  1. Article: Is It Possible to Replace Conventional Radiography (CR) with a Dose Neutral Computed Tomography (CT) of the Cervical Spine in Emergency Radiology-An Experimental Cadaver Study.

    Deak, Zsuzsanna / Brummund, Lindis / Kirchhoff, Sonja / Körner, Markus / Geyer, Lucas / Mück, Fabian / Scaglione, Mariano / Reiser, Maximilian / Linsenmaier, Ulrich

    Diagnostics (Basel, Switzerland)

    2022  Volume 12, Issue 8

    Abstract: The purpose of this experimental study on recently deceased human cadavers was to investigate whether (I) the radiation exposure of the cervical spine CT can be reduced comparable to a dose level of conventional radiography (CR); and (II) whether and ... ...

    Abstract The purpose of this experimental study on recently deceased human cadavers was to investigate whether (I) the radiation exposure of the cervical spine CT can be reduced comparable to a dose level of conventional radiography (CR); and (II) whether and which human body parameters can be predictive for higher dose reduction potential (in this context).
    Materials and methods: Seventy serial CT scans of the cervical spine of 10 human cadavers undergoing postmortem virtual autopsy were taken using stepwise decreasing upper limits of the tube current (300 mAs, 150 mAs, 110 mAs, 80 mAs, 60 mAs, 40 mAs, and 20 mAs) at 120 kVp. An additional scan acquired at a fixed tube current of 300 mAs served as a reference. Images were reconstructed with filtered back projection and the upper (C1-4) and lower (C4-7) cervical spine were evaluated by three blinded readers for image quality, regarding diagnostic value and resolution of anatomical structures according to a semiquantitative three-point-scale. Dose values and individual physical parameters were recorded. The relationship of diagnostic IQ, dose reduction level, and patients' physical parameters were investigated. The high-contrast resolution of the applied CT protocols was tested in an additional phantom study.
    Results: The IQ of the upper cervical spine was diagnostic at 1.69 ± 0.58 mGy (CTDI) corresponding to 0.20 ± 0.07 mSv (effective dose) in all cadavers. IQ of the lower cervical spine was diagnostic at 4.77 ± 1.86 mGy corresponding to 0.560 ± 0.21 mSv (effective dose) in seven cadavers and at 2.60 ± 0.93 mGy corresponding to 0.31 ± 0.11 mSv in four cadavers. Significant correlation was detected for BMI (0.8366;
    Conclusions: Conventional radiography can be replaced with a nearly dose-neutral CT scan of the cervical spine.
    Language English
    Publishing date 2022-08-02
    Publishing country Switzerland
    Document type Journal Article
    ZDB-ID 2662336-5
    ISSN 2075-4418
    ISSN 2075-4418
    DOI 10.3390/diagnostics12081872
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  2. Book ; Online ; Thesis: Untersuchungen zum dosisneutralen Ersatz der Projektionsradiographie (CR) in der Bildgebung der HWS durch Niedrigdosis Multidetektor-Computertomographie (MDCT)

    Brummund, Lindis [Verfasser] / Linsenmaier, Ulrich [Akademischer Betreuer]

    eine experimentelle Studie

    2017  

    Author's details Lindis Brummund ; Betreuer: Ulrich Linsenmaier
    Keywords Medizin, Gesundheit ; Medicine, Health
    Subject code sg610
    Language German
    Publisher Universitätsbibliothek der Ludwig-Maximilians-Universität
    Publishing place München
    Document type Book ; Online ; Thesis
    Database Digital theses on the web

    More links

    Kategorien

To top