Abstract: Purpose: To assess the effect of the shooting angle variation on linear and planimetric measurements of the pink and white tissues on intraoral photographs.: Methods: From intraoral three-dimensional (3D) scans of the anterior region in 10 patients, ... ...
Abstract | Purpose: To assess the effect of the shooting angle variation on linear and planimetric measurements of the pink and white tissues on intraoral photographs. Methods: From intraoral three-dimensional (3D) scans of the anterior region in 10 patients, ninety-nine two-dimensional (2D) "scan pictures" each were generated with different shooting angles, each varying in 5° horizontal and vertical increments. Eleven intraoral photographs of each patient and tooth site were taken free-hand: one shot at baseline and 5 shots after 3 and 6 months at slightly varying shooting angles. Papilla height (PH) and area (PA) and tooth crown area (TCA) were estimated on all photographs; the "best-match-to-baseline" photograph from those taken at 3 and 6 months was chosen by 6 evaluators. Results: Within the first 10° of deviation from the baseline shooting angle, measurements on the 2D "scan pictures" distorted ≤0.5 mm for PH and ≤10% for PA and TCA. Compared to baseline, only 6 out of 100 photographs presented ≥0.5 mm difference in PH, none of the TCA measurements showed distortion ≥10%, and only in 4 instances a ≥10% distortion of the PA was observed. Poor to moderate inter- and intra-rater agreement in choosing the "best-match-to-baseline" photograph was found, but photographs with clinically relevant changes were only seldomly chosen. Conclusions: Deviations in the shooting angle ≤10° from the baseline shot cause clinically negligible distortions in linear and planimetric measurements. Highly comparable intraoral photographs of the anterior maxillary teeth can be captured "free-hand" in slightly varying perspective, and then selecting the "best-match-to-baseline". |
---|---|
MeSH term(s) | Humans ; Photography, Dental ; Reproducibility of Results ; Tooth |
Language | English |
Publishing date | 2019-04-30 |
Publishing country | Japan |
Document type | Journal Article |
ZDB-ID | 2470657-7 |
ISSN | 2212-4632 ; 1883-1958 |
ISSN (online) | 2212-4632 |
ISSN | 1883-1958 |
DOI | 10.1016/j.jpor.2019.04.001 |
Database | MEDical Literature Analysis and Retrieval System OnLINE |
Full text online
More links
Kategorien
In stock of ZB MED Cologne/Königswinter
Zs.A 3907: Show issues | Location: Je nach Verfügbarkeit (siehe Angabe bei Bestand) bis Jg. 1994: Bestellungen von Artikeln über das Online-Bestellformular Jg. 1995 - 2021: Lesesall (2.OG) ab Jg. 2022: Lesesaal (EG) |
Order via subito
This service is chargeable due to the Delivery terms set by subito. Orders including an article and supplementary material will be classified as separate orders. In these cases, fees will be demanded for each order.