LIVIVO - The Search Portal for Life Sciences

zur deutschen Oberfläche wechseln
Advanced search

Search results

Result 1 - 6 of total 6

Search options

  1. Article ; Online: Update on the Utility of Optical Coherence Tomography in the Analysis of the Optic Nerve Head in Highly Myopic Eyes with and without Glaucoma

    Bachar Kudsieh / José Ignacio Fernández-Vigo / Ignacio Flores-Moreno / Jorge Ruiz-Medrano / Maria Garcia-Zamora / Muhsen Samaan / Jose Maria Ruiz-Moreno

    Journal of Clinical Medicine, Vol 12, Iss 2592, p

    2023  Volume 2592

    Abstract: Glaucoma diagnosis in highly myopic subjects by optic nerve head (ONH) imaging is challenging as it is difficult to distinguish structural defects related to glaucoma from myopia-related defects in these subjects. Optical coherence tomography (OCT) has ... ...

    Abstract Glaucoma diagnosis in highly myopic subjects by optic nerve head (ONH) imaging is challenging as it is difficult to distinguish structural defects related to glaucoma from myopia-related defects in these subjects. Optical coherence tomography (OCT) has evolved to become a routine examination at present, providing key information in the assessment of glaucoma based on the study of the ONH. However, the correct segmentation and interpretation of the ONH data employing OCT is still a challenge in highly myopic patients. High-resolution OCT images can help qualitatively and quantitatively describe the structural characteristics and anatomical changes in highly myopic subjects with and without glaucoma. The ONH and peripapillary area can be analyzed to measure the myopic atrophic-related zone, the existence of intrachoroidal cavitation, staphyloma, and ONH pits by OCT. Similarly, the lamina cribosa observed in the OCT images may reveal anatomical changes that justify visual defects. Several quantitative parameters of the ONH obtained from OCT images were proposed to predict the progression of visual defects in glaucoma subjects. Additionally, OCT images help identify factors that may negatively influence the measurement of the retinal nerve fiber layer (RNFL) and provide better analysis using new parameters, such as Bruch’s Membrane Opening-Minimum Rim Width, which serves as an alternative to RNFL measurements in highly myopic subjects due to its superior diagnostic ability.
    Keywords optic nerve head ; high myopia ; myopic glaucoma ; optical coherence tomography ; peripapillary atrophy ; optic disc tilt ; Medicine ; R
    Language English
    Publishing date 2023-03-01T00:00:00Z
    Publisher MDPI AG
    Document type Article ; Online
    Database BASE - Bielefeld Academic Search Engine (life sciences selection)

    More links

    Kategorien

  2. Article ; Online: MLIP genotype as a predictor of pharmacological response in primary open-angle glaucoma and ocular hypertension

    María I. Canut / Olaya Villa / Bachar Kudsieh / Heidi Mattlin / Isabel Banchs / Juan R. González / Lluís Armengol / Ricardo P. Casaroli-Marano

    Scientific Reports, Vol 11, Iss 1, Pp 1-

    2021  Volume 9

    Abstract: Abstract Predicting the therapeutic response to ocular hypotensive drugs is crucial for the clinical treatment and management of glaucoma. Our aim was to identify a possible genetic contribution to the response to current pharmacological treatments of ... ...

    Abstract Abstract Predicting the therapeutic response to ocular hypotensive drugs is crucial for the clinical treatment and management of glaucoma. Our aim was to identify a possible genetic contribution to the response to current pharmacological treatments of choice in a white Mediterranean population with primary open-angle glaucoma (POAG) or ocular hypertension (OH). We conducted a prospective, controlled, randomized, partial crossover study that included 151 patients of both genders, aged 18 years and older, diagnosed with and requiring pharmacological treatment for POAG or OH in one or both eyes. We sought to identify copy number variants (CNVs) associated with differences in pharmacological response, using a DNA pooling strategy of carefully phenotyped treatment responders and non-responders, treated for a minimum of 6 weeks with a beta-blocker (timolol maleate) and/or prostaglandin analog (latanoprost). Diurnal intraocular pressure reduction and comparative genome wide CNVs were analyzed. Our finding that copy number alleles of an intronic portion of the MLIP gene is a predictor of pharmacological response to beta blockers and prostaglandin analogs could be used as a biomarker to guide first-tier POAG and OH treatment. Our finding improves understanding of the genetic factors modulating pharmacological response in POAG and OH, and represents an important contribution to the establishment of a personalized approach to the treatment of glaucoma.
    Keywords Medicine ; R ; Science ; Q
    Subject code 610
    Language English
    Publishing date 2021-01-01T00:00:00Z
    Publisher Nature Portfolio
    Document type Article ; Online
    Database BASE - Bielefeld Academic Search Engine (life sciences selection)

    More links

    Kategorien

  3. Article ; Online: Publisher Correction

    María I. Canut / Olaya Villa / Bachar Kudsieh / Heidi Mattlin / Isabel Banchs / Juan R. González / Lluís Armengol / Ricardo P. Casaroli‑Marano

    Scientific Reports, Vol 11, Iss 1, Pp 1-

    MLIP genotype as a predictor of pharmacological response in primary open-angle glaucoma and ocular hypertension

    2021  Volume 1

    Abstract: An amendment to this paper has been published and can be accessed via a link at the top of the paper. ...

    Abstract An amendment to this paper has been published and can be accessed via a link at the top of the paper.
    Keywords Medicine ; R ; Science ; Q
    Language English
    Publishing date 2021-04-01T00:00:00Z
    Publisher Nature Portfolio
    Document type Article ; Online
    Database BASE - Bielefeld Academic Search Engine (life sciences selection)

    More links

    Kategorien

  4. Article ; Online: New applanation tonometer for myopic patients after laser refractive surgery

    María Iglesias / Francisco Yebra / Bachar Kudsieh / Andrea Laiseca / Cristina Santos / Jeroni Nadal / Rafael Barraquer / Ricardo P. Casaroli-Marano

    Scientific Reports, Vol 10, Iss 1, Pp 1-

    2020  Volume 12

    Abstract: Abstract This study assesses the agreement between intraocular pressure (IOP) measurements taken with the Goldmann applanation tonometer (GAT) and a new experimental applanation tonometer with a convexly shaped apex (CT) after laser myopic refractive ... ...

    Abstract Abstract This study assesses the agreement between intraocular pressure (IOP) measurements taken with the Goldmann applanation tonometer (GAT) and a new experimental applanation tonometer with a convexly shaped apex (CT) after laser myopic refractive surgery. Two different CT radii (CT1 and CT2) were designed with a finite element analyser, and a prospective double masked study on 102 eyes from 102 patients was carried out. A Bland-Altman plot and intra-class correlation coefficient (ICC) were calculated to assess the agreement between GAT measurements and the measurements of both CT1 and CT2 before and after myopic laser assisted in situ keratomileusis (LASIK; n = 73) and photorefractive keratectomy (PRK; n = 29). We evaluated a subset of two subgroups (n = 36 each) for intra and inter-observer (IA/IE) error. From the whole cohort, the best IOP agreement was observed between GATpre and CT1post surgery: 16.09 ± 2.92 vs 16.42 ± 2.87 (p < 0.001); ICC = 0.675 (95% CI: 0.554–0.768). In the analysis of LASIK vs PRK, GATpre and CT1post showed the highest agreement, although LASIK measurements were more accurate than PRK, as the ICC = 0.718 (95% CI: 0.594–0.812) and ICC = 0.578 (95% CI: 0.182–0.795) respectively. Excellent agreement was observed for IA/IE, and there was an ICC > 0.8 (95% CI) in all cases. CT1 proved more accurate in the LASIK subgroup. In conclusion, our new version of GAT could be used with post-surgery LASIK patients as a more accurate measurement device compared to the current reference tonometer.
    Keywords Medicine ; R ; Science ; Q
    Subject code 616
    Language English
    Publishing date 2020-04-01T00:00:00Z
    Publisher Nature Publishing Group
    Document type Article ; Online
    Database BASE - Bielefeld Academic Search Engine (life sciences selection)

    More links

    Kategorien

  5. Article ; Online: Numerical model to predict and compare the hypotensive efficacy and safety of minimally invasive glaucoma surgery devices.

    Bachar Kudsieh / Jose Ignacio Fernández-Vigo / Rafael Agujetas / Jose María Montanero / Jose María Ruiz-Moreno / Jose Ángel Fernández-Vigo / Julián García-Feijóo

    PLoS ONE, Vol 15, Iss 9, p e

    2020  Volume 0239324

    Abstract: Purpose To predict and compare the hypotensive efficacy of three minimally-invasive glaucoma surgery (MIGS) implants through a numerical model. Methods Post-implant hypotensive efficacy was evaluated by using a numerical model and a computational fluid ... ...

    Abstract Purpose To predict and compare the hypotensive efficacy of three minimally-invasive glaucoma surgery (MIGS) implants through a numerical model. Methods Post-implant hypotensive efficacy was evaluated by using a numerical model and a computational fluid dynamics simulation. Three different devices were compared: the XEN 45 stent (tube diameter, 45 μm), the XEN 63 stent (63 μm) and the PreserFlo microshunt (70 μm). The influence of the filtration bleb pressure (Bp) and tube diameter, length, and position within the anterior chamber (AC) on intraocular pressure (IOP) were evaluated. Results Using baseline IOPs of 25, 30 and 50 mmHg, respectively, the corresponding computed post-implant IOPs for each device were as follows: XEN 45: 17 mmHg (29% decrease), 19 mmHg (45%) and 20 mmHg (59%) respectively; XEN 63: 13 mmHg (48%), 13 mmHg (62%), and 13 mmHg (73%); PreserFlo: 12 mmHg (59%), 13 mmHg (73%) and 13 mmHg (73%). At a baseline IOP of 35 mmHg with an increase in the outflow resistance within the Bp from 5 to 17 mmHg, the hypotensive efficacy for each device was reduced as follows: XEN45: 54% to 37%; XEN 63: 74% to 46%; and PreserFlo: 75% to 47%. The length and the position of the tube in the AC had only a minimal (non-significant) effect on IOP (<0.1 mmHg). Conclusions This hydrodynamic/numerical model showed that implant diameter and bleb pressure are the two most pertinent determinants of hypotensive efficacy. In distinction, tube length and position in the AC do not significantly influence IOP.
    Keywords Medicine ; R ; Science ; Q
    Subject code 621
    Language English
    Publishing date 2020-01-01T00:00:00Z
    Publisher Public Library of Science (PLoS)
    Document type Article ; Online
    Database BASE - Bielefeld Academic Search Engine (life sciences selection)

    More links

    Kategorien

  6. Article ; Online: Numerical model to predict and compare the hypotensive efficacy and safety of minimally invasive glaucoma surgery devices

    Bachar Kudsieh / Jose Ignacio Fernández-Vigo / Rafael Agujetas / Jose María Montanero / Jose María Ruiz-Moreno / Jose Ángel Fernández-Vigo / Julián García-Feijóo / Ahmed Awadein

    PLoS ONE, Vol 15, Iss

    2020  Volume 9

    Abstract: Purpose To predict and compare the hypotensive efficacy of three minimally-invasive glaucoma surgery (MIGS) implants through a numerical model. Methods Post-implant hypotensive efficacy was evaluated by using a numerical model and a computational fluid ... ...

    Abstract Purpose To predict and compare the hypotensive efficacy of three minimally-invasive glaucoma surgery (MIGS) implants through a numerical model. Methods Post-implant hypotensive efficacy was evaluated by using a numerical model and a computational fluid dynamics simulation. Three different devices were compared: the XEN 45 stent (tube diameter, 45 μm), the XEN 63 stent (63 μm) and the PreserFlo microshunt (70 μm). The influence of the filtration bleb pressure (Bp) and tube diameter, length, and position within the anterior chamber (AC) on intraocular pressure (IOP) were evaluated. Results Using baseline IOPs of 25, 30 and 50 mmHg, respectively, the corresponding computed post-implant IOPs for each device were as follows: XEN 45: 17 mmHg (29% decrease), 19 mmHg (45%) and 20 mmHg (59%) respectively; XEN 63: 13 mmHg (48%), 13 mmHg (62%), and 13 mmHg (73%); PreserFlo: 12 mmHg (59%), 13 mmHg (73%) and 13 mmHg (73%). At a baseline IOP of 35 mmHg with an increase in the outflow resistance within the Bp from 5 to 17 mmHg, the hypotensive efficacy for each device was reduced as follows: XEN45: 54% to 37%; XEN 63: 74% to 46%; and PreserFlo: 75% to 47%. The length and the position of the tube in the AC had only a minimal (non-significant) effect on IOP (<0.1 mmHg). Conclusions This hydrodynamic/numerical model showed that implant diameter and bleb pressure are the two most pertinent determinants of hypotensive efficacy. In distinction, tube length and position in the AC do not significantly influence IOP.
    Keywords Medicine ; R ; Science ; Q
    Subject code 621
    Language English
    Publishing date 2020-01-01T00:00:00Z
    Publisher Public Library of Science (PLoS)
    Document type Article ; Online
    Database BASE - Bielefeld Academic Search Engine (life sciences selection)

    More links

    Kategorien

To top