LIVIVO - The Search Portal for Life Sciences

zur deutschen Oberfläche wechseln
Advanced search

Search results

Result 1 - 2 of total 2

Search options

  1. Article ; Online: Does plate position influence the outcome in midshaft clavicular fractures? A multicenter analysis.

    Buenter, Isabelle Ruth / Kremo, Valerie / Beeres, Frank Johannes Paulus / van Veelen, Nicole Maria / Galliker, Beat / Link, Bjoern-Christian / Babst, Reto / Pape, Hans-Christoph / van de Wall, Bryan Joost Marinus

    European journal of trauma and emergency surgery : official publication of the European Trauma Society

    2024  

    Abstract: Purpose: To date, it remains unclear whether superior or anterior plating is the best option for treating midshaft clavicular fractures. The aim of this study was to compare both techniques with regard to the incidence of implant removal due to implant ... ...

    Abstract Purpose: To date, it remains unclear whether superior or anterior plating is the best option for treating midshaft clavicular fractures. The aim of this study was to compare both techniques with regard to the incidence of implant removal due to implant irritation, risk of complications, time to union, and function.
    Methods: In this retrospective cohort study, all midshaft clavicular fractures treated operatively between 2017 and 2020 in two hospitals in Switzerland were analyzed. The participating hospitals differed with regard to their standard practice; one offered superior plating only, while the other predominantly employed an anterior plate. The primary outcome was the incidence of implant removal for irritation. Secondary outcomes were time to union, complications, re-interventions, and range of motion during the follow-up period of at least 6 months.
    Results: In total, 168 patients were included in the study of which 81 (48%) received anterior plating and 87 (52%) superior plating. The overall mean age was 45 years (SD 16). There was no significant difference between anterior and superior plating with regard to implant removal (58.5% versus 57.1%, p = 0.887), infection (5.7% versus 1.8%, p = 0.071), and time to union (median 48 weeks versus 52 weeks, p = 0.643). Data on range of motion were available in 71 patients. There was no significant difference in anteflexion (median 180 degrees anterior versus 180 degrees superior) and abduction (median 180 degrees anterior versus 180 degrees superior) between the two groups.
    Conclusion: This retrospective cohort study did not find sufficient evidence to recommend one implant position over the other for midshaft clavicular fractures with regard to removal due to irritation. Time to union was similar and Infections were equally rare in both groups. Notably, a considerable number of patients in both groups had their implants removed due to irritation. Larger prospective studies are needed to determine how much plate position contributes to the occurrence of irritation and whether other patient or implant-related factors might play a role. Until this is clarified, implant position should be based on surgeons preference and experience.
    Language English
    Publishing date 2024-01-17
    Publishing country Germany
    Document type Journal Article
    ZDB-ID 2275480-5
    ISSN 1863-9941 ; 1863-9933
    ISSN (online) 1863-9941
    ISSN 1863-9933
    DOI 10.1007/s00068-023-02400-y
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  2. Article ; Online: The value of fibular fixation in patients with stabilized distal tibia fractures.

    van Veelen, Nicole Maria / van de Wall, Bryan Joost Marinus / Bleeker, Nils Jan / Buenter, Isabelle Ruth / Link, Björn-Christian / Babst, Reto / Knobe, Matthias / Beeres, Frank Joseph Paulus

    European journal of trauma and emergency surgery : official publication of the European Trauma Society

    2022  Volume 48, Issue 4, Page(s) 3257–3263

    Abstract: Purpose: There is currently no consensus regarding the need for fixation of concomitant fibula fractures in patients with surgically treated distal tibia fracture. Although studies have shown it to be beneficial for fractures involving the syndesmosis, ... ...

    Abstract Purpose: There is currently no consensus regarding the need for fixation of concomitant fibula fractures in patients with surgically treated distal tibia fracture. Although studies have shown it to be beneficial for fractures involving the syndesmosis, it remains unclear for suprasyndesmotic fractures. This study evaluates what effect the fixation of such suprasyndesmotic fibula fractures had on patients who underwent fixation of distal tibia fractures.
    Methods: This retrospective cohort study included all consecutive adult patients who received surgical treatment for an extra-articular or simple intraarticular distal tibia fracture between 2012 and 2020 and had a concomitant fibula fracture proximal to the syndesmosis. Two groups were formed depending on whether the fibula was stabilized. The need for revision surgery, the occurrence of complications, fracture healing, rotational and angular malalignment were evaluated for both groups.
    Results: This study included 120 patients, of which 40 (33.3%) had operative treatment of the fibula fracture. Of those with stabilized fibula fractures, 28 (70%) were treated with a plate and 12 (30%) with a titanium elastic nail. The group of patients with surgically treated fibula fractures had significantly more angular malalignments (10% vs 1.2%, p = 0.042), while there was no difference regarding rotational malalignment or fracture healing. Further, infections of the fibular surgical site occurred in 15% of surgically treated patients leading to significantly more revision surgeries in this group (40% vs 20%, p = 0.03). All infections occurred when a plate was used.
    Conclusion: This study was unable to show any benefit from stabilizing concomitant, suprasyndesmotic fibula fractures in surgically treated distal tibia fractures. On the contrary, infection, revision surgery and angular malalignment were more frequent when the fibula was fixed. Therefore, such concomitant fibula fractures should not routinely be fixed and if stabilization is deemed necessary, the implant should be chosen carefully.
    MeSH term(s) Adult ; Ankle Fractures ; Fibula/surgery ; Fracture Fixation, Internal ; Fracture Fixation, Intramedullary ; Humans ; Retrospective Studies ; Tibia ; Tibial Fractures/surgery ; Treatment Outcome
    Language English
    Publishing date 2022-02-04
    Publishing country Germany
    Document type Journal Article
    ZDB-ID 2275480-5
    ISSN 1863-9941 ; 1863-9933
    ISSN (online) 1863-9941
    ISSN 1863-9933
    DOI 10.1007/s00068-022-01888-0
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

To top