  1. Article: Ion chromatographic determination of sulfide and cyanide in real matrices by using pulsed amperometric detection on a silver electrode.

    Giuriati, Caterina / Cavalli, Silvano / Gorni, Alfredo / Badocco, Denis / Pastore, Paolo

    Journal of chromatography. A

    2004  Volume 1023, Issue 1, Page(s) 105–112

    Abstract: The determination of free sulfide and cyanide by pulsed amperometric detection (PAD) at a silver-working electrode was improved through a deep de-oxygenation (at least 10 min) of both standard and real solutions containing the two analytes and adopting a ...

    Abstract The determination of free sulfide and cyanide by pulsed amperometric detection (PAD) at a silver-working electrode was improved through a deep de-oxygenation (at least 10 min) of both standard and real solutions containing the two analytes and adopting a two-potential waveform able to eliminate Ag working electrode fouling. The waveform stepped around the oxidation of Ag in the presence of 0.1-0.4 M hydroxyl ion, from -0.1 to 0.1 V versus saturated calomel electrode (SCE). The eluent composition (0.4 M NaOH plus 7.5 mM oxalate solution) allowed a very good column efficiency and selectivity. The presence of a polysulfide species was hypothesized in sulfide solutions that had not been de-oxygenated and aged. The polysulfide eluted just before sulfide and was confirmed by a chemical test with SO3(2-) producing the elimination of the polysulfide peak. Detection limits, according to the Hubaux-Vos method, were 1.0 and 2.0 microg/l for S2- and CN , respectively. We demonstrated good performance of the optimized method by repeatedly injecting standard solutions and by analyzing different real matrices. The method exhibited very good accuracy and repeatability (10 microg/l and a 500 microl injection loop, had a repeatability better than 3% for sulfide and 100 microg/l had a repeatability better than 1% for cyanide). The two-potential waveform ensured long-term stability of the electrode surface that required no manual polishing procedure for at least 1 month (20 analysis per day).
    MeSH term(s) Chromatography, Liquid/methods ; Cyanides/analysis ; Electrochemistry/methods ; Electrodes ; Silver ; Sulfides/analysis
    Chemical Substances Cyanides ; Sulfides ; Silver (3M4G523W1G)
    Language English
    Publishing date 2004-01-09
    Publishing country Netherlands
    Document type Journal Article ; Research Support, Non-U.S. Gov't
    ZDB-ID 1171488-8
    ISSN 1873-3778 ; 0021-9673
    ISSN (online) 1873-3778
    ISSN 0021-9673
    DOI 10.1016/j.chroma.2003.10.001
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  2. Article: Ion chromatography applications in the determination of HF, HCl, NOx, SOx on stationary emissions.

    Giuriati, Caterina / Cristofori, Maria Cristina / Gorni, Alfredo / Abballe, Franco

    Annali dell'Istituto superiore di sanita

    2003  Volume 39, Issue 2, Page(s) 223–228

    Abstract: In this work, specific topics will be covered in order to verify an effective, routine application of ion chromatography as a suitable and approved technique for emission monitoring in the determination of HF, HCl, NOx and SOx on stationary emission. A ... ...

    Abstract In this work, specific topics will be covered in order to verify an effective, routine application of ion chromatography as a suitable and approved technique for emission monitoring in the determination of HF, HCl, NOx and SOx on stationary emission. A review of the analytical methods as proposed by recent updates in Italian environmental law and the problems encountered in the application of this method, such us the interference due to high level of carbonate, high hydroxides concentration particularly on SOx and NOx absorbing solution, are considered in the present work. The sample treatments before the IC analysis, this to reduce the matrix interference due to the strong basic solutions used to monitor different stationary emissions, are also examined. Some modifications in sampling are explored to find more suitable conditions for the IC analysis.
    MeSH term(s) Absorption ; Air Pollutants/analysis ; Chromatography, High Pressure Liquid/instrumentation ; Chromatography, High Pressure Liquid/methods ; Chromatography, Ion Exchange/instrumentation ; Chromatography, Ion Exchange/methods ; Environmental Monitoring/instrumentation ; Environmental Monitoring/legislation & jurisprudence ; Environmental Monitoring/methods ; Environmental Monitoring/standards ; Hydrochloric Acid/analysis ; Hydrofluoric Acid/analysis ; Hydrogen Peroxide ; Hydrogen-Ion Concentration ; Nitrogen Oxides/analysis ; Potassium Permanganate ; Sodium Hydroxide ; Solutions ; Sulfur Oxides/analysis
    Chemical Substances Air Pollutants ; Nitrogen Oxides ; Solutions ; Sulfur Oxides ; Potassium Permanganate (00OT1QX5U4) ; Sodium Hydroxide (55X04QC32I) ; Hydrogen Peroxide (BBX060AN9V) ; Hydrochloric Acid (QTT17582CB) ; Hydrofluoric Acid (RGL5YE86CZ)
    Language English
    Publishing date 2003
    Publishing country Italy
    Document type Comparative Study ; Journal Article ; Research Support, Non-U.S. Gov't
    ZDB-ID 950344-4
    ISSN 0021-2571
    ISSN 0021-2571
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

To top