LIVIVO - The Search Portal for Life Sciences

zur deutschen Oberfläche wechseln
Advanced search

Search results

Result 1 - 10 of total 3126

Search options

  1. Article: Analytical evaluation of the novel Lumipulse G BRAHMS procalcitonin immunoassay.

    Ruzzenente, Orazio / Salvagno, Gian Luca / Gelati, Matteo / Lippi, Giuseppe

    Practical laboratory medicine

    2016  Volume 6, Page(s) 8–13

    Abstract: ... G BRAHMS PCT]=0.76×[Vidas BRAHMS PCT]+0.04. The mean overall bias of Lumipulse G BRAHMS PCT versus ... Conclusions: These results attest that Lumipulse G BRAHMS PCT exhibits excellent analytical performance ...

    Abstract Objectives: This study was designed to evaluate the analytical performance of the novel Lumipulse G1200 BRAHMS procalcitonin (PCT) immunoassay.
    Design and methods: This analytical evaluation encompassed the calculation of the limit of blank (LOB), limit of detection (LOD), functional sensitivity, intra- and inter-assay imprecision, confirmation of linearity and a comparison with the Vidas BRAHMS PCT assay.
    Results: The LOB, LOD and functional sensitivity were 0.0010 ng/mL, 0.0016 ng/mL and 0.008 ng/mL, respectively. The total analytical imprecision was found to be 2.1% and the linearity was excellent (r=1.00) in the range of concentrations between 0.006-75.5 ng/mL. The correlation coefficient with Vidas BRAHMS PCT was 0.995 and the equation of the Passing and Bablok regression analysis was [Lumipulse G BRAHMS PCT]=0.76×[Vidas BRAHMS PCT]+0.04. The mean overall bias of Lumipulse G BRAHMS PCT versus Vidas BRAHMS PCT was -3.03 ng/mL (95% confidence interval [CI]: -4.32 to -1.74 ng/mL), whereas the mean bias in samples with PCT concentration between 0-10 ng/mL was -0.49 ng/mL (95% CI: -0.77 to -0.24 ng/mL). The diagnostic agreement was 100% at 0.5 ng/mL, 97% at 2.0 ng/mL and 95% at 10 ng/mL, respectively.
    Conclusions: These results attest that Lumipulse G BRAHMS PCT exhibits excellent analytical performance, among the best of the methods currently available on the diagnostic market. However, the significant bias compared to the Vidas BRAHMS PCT suggests that the methods cannot be used interchangeably.
    Language English
    Publishing date 2016-07-16
    Publishing country Netherlands
    Document type Journal Article
    ZDB-ID 2834973-8
    ISSN 2352-5517
    ISSN 2352-5517
    DOI 10.1016/j.plabm.2016.07.001
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  2. Article ; Online: SARS-CoV-2 self-testing: Handle with care.

    Lippi, Giuseppe

    Infection, disease & health

    2024  Volume 29, Issue 2, Page(s) 112–113

    MeSH term(s) Humans ; SARS-CoV-2 ; COVID-19 ; COVID-19 Testing ; Clinical Laboratory Techniques
    Language English
    Publishing date 2024-02-10
    Publishing country Netherlands
    Document type Letter
    ZDB-ID 2902143-1
    ISSN 2468-0869 ; 2468-0451
    ISSN (online) 2468-0869
    ISSN 2468-0451
    DOI 10.1016/j.idh.2023.12.002
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  3. Article ; Online: Age standardized mortality in US children during the first two years of the COVID-19 pandemic.

    Lippi, Giuseppe

    European journal of pediatrics

    2024  

    Language English
    Publishing date 2024-04-22
    Publishing country Germany
    Document type Letter
    ZDB-ID 194196-3
    ISSN 1432-1076 ; 0340-6199 ; 0943-9676
    ISSN (online) 1432-1076
    ISSN 0340-6199 ; 0943-9676
    DOI 10.1007/s00431-024-05582-8
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  4. Article ; Online: Analytical evaluation of the novel Lumipulse G BRAHMS procalcitonin immunoassay

    Orazio Ruzzenente / Gian Luca Salvagno / Matteo Gelati / Giuseppe Lippi

    Practical Laboratory Medicine, Vol 6, Iss , Pp 8-

    2016  Volume 13

    Abstract: ... the equation of the Passing and Bablok regression analysis was [Lumipulse G BRAHMS PCT]=0.76×[Vidas BRAHMS PCT ... 0.04. The mean overall bias of Lumipulse G BRAHMS PCT versus Vidas BRAHMS PCT was −3.03 ng/mL (95 ... G BRAHMS PCT exhibits excellent analytical performance, among the best of the methods currently ...

    Abstract Objectives: This study was designed to evaluate the analytical performance of the novel Lumipulse G1200 BRAHMS procalcitonin (PCT) immunoassay. Design and methods: This analytical evaluation encompassed the calculation of the limit of blank (LOB), limit of detection (LOD), functional sensitivity, intra- and inter-assay imprecision, confirmation of linearity and a comparison with the Vidas BRAHMS PCT assay. Results: The LOB, LOD and functional sensitivity were 0.0010 ng/mL, 0.0016 ng/mL and 0.008 ng/mL, respectively. The total analytical imprecision was found to be 2.1% and the linearity was excellent (r=1.00) in the range of concentrations between 0.006–75.5 ng/mL. The correlation coefficient with Vidas BRAHMS PCT was 0.995 and the equation of the Passing and Bablok regression analysis was [Lumipulse G BRAHMS PCT]=0.76×[Vidas BRAHMS PCT]+0.04. The mean overall bias of Lumipulse G BRAHMS PCT versus Vidas BRAHMS PCT was −3.03 ng/mL (95% confidence interval [CI]: −4.32 to −1.74 ng/mL), whereas the mean bias in samples with PCT concentration between 0–10 ng/mL was −0.49 ng/mL (95% CI: −0.77 to −0.24 ng/mL). The diagnostic agreement was 100% at 0.5 ng/mL, 97% at 2.0 ng/mL and 95% at 10 ng/mL, respectively. Conclusions: These results attest that Lumipulse G BRAHMS PCT exhibits excellent analytical performance, among the best of the methods currently available on the diagnostic market. However, the significant bias compared to the Vidas BRAHMS PCT suggests that the methods cannot be used interchangeably. Keywords: Sepsis, Infection, Procalcitonin, Immunoassay
    Keywords Medicine (General) ; R5-920 ; Chemistry ; QD1-999
    Subject code 630
    Language English
    Publishing date 2016-12-01T00:00:00Z
    Publisher Elsevier
    Document type Article ; Online
    Database BASE - Bielefeld Academic Search Engine (life sciences selection)

    More links

    Kategorien

  5. Article ; Online: The impact of COVID-19 on citations of laboratory medicine journals.

    Lippi, Giuseppe

    Clinical chemistry and laboratory medicine

    2022  Volume 61, Issue 5, Page(s) 954–956

    MeSH term(s) Humans ; COVID-19 ; Periodicals as Topic ; Laboratories
    Language English
    Publishing date 2022-11-22
    Publishing country Germany
    Document type Letter
    ZDB-ID 1418007-8
    ISSN 1437-4331 ; 1434-6621 ; 1437-8523
    ISSN (online) 1437-4331
    ISSN 1434-6621 ; 1437-8523
    DOI 10.1515/cclm-2022-1159
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  6. Article ; Online: Potential drawbacks of SARS-CoV-2 seroprevalence surveys.

    Lippi, G

    The Journal of hospital infection

    2020  Volume 110, Page(s) 206

    MeSH term(s) Antibodies, Viral ; COVID-19 ; Health Personnel ; Humans ; SARS-CoV-2 ; Seroepidemiologic Studies
    Chemical Substances Antibodies, Viral
    Language English
    Publishing date 2020-12-21
    Publishing country England
    Document type Letter ; Comment
    ZDB-ID 779366-2
    ISSN 1532-2939 ; 0195-6701
    ISSN (online) 1532-2939
    ISSN 0195-6701
    DOI 10.1016/j.jhin.2020.12.011
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  7. Article ; Online: Historical Comparison Between the Death Rate for Spanish Flu and Coronavirus Disease 2019 in Italy.

    Mattiuzzi, Camilla / Lippi, Giuseppe

    The Journal of infectious diseases

    2024  

    Language English
    Publishing date 2024-04-10
    Publishing country United States
    Document type Journal Article
    ZDB-ID 3019-3
    ISSN 1537-6613 ; 0022-1899
    ISSN (online) 1537-6613
    ISSN 0022-1899
    DOI 10.1093/infdis/jiae115
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  8. Article ; Online: Evidence of concerning decline of COVID-19 vaccination in older persons.

    Mattiuzzi, Camilla / Lippi, Giuseppe

    Immunologic research

    2024  

    Language English
    Publishing date 2024-01-26
    Publishing country United States
    Document type Letter
    ZDB-ID 632857-x
    ISSN 1559-0755 ; 0257-277X
    ISSN (online) 1559-0755
    ISSN 0257-277X
    DOI 10.1007/s12026-024-09460-1
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  9. Article ; Online: Are there any reasons to use three levels of quality control materials instead of two and if so, what are the arguments?

    Sonntag, Oswald / Lippi, Giuseppe

    Clinical chemistry and laboratory medicine

    2024  

    Language English
    Publishing date 2024-03-29
    Publishing country Germany
    Document type Letter
    ZDB-ID 1418007-8
    ISSN 1437-4331 ; 1434-6621 ; 1437-8523
    ISSN (online) 1437-4331
    ISSN 1434-6621 ; 1437-8523
    DOI 10.1515/cclm-2024-0303
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  10. Article ; Online: Cardiac troponin T (cTnT) assessment using incompletely filled K2EDTA blood tubes is reliable.

    Lippi, Giuseppe / Salvagno, Gian Luca

    Einstein (Sao Paulo, Brazil)

    2024  Volume 22, Page(s) eCE0613

    MeSH term(s) Humans ; Troponin T ; Myocardium ; Biomarkers
    Chemical Substances Troponin T ; Biomarkers
    Language English
    Publishing date 2024-02-05
    Publishing country Brazil
    Document type Letter
    ZDB-ID 2418293-X
    ISSN 2317-6385 ; 2317-6385
    ISSN (online) 2317-6385
    ISSN 2317-6385
    DOI 10.31744/einstein_journal/2024CE0613
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

To top