Article ; Online: SU-E-J-148: Fabrication of an Anatomically Realistic Dynamic Respiratory Phantom.
2012 Volume 39, Issue 6Part8, Page(s) 3686–3687
Abstract: Purpose: The purpose of this project was to design an anatomically correct respiratory phantom that allows for accurate dose measurement within thoracic structures that move in a realistic fashion allowing for a more accurate simulation of in vivo ... ...
Abstract | Purpose: The purpose of this project was to design an anatomically correct respiratory phantom that allows for accurate dose measurement within thoracic structures that move in a realistic fashion allowing for a more accurate simulation of in vivo measurements. Methods: The basis for this phantom is The Dynamic Breathing Phantom (TBP), an Alderson Phantom by Radiology Support Devices (RSD). The phantom was disassembled, removing the proprietary pneumatic lung apparatus as well as the motor driven tumor mount. A CT of the phantom at rest in the exhale position was acquired with 0.25 cm slice thickness. Every sixteenth slice was printed out to scale. The lung cavity was segmented on the images. These were used to cut out 4.0 cm thick slabs of foam rubber matching the contour of the lung. These were assembled along with other thoracic structures manually imbedded in the foam rubber. The organs were then placed within the chest cavity of the phantom. A purpose-built diaphragm chamber made of a rubber bladder was inserted under the lung material. The manufacturer-provided air compressor system was re-tasked to drive the diaphragm chamber. Results: The foam rubber used as lung material has comparable density to human lung (-800 HU). The phantom is capable of producing realistic respiratory motion. This phantom will easily accommodate a variety of dosimeters and can be adapted for a variety of tumor/critical structure shapes, sizes and locations. Conclusions: The creation of this versatile humanoid phantom opens the door for a multitude of experiments to investigate dose to organs within the chest cavity for different planning techniques, under different respiratory condition, while using a more anatomically correct experimental setup. |
---|---|
Language | English |
Publishing date | 2012-06 |
Publishing country | United States |
Document type | Journal Article |
ZDB-ID | 188780-4 |
ISSN | 2473-4209 ; 0094-2405 |
ISSN (online) | 2473-4209 |
ISSN | 0094-2405 |
DOI | 10.1118/1.4734985 |
Database | MEDical Literature Analysis and Retrieval System OnLINE |
Full text online
More links
Kategorien
In stock of ZB MED Cologne/Königswinter
Zs.A 1210: Show issues | Location: Je nach Verfügbarkeit (siehe Angabe bei Bestand) bis Jg. 1994: Bestellungen von Artikeln über das Online-Bestellformular Jg. 1995 - 2021: Lesesall (1.OG) ab Jg. 2022: Lesesaal (EG) |
Order via subito
This service is chargeable due to the Delivery terms set by subito. Orders including an article and supplementary material will be classified as separate orders. In these cases, fees will be demanded for each order.