Article ; Online: A Semi-Automatic Environmental Monitoring Device for Mercury and Cobalt Ion Detection.
Small (Weinheim an der Bergstrasse, Germany)
2023 Volume 20, Issue 8, Page(s) e2303871
Abstract: A syringe-based, semi-automatic environmental monitoring device is developed for on-site detection of harmful heavy metal ions in water. This portable device consists of a spring-embedded syringe and a polydimethylsiloxane (PDMS) membrane-based flow ... ...
Abstract | A syringe-based, semi-automatic environmental monitoring device is developed for on-site detection of harmful heavy metal ions in water. This portable device consists of a spring-embedded syringe and a polydimethylsiloxane (PDMS) membrane-based flow regulator for semi-automatic fix-and-release fluidic valve actuation, and a paper-based analytical device (PAD) with two kinds of gold nanoclusters (AuNCs) for sensitive Hg |
---|---|
Language | English |
Publishing date | 2023-10-10 |
Publishing country | Germany |
Document type | Journal Article |
ZDB-ID | 2168935-0 |
ISSN | 1613-6829 ; 1613-6810 |
ISSN (online) | 1613-6829 |
ISSN | 1613-6810 |
DOI | 10.1002/smll.202303871 |