Article ; Online: Point-of-care impedimetric aptasensor to detect the luteinizing hormone.
2024 Volume 191, Issue 2, Page(s) 115
Abstract: Luteinizing hormone (LH) is a useful biomarker for identifying ovulation events in the cows to predict the time of ovulation to achieve a high success rate of conception following artificial insemination. Although antibody-based radioimmunoassay and ... ...
Abstract | Luteinizing hormone (LH) is a useful biomarker for identifying ovulation events in the cows to predict the time of ovulation to achieve a high success rate of conception following artificial insemination. Although antibody-based radioimmunoassay and enzyme-linked immunosorbent assay are being used for LH measurement, these techniques are expensive, time-consuming, and require expertise and sophisticated laboratory facilities. So, there is a need for a field-applicable, affordable, easy-to-use method for LH detection. For developing such a specific, quantitative, and inexpensive system, an aptamer-based smartphone-enabled aptasensor has been investigated. The aptamer was used instead of the antibody as a biorecognition element due to its comparative stability at ambient temperature, ease of synthesis, and cost-effectiveness. Electrochemical impedance spectroscopy has been used to obtain label-free detection of LH within 20 min in ~ 20 μL sample volume. The screen-printed gold electrode is compatible with a smartphone-enabled miniaturized device (Sensit Smart; Palmsens BV, The Netherlands) and was fabricated with the aptamer to detect LH in biological fluids (limit of detection 0.80 and 0.61 ng/mL in buffer and undiluted/unprocessed serum, respectively, with the dynamic range of detection of 0.01 to 50 ng/mL). All the data were obtained in the 10 kHz to 0.10 Hz frequency range at a bias potential of 0.30 V with an alternating potential of 10 mV. The clinical relevance of the sensor was evaluated in 10 serum samples collected from dairy animals which established a high correlation with standard LH-ELISA (κ > 0.87). The aptasensor can be stored at room temperature for 30 days without any significant loss in electrochemical sensing ability. |
---|---|
MeSH term(s) | Animals ; Cattle ; Luteinizing Hormone ; Point-of-Care Systems ; Aptamers, Nucleotide/chemistry ; Biosensing Techniques/methods ; Electrochemical Techniques/methods |
Chemical Substances | Luteinizing Hormone (9002-67-9) ; Aptamers, Nucleotide |
Language | English |
Publishing date | 2024-01-30 |
Publishing country | Austria |
Document type | Journal Article ; Research Support, Non-U.S. Gov't |
ZDB-ID | 89-9 |
ISSN | 1436-5073 ; 0026-3672 |
ISSN (online) | 1436-5073 |
ISSN | 0026-3672 |
DOI | 10.1007/s00604-024-06191-w |
Database | MEDical Literature Analysis and Retrieval System OnLINE |
Full text online
More links
Kategorien
In stock of ZB MED Bonn / Germany
Z 56/171: Show issues | ||||
Z 8.1: Show issues |
Order via subito
This service is chargeable due to the Delivery terms set by subito. Orders including an article and supplementary material will be classified as separate orders. In these cases, fees will be demanded for each order.
Inter-library loan at ZB MED
Your chosen title can be delivered directly to ZB MED Cologne location if you are registered as a user at ZB MED Cologne.