ISSN 1057-0829
    DOI 10.1097/IJG.0000000000001813
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

To top