  1. Article ; Online: A comparison of stiffness of six knee braces with application for posterolateral corner reconstructions.

    Hickie, Kirsten / Qiu, Yuelin / Baptiste, Jonelle Jn / Salipas, Andrew / Nathanail, Stephanie / Westover, Lindsey / Sommerfeldt, Mark

    Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine

    2023  Volume 237, Issue 8, Page(s) 985–990

    Abstract: Posterolateral corner knee injuries are clinically significant, and often require surgical reconstruction. The optimal knee brace following posterolateral corner reconstructions has not yet been determined via clinical nor biomechanical study. We sought ... ...

    Abstract Posterolateral corner knee injuries are clinically significant, and often require surgical reconstruction. The optimal knee brace following posterolateral corner reconstructions has not yet been determined via clinical nor biomechanical study. We sought to evaluate the stiffness of six types of knee braces to determine the ideal brace type for reducing varus forces, which may have clinical utility for posterolateral corner knee reconstruction rehabilitation. Six different groups of knee braces underwent mechanical testing: cruciate braces, cruciate braces with a valgus bend, medial unloaders, articulating sleeves, hinged braces, and tri-panel immobilizers. Each brace was fitted to the same fiberglass leg model and was secured to the testing apparatus. Force was applied under four-point bending to generate a varus moment about the artificial knee. The stiffness in Newtons per millimeter (N/mm) of each brace was calculated from the slope of the force-displacement curve. The cruciate brace with a valgus bend had the highest average stiffness at 192.61 N/mm (SD 28.53). The articulating sleeve was the least stiff with an average stiffness of 49.86 N/mm (SD 8.99). Stiffness of the cruciate brace was not statistically different compared to cruciate valgus (
    MeSH term(s) Humans ; Biomechanical Phenomena ; Braces ; Knee Injuries ; Knee Joint/surgery
    Language English
    Publishing date 2023-07-21
    Publishing country England
    Document type Comparative Study ; Journal Article
    ZDB-ID 1065942-0
    ISSN 2041-3033 ; 0046-2039 ; 0954-4119
    ISSN (online) 2041-3033
    ISSN 0046-2039 ; 0954-4119
    DOI 10.1177/09544119231188009
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  2. Article: Biomechanical Strength of All-Inside ACL Reconstruction Grafts Using Side-to-Side and Backup Fixation.

    Graf-Alexiou, Lucas / Karpyshyn, Jillian / Baptiste, Jonelle Jn / Hui, Catherine / Sommerfeldt, Mark / Westover, Lindsey

    Orthopaedic journal of sports medicine

    2021  Volume 9, Issue 5, Page(s) 23259671211006521

    Abstract: Background: The all-inside anterior cruciate ligament reconstruction (ACLR) procedure uses a single hamstring tendon folded twice and secured to itself to form a 4-stranded graft. There are several possible configurations for preparing the graft.: ... ...

    Abstract Background: The all-inside anterior cruciate ligament reconstruction (ACLR) procedure uses a single hamstring tendon folded twice and secured to itself to form a 4-stranded graft. There are several possible configurations for preparing the graft.
    Purpose: To investigate the biomechanical properties of a new graft preparation technique in comparison with 2 commonly used configurations.
    Study design: Controlled laboratory study.
    Methods: Five porcine flexor tendons were prepared into the test graft configuration: side-to-side fixation with a backup fixation at the button loop (graft M). The test configuration was compared with the results of a previous study that included grafts with simple interrupted sutures (graft A; n = 5) and end-to-end fixation (graft C; n = 5). All grafts were subjected to the same mechanical testing protocol to determine the mean failure load, stiffness, rate of elongation, and total elongation during both cyclic loading and pull to failure. Differences between groups were evaluated.
    Results: Graft A had a significantly lower failure load (637 ± 99 N) compared with graft M (883 ± 66 N;
    Conclusion: The new side-to-side configuration was not biomechanically superior to the end-to-end configuration; however, they were both stronger than unsecured fixation.
    Clinical relevance: As the all-inside ACLR is gaining popularity, this study provides surgeons with a new method of preparing grafts and evaluates the method with respect to currently used configurations.
    Language English
    Publishing date 2021-05-12
    Publishing country United States
    Document type Journal Article
    ZDB-ID 2706251-X
    ISSN 2325-9671
    ISSN 2325-9671
    DOI 10.1177/23259671211006521
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  3. Article: Biomechanical Comparison of Graft Preparation Techniques for All-Inside Anterior Cruciate Ligament Reconstruction.

    Bowes, Julia / Mohamed, Nada / Baptiste, Jonelle Jn / Westover, Lindsey / Hui, Catherine / Sommerfeldt, Mark

    Orthopaedic journal of sports medicine

    2020  Volume 8, Issue 7, Page(s) 2325967120938039

    Abstract: Background: All-inside anterior cruciate ligament reconstruction (ACLR) is an emerging technique used to treat ACL injuries. The all-inside technique uses a 4-stranded graft made from a single tendon that is looped on itself. The 4 strands of the graft ... ...

    Abstract Background: All-inside anterior cruciate ligament reconstruction (ACLR) is an emerging technique used to treat ACL injuries. The all-inside technique uses a 4-stranded graft made from a single tendon that is looped on itself. The 4 strands of the graft must be secured to each other to become a closed-loop structure. Various suture configurations exist to secure the graft to adjustable loop devices, and there is a lack of data to support one technique over another. In addition to the primary sutures used to fasten the graft together, accessory sutures can be tied over the button as secondary fixation.
    Purpose: To evaluate biomechanical properties of 4-stranded grafts prepared in 5 different configurations.
    Study design: Controlled laboratory study.
    Methods: Porcine flexor tendons (N = 25) were prepared in 5 different configurations (n = 5 tendons per group): simple-interrupted sutures (unsecured fixation), side-to-side fixation with and without secondary fixation, and end-to-end fixation with and without secondary fixation. The grafts were put through the same mechanical testing protocol (cyclic loading, pull to failure) to measure average load at graft failure, average displacement at failure, average stiffness, and average elongation rate. Differences between graft preparation techniques were investigated using 1-way analyses of variance (ANOVAs) with post hoc
    Results: Significant 1-way ANOVAs for each biomechanical property were found. Unsecured fixation was the weakest graft preparation with the lowest stiffness (167 ± 12 N/mm), lowest ultimate failure load (637 ± 99 N), and highest elongation rate (0.0033 ± 0.0007 mm/s). End-to-end fixation without secondary fixation showed the highest ultimate failure load (846 ± 26 N), highest stiffness (212 ± 10 N/mm), and lowest rate of elongation (0.0025 ± 0.0001 mm/s). End-to-end fixation, both with and without secondary fixation, as well as side-to-side fixation with secondary fixation showed significantly higher ultimate failure loads than grafts with unsecured fixation. End-to-end fixation performed better than side-to-side fixation; however, for most variables, the difference was not statistically significant. Secondary fixation did not provide significant improvement.
    Conclusion: The all-inside ACL graft with simple-interrupted sutures is biomechanically inferior to a graft that has its free ends secured to the adjustable tibial loop. Adding secondary fixation to the tibial button does not significantly change the biomechanical properties. Further clinical studies are required to determine whether these findings translate into differences in clinical outcome.
    Clinical relevance: All-inside ACLR is gaining popularity in hamstring ACL reconstructive techniques. These results provide surgeons with guidance on the best graft preparation method when using a single quadrupled hamstring tendon graft.
    Language English
    Publishing date 2020-07-24
    Publishing country United States
    Document type Journal Article
    ZDB-ID 2706251-X
    ISSN 2325-9671
    ISSN 2325-9671
    DOI 10.1177/2325967120938039