LIVIVO - Das Suchportal für Lebenswissenschaften

switch to English language
Erweiterte Suche

Ihre letzten Suchen

  1. AU="Akala, Isiaka Olusola"
  2. AU="Nicolás Gonzalo Núñez"
  3. AU="Hernández Solis, Alejandro"
  4. AU="Jadad, Alejandro R"
  5. AU="Lastres, Palma Rico" AU="Lastres, Palma Rico"
  6. AU="Manes, K"
  7. AU="Baugh, Matthew"
  8. AU="Qu, C"
  9. AU="Flett, Heather"
  10. AU="Shueh Lin Lim"
  11. AU="Schröder, Johann"
  12. AU=Butler Taylor
  13. AU="Yang, Fan"
  14. AU="Giacomo Frati"
  15. AU=Kokhaei P
  16. AU="Charikleia Triantopoulou"
  17. AU="Salil Bhargava"
  18. AU="Jong-Eun Lee"
  19. AU="Vargas C, Laura"

Suchergebnis

Treffer 1 - 1 von insgesamt 1

Suchoptionen

Artikel ; Online: Chest X-rays of newborns in a medical facility: variation between the entrance skin dose measurements using the indirect and direct methods for clinical dose audit.

Omojola, Akintayo Daniel / Akpochafor, Michael Onoriode / Adeneye, Samuel Olaolu / Akala, Isiaka Olusola / Agboje, Azuka Anthonio

Japanese journal of radiology

2021  Band 40, Heft 2, Seite(n) 219–225

Abstract: Purpose: This study aims to determine the mean and 75th percentile entrance skin dose (ESD: Materials and methods: The study determined the digital radiography (DR) X-ray machine output using a calibrated XR Multidetector (silicon photodiode). X-ray ... ...

Abstract Purpose: This study aims to determine the mean and 75th percentile entrance skin dose (ESD
Materials and methods: The study determined the digital radiography (DR) X-ray machine output using a calibrated XR Multidetector (silicon photodiode). X-ray machine milliampere-seconds (mAs), peak kilovoltage (kVp), focus to detector distance (FDD) and focus to skin distance (FSD) were used from a previous study. The mean kVp and mAs were 56.63 (52-60) and 5.7 (5-6.3) and the patient thickness was 9.5 (8-11.5) cm.
Results: The mean ESDs of the newborn between 0 and 28 days were 0.67 ± 0.09 mGy, and the 75th percentile was 0.75 mGy. The effective dose (E) for the 40 patients was 0.19 mSv and the estimated prenatal cancer risk ranged from (5-24.7) 10
Conclusion: The 75th percentile ESD was the highest compared to the American College of Radiology-American Association of Physicists in Medicine-Society for Pediatric Radiology (ACR-AAPM-SPR), European Commission (EC) and United Kingdom (UK) reports. Comparison of both methods for assessing ESD was within 40% as compared to other studies. Based on the above results, the indirect method can be implemented for clinical dose audit.
Mesh-Begriff(e) Child ; Humans ; Infant, Newborn ; Radiation Dosage ; Radiographic Image Enhancement ; Radiography ; Skin ; X-Rays
Sprache Englisch
Erscheinungsdatum 2021-09-07
Erscheinungsland Japan
Dokumenttyp Journal Article
ZDB-ID 2488907-6
ISSN 1867-108X ; 1867-1071
ISSN (online) 1867-108X
ISSN 1867-1071
DOI 10.1007/s11604-021-01193-7
Signatur
Zs.A 2249: Hefte anzeigen Standort:
Je nach Verfügbarkeit (siehe Angabe bei Bestand)
bis Jg. 1994: Bestellungen von Artikeln über das Online-Bestellformular
Jg. 1995 - 2021: Lesesall (1.OG)
ab Jg. 2022: Lesesaal (EG)
Datenquelle MEDical Literature Analysis and Retrieval System OnLINE

Zusatzmaterialien

Kategorien

Zum Seitenanfang