Article ; Online: Anterior Segment Biometry During Accommodation After Posterior Chamber Phakic Implantable Collamer Lens Implantation.
Journal of refractive surgery (Thorofare, N.J. : 1995)
2024 Volume 40, Issue 3, Page(s) e164–e172
Abstract: Purpose: To evaluate the dynamic changes in anterior segment parameters during accommodation following Implantable Collamer Lens (ICL) implantation with swept-source optical coherence tomography (SS-OCT).: Methods: Under the accommodation of 0.00 ... ...
Abstract | Purpose: To evaluate the dynamic changes in anterior segment parameters during accommodation following Implantable Collamer Lens (ICL) implantation with swept-source optical coherence tomography (SS-OCT). Methods: Under the accommodation of 0.00 diopters (D), 3.00 D, and maximum amplitude, SS-OCT was used to examine the anterior segment parameters, including ICL vault, ICL depth (the distance between the corneal endothelium and the posterior surface of ICL), crystalline lens thickness, anterior chamber depth, and various parameters of the anterior chamber angle, comprising angle opening distance, angle recess area, trabecular iris space area, and trabecular iris angle. Results: During accommodation, the ICL vault showed a significant decrease from baseline (536 ± 278 μm) to 3.00 D (522 ± 281 μm), followed by an increase from 3.00 D to maximum amplitude (548 ± 306 μm) (analysis of variance [ANOVA], Conclusions: The anterior segment, including ICL vault and anterior chamber angle, undergo significant dynamic changes during accommodation. These accommodative changes may require careful monitoring for the surgery design of ICL implantation. [ |
---|---|
MeSH term(s) | Humans ; Lens Implantation, Intraocular/methods ; Phakic Intraocular Lenses ; Myopia/surgery ; Accommodation, Ocular ; Anterior Chamber/diagnostic imaging ; Pseudophakia/surgery ; Tomography, Optical Coherence ; Biometry ; Lens, Crystalline |
Language | English |
Publishing date | 2024-03-01 |
Publishing country | United States |
Document type | Journal Article |
ZDB-ID | 1264796-2 |
ISSN | 1938-2391 ; 0883-0444 ; 1081-597X ; 1081-0803 |
ISSN (online) | 1938-2391 |
ISSN | 0883-0444 ; 1081-597X ; 1081-0803 |
DOI | 10.3928/1081597X-20240212-01 |
Database | MEDical Literature Analysis and Retrieval System OnLINE |
More links
Kategorien
In stock of ZB MED Cologne/Königswinter
Zs.A 3248: Show issues | Location: Je nach Verfügbarkeit (siehe Angabe bei Bestand) bis Jg. 1994: Bestellungen von Artikeln über das Online-Bestellformular Jg. 1995 - 2021: Lesesall (2.OG) ab Jg. 2022: Lesesaal (EG) |
|||
Zs.MO 289: Show issues |
Order via subito
This service is chargeable due to the Delivery terms set by subito. Orders including an article and supplementary material will be classified as separate orders. In these cases, fees will be demanded for each order.