  1. Article: Comparative Assessment of Sera from Individuals after S-Gene RNA-Based SARS-CoV-2 Vaccination with Spike-Protein-Based and Nucleocapsid-Based Serological Assays.

    Dörschug, Anja / Frickmann, Hagen / Schwanbeck, Julian / Yilmaz, Elif / Mese, Kemal / Hahn, Andreas / Groß, Uwe / Zautner, Andreas E

    Diagnostics (Basel, Switzerland)

    2021  Volume 11, Issue 3

    Abstract: Due to the beginning of vaccination against COVID-19, serological discrimination between vaccine-associated humoral response and serology-based surveillance of natural SARS-CoV-2 infections as well as breakthrough infections becomes an issue of relevance. ...

    Abstract Due to the beginning of vaccination against COVID-19, serological discrimination between vaccine-associated humoral response and serology-based surveillance of natural SARS-CoV-2 infections as well as breakthrough infections becomes an issue of relevance. Here, we assessed the differentiated effects of the application of an RNA vaccine using SARS-CoV-2 spike protein epitopes on the results of both anti-spike protein-based serology (EUROIMMUN) and anti-nucleocapsid-based serology (VIROTECH). A total of 80 serum samples from vaccinees acquired at different time points after vaccination was assessed. While positive or borderline serological response in the anti-spike protein assay was observed for all samples (90% both IgG and IgA, 6.3% IgA only, 3.8% borderline IgG only), only a single case of a falsely positive IgM was observed for the anti-nucleocapsid assay as expected due to this assay's specificity. Positive anti-spike protein antibodies were already detectable in the second week after the first dose of vaccination, with higher titers after the second dose of the vaccine. In conclusion, the combined application of anti-spike protein-based serology and anti-nucleocapsid-based serology will provide a useful option for the discrimination of vaccination response and natural infection.
    Language English
    Publishing date 2021-03-03
    Publishing country Switzerland
    Document type Journal Article
    ZDB-ID 2662336-5
    ISSN 2075-4418
    ISSN 2075-4418
    DOI 10.3390/diagnostics11030426
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  2. Article: Evaluation of the Xiamen AmonMed Biotechnology rapid diagnostic test COVID-19 IgM/IgG test kit (Colloidal gold).

    Dörschug, Anja / Schwanbeck, Julian / Hahn, Andreas / Hillebrecht, Anke / Blaschke, Sabine / Groß, Uwe / Heimesaat, Markus M / Frickmann, Hagen / Zautner, Andreas E

    European journal of microbiology & immunology

    2020  Volume 10, Issue 3, Page(s) 178–185

    Abstract: Introduction: To efficiently monitor the COVID-19 pandemic for surveillance purposes, reliable serological rapid diagnostic tests (RDTs) are desirable for settings where well-established high-throughput bench-top solutions are not available. Here, we ... ...

    Abstract Introduction: To efficiently monitor the COVID-19 pandemic for surveillance purposes, reliable serological rapid diagnostic tests (RDTs) are desirable for settings where well-established high-throughput bench-top solutions are not available. Here, we have evaluated such an RDT.
    Methods: We have assessed the Xiamen AmonMed Biotechnology COVID-19 IgM/IgG test kit (Colloidal gold) and the EUROIMMUN benchtop assay with serum samples from patients with polymerase chain reaction (PCR)-confirmed COVID-19 disease. Samples from patients with Epstein-Barr-virus (EBV) infection and blood donors were used for specificity testing.
    Results: For the colloid gold rapid test and the EUROIMMUN assay, the study indicated overall sensitivity of 15.2% and 67.4%, respectively, while specificity of 99.0% and 97.9% with the blood donor sera, as well as 100% and 96.8% with the EBV-patients, were observed, respectively. An association of the time period between positive PCR results and serum acquisition with serological test positivity could be observed for the immunologlobulin G subclass of the EUROIMMUN assay only.
    Conclusions: In spite of acceptable specificity of the assessed RDT, the detected poor sensitivity leaves room for improvement. The test results remain difficult to interpret and therefore the RDT can currently not be recommended for routine diagnostic or surveillance use.
    Keywords covid19
    Language English
    Publishing date 2020-09-25
    Publishing country Hungary
    Document type Journal Article
    ZDB-ID 2652327-9
    ISSN 2062-8633 ; 2062-509X
    ISSN (online) 2062-8633
    ISSN 2062-509X
    DOI 10.1556/1886.2020.00029
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  3. Article ; Online: Comparative Assessment of Sera from Individuals after S-Gene RNA-Based SARS-CoV-2 Vaccination with Spike-Protein-Based and Nucleocapsid-Based Serological Assays

    Anja Dörschug / Hagen Frickmann / Julian Schwanbeck / Elif Yilmaz / Kemal Mese / Andreas Hahn / Uwe Groß / Andreas E. Zautner

    Diagnostics, Vol 11, Iss 3, p

    2021  Volume 426

    Abstract: Due to the beginning of vaccination against COVID-19, serological discrimination between vaccine-associated humoral response and serology-based surveillance of natural SARS-CoV-2 infections as well as breakthrough infections becomes an issue of relevance. ...

    Abstract Due to the beginning of vaccination against COVID-19, serological discrimination between vaccine-associated humoral response and serology-based surveillance of natural SARS-CoV-2 infections as well as breakthrough infections becomes an issue of relevance. Here, we assessed the differentiated effects of the application of an RNA vaccine using SARS-CoV-2 spike protein epitopes on the results of both anti-spike protein–based serology (EUROIMMUN) and anti-nucleocapsid-based serology (VIROTECH). A total of 80 serum samples from vaccinees acquired at different time points after vaccination was assessed. While positive or borderline serological response in the anti-spike protein assay was observed for all samples (90% both IgG and IgA, 6.3% IgA only, 3.8% borderline IgG only), only a single case of a falsely positive IgM was observed for the anti-nucleocapsid assay as expected due to this assay’s specificity. Positive anti-spike protein antibodies were already detectable in the second week after the first dose of vaccination, with higher titers after the second dose of the vaccine. In conclusion, the combined application of anti-spike protein–based serology and anti-nucleocapsid-based serology will provide a useful option for the discrimination of vaccination response and natural infection.
    Keywords SARS-CoV-2 ; COVID-19 ; serology ; vaccination ; surveillance ; nucleocapsid ; Medicine (General) ; R5-920
    Subject code 570
    Language English
    Publishing date 2021-03-01T00:00:00Z
    Publisher MDPI AG
    Document type Article ; Online
    Database BASE - Bielefeld Academic Search Engine (life sciences selection)

    More links

    Kategorien

  4. Article: Comparison of Five Serological Assays for the Detection of SARS-CoV-2 Antibodies.

    Dörschug, Anja / Schwanbeck, Julian / Hahn, Andreas / Hillebrecht, Anke / Blaschke, Sabine / Mese, Kemal / Groß, Uwe / Dierks, Sascha / Frickmann, Hagen / Zautner, Andreas E

    Diagnostics (Basel, Switzerland)

    2021  Volume 11, Issue 1

    Abstract: Serological assays can contribute to the estimation of population proportions with previous immunologically relevant contact with the Severe Acute Respiratory Syndrome Corona Virus 2 (SARS-CoV-2) virus. In this study, we compared five commercially ... ...

    Abstract Serological assays can contribute to the estimation of population proportions with previous immunologically relevant contact with the Severe Acute Respiratory Syndrome Corona Virus 2 (SARS-CoV-2) virus. In this study, we compared five commercially available diagnostic assays for the diagnostic identification of SARS-CoV-2-specific antibodies. Depending on the assessed immunoglobulin subclass, recorded sensitivity ranged from 17.0% to 81.9% with best results for immunoglobulin G. Specificity with blood donor sera ranged from 90.2% to 100%, with sera from EBV patients it ranged from 84.3% to 100%. Agreement from fair to nearly perfect was recorded depending on the immunoglobulin class between the assays, the with best results being found for immunoglobulin G. Only for this immunoglobulin class was the association between later sample acquisition times (about three weeks after first positive PCR results) and positive serological results in COVID-19 patients confirmed. In conclusion, acceptable and comparable reliability for the assessed immunoglobulin G-specific assays could be shown, while there is still room for improvement regarding the reliability of the assays targeting the other immunoglobulin classes.
    Language English
    Publishing date 2021-01-06
    Publishing country Switzerland
    Document type Journal Article
    ZDB-ID 2662336-5
    ISSN 2075-4418
    ISSN 2075-4418
    DOI 10.3390/diagnostics11010078
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  5. Article: Evaluation of the Xiamen AmonMed Biotechnology rapid diagnostic test COVID-19 IgM/IgG test kit (Colloidal gold)

    Dörschug, Anja / Schwanbeck, Julian / Hahn, Andreas / Hillebrecht, Anke / Blaschke, Sabine / Groß, Uwe / Heimesaat, Markus M / Frickmann, Hagen / Zautner, Andreas E

    Abstract: Introduction: To efficiently monitor the COVID-19 pandemic for surveillance purposes, reliable serological rapid diagnostic tests (RDTs) are desirable for settings where well-established high-throughput bench-top solutions are not available. Here, we ... ...

    Abstract Introduction: To efficiently monitor the COVID-19 pandemic for surveillance purposes, reliable serological rapid diagnostic tests (RDTs) are desirable for settings where well-established high-throughput bench-top solutions are not available. Here, we have evaluated such an RDT. Methods: We have assessed the Xiamen AmonMed Biotechnology COVID-19 IgM/IgG test kit (Colloidal gold) and the EUROIMMUN benchtop assay with serum samples from patients with polymerase chain reaction (PCR)-confirmed COVID-19 disease. Samples from patients with Epstein-Barr-virus (EBV) infection and blood donors were used for specificity testing. Results: For the colloid gold rapid test and the EUROIMMUN assay, the study indicated overall sensitivity of 15.2% and 67.4%, respectively, while specificity of 99.0% and 97.9% with the blood donor sera, as well as 100% and 96.8% with the EBV-patients, were observed, respectively. An association of the time period between positive PCR results and serum acquisition with serological test positivity could be observed for the immunologlobulin G subclass of the EUROIMMUN assay only. Conclusions: In spite of acceptable specificity of the assessed RDT, the detected poor sensitivity leaves room for improvement. The test results remain difficult to interpret and therefore the RDT can currently not be recommended for routine diagnostic or surveillance use.
    Keywords covid19
    Publisher WHO
    Document type Article
    Note WHO #Covidence: #801161
    Database COVID19

    Kategorien

  6. Article ; Online: Comparison of Five Serological Assays for the Detection of SARS-CoV-2 Antibodies

    Anja Dörschug / Julian Schwanbeck / Andreas Hahn / Anke Hillebrecht / Sabine Blaschke / Kemal Mese / Uwe Groß / Sascha Dierks / Hagen Frickmann / Andreas E. Zautner

    Diagnostics, Vol 11, Iss 78, p

    2021  Volume 78

    Abstract: Serological assays can contribute to the estimation of population proportions with previous immunologically relevant contact with the Severe Acute Respiratory Syndrome Corona Virus 2 (SARS-CoV-2) virus. In this study, we compared five commercially ... ...

    Abstract Serological assays can contribute to the estimation of population proportions with previous immunologically relevant contact with the Severe Acute Respiratory Syndrome Corona Virus 2 (SARS-CoV-2) virus. In this study, we compared five commercially available diagnostic assays for the diagnostic identification of SARS-CoV-2-specific antibodies. Depending on the assessed immunoglobulin subclass, recorded sensitivity ranged from 17.0% to 81.9% with best results for immunoglobulin G. Specificity with blood donor sera ranged from 90.2% to 100%, with sera from EBV patients it ranged from 84.3% to 100%. Agreement from fair to nearly perfect was recorded depending on the immunoglobulin class between the assays, the with best results being found for immunoglobulin G. Only for this immunoglobulin class was the association between later sample acquisition times (about three weeks after first positive PCR results) and positive serological results in COVID-19 patients confirmed. In conclusion, acceptable and comparable reliability for the assessed immunoglobulin G-specific assays could be shown, while there is still room for improvement regarding the reliability of the assays targeting the other immunoglobulin classes.
    Keywords SARS-CoV-2 ; COVID-19 ; serology ; test comparison ; surveillance ; Medicine (General) ; R5-920
    Subject code 616
    Language English
    Publishing date 2021-01-01T00:00:00Z
    Publisher MDPI AG
    Document type Article ; Online
    Database BASE - Bielefeld Academic Search Engine (life sciences selection)

    More links

    Kategorien

  7. Article ; Online: High Proportion of SARS-CoV-2 RNA Persistence in IgG-Positive Patients with COVID-19

    Zautner, Andreas E. / Bauswein, Markus / Dörschug, Anja / Blaschk, Sabine / Lugert, Raimond / Ellenrieder, Volker / Meissner, Konrad / Moerer, Onnen / Hillebrecht, Anke / Gross, Uwe

    SSRN Electronic Journal ; ISSN 1556-5068

    2020  

    Keywords covid19
    Language English
    Publisher Elsevier BV
    Publishing country us
    Document type Article ; Online
    DOI 10.2139/ssrn.3605269
    Database BASE - Bielefeld Academic Search Engine (life sciences selection)

    More links