LIVIVO - The Search Portal for Life Sciences

zur deutschen Oberfläche wechseln
Advanced search

Search results

Result 1 - 10 of total 33

Search options

  1. Article ; Online: Role of fibular autograft in ankle arthrodesis fixed using cannulated screws: a proportional meta-analysis and systematic review.

    Bernasconi, Alessio / Izzo, Antonio / D'Agostino, Martina / Mariconda, Massimo / Coviello, Antonio

    Scientific reports

    2023  Volume 13, Issue 1, Page(s) 18614

    Abstract: Ankle arthrodesis is commonly performed to treat end-stage ankle osteoarthritis. The aim of this study was to determine whether the use of fibular autograft might increase the fusion rate and decrease the complication rate in ankle arthrodesis (AA) fixed ...

    Abstract Ankle arthrodesis is commonly performed to treat end-stage ankle osteoarthritis. The aim of this study was to determine whether the use of fibular autograft might increase the fusion rate and decrease the complication rate in ankle arthrodesis (AA) fixed using cannulated screws. To perform this PRISMA-compliant proportional meta-analysis, multiple databases were searched for studies in which patients undergone AA (using exclusively cannulated screws and augmented with fibular bone graft) were followed. The characteristics of the cohort, the study design, surgical details, the nonunion and complication rate at the longest follow-up were extracted and recorded. The modified Coleman Methodology Score (mCMS) was applied to appraise the quality of studies. Two groups were built: arthrodeses fixed with screws combined with cancellous autograft (G1) and arthrodeses fixed with screws combined with cancellous autograft and augmented with a lateral fibular onlay (G2). A third group (arthrodeses fixed with screws and no graft, G3) was extracted from previous literature for a further comparison. Overall, we included 306 ankles (296 patients) from ten series (ten studies). In G1 and G2 there were 118 ankles (111 patients) and 188 ankles (185 patients), respectively. In patients where cancellous autograft was used, a further augmentation with a fibular lateral strut autograft did not change significantly the nonunion (4% [95% CI 1-9] in G1 vs. 2% [95% CI 0-5) in G2, p = 0.99) nor the complication rate (18% [95% CI 0-36] in G1 vs. 13% [95% CI 6-21) in G2, p = 0.71). Upon comparison with 667 ankles (659 patients, G3) in which arthrodeses had been performed without grafting, the nonunion and complication rates did not differ significantly either (pooled estimates: 3% [95% CI 1-3) in G1 + G2 vs. 3% [95% CI 2-4] in G3, p = 0.73 for nonunion; 15% [8-23] in G1 + G2 vs. 13% [95% CI 9-17] in G3, p = 0.93 for complications). In ankle arthrodesis fixed with cannulated screws combined with cancellous autograft at the fusion site, a construct augmentation with a distal fibular onlay strut graft positioned laterally at the ankle joint does not reduce the risk of nonunion or complication. In general, the use of bone graft does not influence significantly the nonunion nor the complication rate as compared to non-grafted screw-fixed ankle arthrodeses.Kindly check and confirm the corresponding author mail id is correctly identified.It's all correct.
    MeSH term(s) Humans ; Ankle ; Autografts ; Ankle Joint/surgery ; Fibula ; Arthrodesis/adverse effects ; Arthrodesis/methods ; Retrospective Studies
    Language English
    Publishing date 2023-10-30
    Publishing country England
    Document type Meta-Analysis ; Systematic Review ; Journal Article
    ZDB-ID 2615211-3
    ISSN 2045-2322 ; 2045-2322
    ISSN (online) 2045-2322
    ISSN 2045-2322
    DOI 10.1038/s41598-023-46034-x
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  2. Article ; Online: Does the Number of Screws Influence the Union Rate in Ankle Arthrodesis? A Meta-analysis and Systematic Review.

    Izzo, Antonio / Sgadari, Arianna / Coviello, Antonio / Smeraglia, Francesco / Balato, Giovanni / Mariconda, Massimo / Bernasconi, Alessio

    Foot & ankle specialist

    2023  , Page(s) 19386400231171508

    Abstract: Objective: The purpose of this study was to determine whether the number of cannulated screws used during ankle arthrodesis (AA) might influence the union and complication rate.: Methods: In this Preferred Reporting Items for Systematic Reviews and ... ...

    Abstract Objective: The purpose of this study was to determine whether the number of cannulated screws used during ankle arthrodesis (AA) might influence the union and complication rate.
    Methods: In this Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA)-compliant PROSPERO-registered systematic review, multiple databases were searched including studies in which patients undergone AA using cannulated screws as exclusive fixation method were followed. Data were harvested regarding the cohort, the study design, the surgical technique, the nonunion, and complication rate at the longest follow-up. Risk of bias was assessed using the modified Coleman Methodology Score (mCMS). Two groups were built (arthrodeses fixed with 2 screws [group 1, G1] vs arthrodeses fixed with 3 screws [group 2 G2]) and compared.
    Results: Fifteen series of patients from 15 studies (667 ankles) were selected (G1 = 458 ankles and G2 = 209). The pooled proportion estimate revealed a similar nonunion rate in the 2-screw group as compared with the 3-screw group (4% vs 3%; P = .68). The pooled proportion of complications was higher in G1 (19%) than in G2 (8%), but it was not significantly different either (P = .45). After exclusion of "symptomatic hardware and screw removal," the difference was still not significant (P = .28) although it resulted lower in G1 than in G2 (4% vs 8%, respectively).
    Conclusions: Using 3 cannulated screws during AA as compared with a 2-screw construct does not significantly reduce the risk of nonunion nor the risk of complications.
    Level of evidence: Level IV, Systematic review of level IV.
    Language English
    Publishing date 2023-05-11
    Publishing country United States
    Document type Journal Article ; Review
    ZDB-ID 2488579-4
    ISSN 1938-7636 ; 1938-6400
    ISSN (online) 1938-7636
    ISSN 1938-6400
    DOI 10.1177/19386400231171508
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  3. Article: Analysis of the 50 Most Cited Articles on Achilles Tendon Injury.

    Sgadari, Arianna / Izzo, Antonio / Smeraglia, Francesco / Coviello, Antonio / Patel, Shelain / Mariconda, Massimo / Bernasconi, Alessio

    Orthopaedic journal of sports medicine

    2023  Volume 11, Issue 5, Page(s) 23259671231170846

    Abstract: Background: Achilles tendon injuries represent one of the most common reasons for referral to orthopaedic surgeons.: Purpose: To outline the characteristics, examine trends in publication, and evaluate the correlation between citations and study ... ...

    Abstract Background: Achilles tendon injuries represent one of the most common reasons for referral to orthopaedic surgeons.
    Purpose: To outline the characteristics, examine trends in publication, and evaluate the correlation between citations and study quality of the 50 most cited articles on Achilles tendon injury.
    Study design: Cross-sectional study.
    Methods: After searching the Web of Science for articles published in orthopaedic journals, we identified the 50 most cited articles on Achilles tendon injury and abstracted their characteristics. Risk of bias was assessed using the modified Coleman Methodology Score (mCMS). Multiple bivariate analyses (Pearson or Spearman correlation coefficient) were used to evaluate the association among number of citations, citation rate (citations/year), 2020 journal impact factor (JIF), year of publication, level of evidence (LoE), study type (tendon rupture or chronic tendinopathy), sample size, and mCMS.
    Results: The top 50 articles were cited 12,194 times. Each article had a mean ± SD 244 ± 88.8 citations (range, 157-657) and a citation rate of 12.6 ± 5.4 per year (range, 3-28). A total of 35 studies (70%) were published between 2000 and 2010. The citation rate of the 16 most recent studies was almost double that of the 16 oldest studies (17.5 vs 9.9;
    Conclusion: The mean LoE and the citation rate of the most cited articles on Achilles tendon injury both significantly increased over time. Although the JIF was positively correlated with study quality, almost half of the studies had poor-quality methodology.
    Language English
    Publishing date 2023-05-19
    Publishing country United States
    Document type Journal Article
    ZDB-ID 2706251-X
    ISSN 2325-9671
    ISSN 2325-9671
    DOI 10.1177/23259671231170846
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  4. Article ; Online: Irritation from metalwork after ankle arthrodesis fixed using screws: a proportional meta-analysis and systematic review.

    Izzo, Antonio / Sgadari, Arianna / Santagata, Salvatore / Coviello, Antonio / Cozzolino, Andrea / Mariconda, Massimo / Bernasconi, Alessio

    Archives of orthopaedic and trauma surgery

    2023  Volume 143, Issue 8, Page(s) 4861–4870

    Abstract: Objective: Ankle arthrodesis (AA) is often fixed using cannulated screws. The irritation from metalwork is a relatively common complication, but there is no consensus regarding the need to remove the screws on a systematic basis. The aim of this study ... ...

    Abstract Objective: Ankle arthrodesis (AA) is often fixed using cannulated screws. The irritation from metalwork is a relatively common complication, but there is no consensus regarding the need to remove the screws on a systematic basis. The aim of this study was to determine (1) the proportion of screws removed after AA and (2) whether predictors of screw removal could be identified.
    Methods: This PRISMA-compliant systematic review was part of a larger previous protocol registered on the PROSPERO platform. Multiple databases were searched including studies in which patients undergone AA using screws as exclusive fixation method were followed. Data were harvested regarding the cohort, the study design, the surgical technique, the nonunion and complication rate at the longest follow-up. Risk of bias was assessed using the modified Coleman Methodology Score (mCMS).
    Results: Forty-four series of patients from thirty-eight studies (1990 ankles, 1934 patients) were selected. The average follow-up was 40.8 months (range 12-110). In all studies, hardware was removed due to symptoms reported by patients and related to the screws. The pooled proportion of removal of metalwork was 3% (95% CI 2-4). The pooled proportion of fusion was 96% (95%CI 95-98), while the pooled proportion of complications and reoperations (excluding the removal of metalwork) stood at 15% (95% CI 11-18) and 3% (95% CI 2-4), respectively. The mean mCMS (50.8 ± 8.1, range 35-66) revealed only an overall fair quality of studies. The univariate analysis and the multivariate model showed that the year of publication (R = - 0.004; p = 0.01) and the number of screws (R = 0.08; p = 0.01) were associated with the screw removal rate. Specifically, we found that over time the removal rate decreased by 0.4% per year and that the use of three screws instead of two reduced the risk of removal of metalwork by 8%.
    Conclusions: In this review, removal of metalwork after ankle arthrodesis using cannulated screws was needed in 3% of cases at an average follow-up of 40.8 months. It was indicated only in case of symptoms related to soft tissue irritation from screws. The use of three screws was paradoxically related to a reduced risk of removal of screws as compared to two-screw constructs.
    Level of evidence: Level IV, systematic review of Level IV.
    MeSH term(s) Humans ; Ankle ; Ankle Joint/surgery ; Bone Screws/adverse effects ; Arthrodesis/adverse effects ; Arthrodesis/methods ; Retrospective Studies
    Language English
    Publishing date 2023-02-16
    Publishing country Germany
    Document type Systematic Review ; Meta-Analysis ; Journal Article ; Review
    ZDB-ID 80407-1
    ISSN 1434-3916 ; 0003-9330 ; 0344-8444
    ISSN (online) 1434-3916
    ISSN 0003-9330 ; 0344-8444
    DOI 10.1007/s00402-023-04813-1
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  5. Article: The Effects of the Pericapsular Nerve Group Block on Postoperative Pain in Patients with Hip Fracture: A Multicenter Study.

    Iacovazzo, Carmine / Sara, Rosario / Buonanno, Pasquale / Vargas, Maria / Coviello, Antonio / Punzo, Roberta / Maffei, Vincenzo / Marra, Annachiara

    Diagnostics (Basel, Switzerland)

    2024  Volume 14, Issue 8

    Abstract: Background: An adequate early mobilization followed by an effective and pain-free rehabilitation are critical for clinical and functional recovery after hip and proximal femur fracture. A multimodal approach is always recommended so as to reduce the ... ...

    Abstract Background: An adequate early mobilization followed by an effective and pain-free rehabilitation are critical for clinical and functional recovery after hip and proximal femur fracture. A multimodal approach is always recommended so as to reduce the administered dose of analgesics, drug interactions, and possible side effects. Peripheral nerve blocks should always be considered in addition to spinal or general anesthesia to prolong postoperative analgesia. The pericapsular nerve group (PENG) block appears to be a less invasive and more effective analgesia technique compared to other methods.
    Methods: We conducted multicenter retrospective clinical research, including 98 patients with proximal femur fracture undergoing osteosynthesis surgery within 48 h of occurrence of the fracture. Thirty minutes before performing spinal anesthesia, 49 patients underwent a femoral nerve (FN) block plus a lateral femoral cutaneous nerve (LCFN) block, and the other 49 patients received a PENG block. A non-parametric Wilcoxon-Mann-Whitney (α = 0.05) test was performed to evaluate the difference in resting and dynamic numerical rating scale (NRS) at 30 min, 6 h, 12 h, and 24 h.
    Results: the PENG block administration was more effective in reducing pain intensity compared to the FN block in association with the LFCN block, as seen in the resting and dynamic NRS at thirty minutes and 12 h follow-up.
    Conclusion: the PENG block was more effective in reducing pain intensity than the femoral nerve block associated with the lateral femoral cutaneous nerve block in patients with proximal femur fracture undergoing to osteosynthesis.
    Language English
    Publishing date 2024-04-17
    Publishing country Switzerland
    Document type Journal Article
    ZDB-ID 2662336-5
    ISSN 2075-4418
    ISSN 2075-4418
    DOI 10.3390/diagnostics14080827
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  6. Article: Erector spinae plane block in laparoscopic nephrectomy as a cause of involuntary hemodynamic instability: A case report.

    Coviello, Antonio / Golino, Ludovica / Maresca, Alfredo / Vargas, Maria / Servillo, Giuseppe

    Clinical case reports

    2021  Volume 9, Issue 5, Page(s) e04026

    Abstract: The Ultrasound-guided erector spinae plane block (US-ESPB), used as an anesthesiological block for opioid-sparing approach and for postoperative analgesia, could represent an involuntary cause of hemodynamic instability. This hemodynamic instability is ... ...

    Abstract The Ultrasound-guided erector spinae plane block (US-ESPB), used as an anesthesiological block for opioid-sparing approach and for postoperative analgesia, could represent an involuntary cause of hemodynamic instability. This hemodynamic instability is accentuated by a greater diffusion of local anesthetic in the epidural space.
    Language English
    Publishing date 2021-03-31
    Publishing country England
    Document type Case Reports
    ZDB-ID 2740234-4
    ISSN 2050-0904
    ISSN 2050-0904
    DOI 10.1002/ccr3.4026
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  7. Article ; Online: Opioid-free anesthesia-dexmedetomidine as adjuvant in erector spinae plane block: a case series.

    Coviello, Antonio / Esposito, Danilo / Galletta, Roberta / Maresca, Alfredo / Servillo, Giuseppe

    Journal of medical case reports

    2021  Volume 15, Issue 1, Page(s) 276

    Abstract: Background: Laparoscopic pain is related to the stretching of the peritoneum and peritoneal irritation caused by insufflation of the parietal peritoneum with carbon dioxide. In 2017, erector spinae plane block (ESPB) was described for management of ... ...

    Abstract Background: Laparoscopic pain is related to the stretching of the peritoneum and peritoneal irritation caused by insufflation of the parietal peritoneum with carbon dioxide. In 2017, erector spinae plane block (ESPB) was described for management of postoperative pain following open and laparoscopic abdominal surgery. The use of multimodal anesthesia reduces both intraoperative and postoperative opioid use and improves analgesia. The addition of dexmedetomidine to the anesthetic mixture significantly prolongs analgesia, without clinically significant side effects.
    Case presentation: We describe a series of three Caucasian women cases that illustrate the efficacy of bilateral ESPB performed at the level of the T7 transverse process to provide intraoperative and postoperative analgesia for laparoscopic gynecological surgery.
    Conclusion: Further investigation is recommended to establish the potential for ESPB with dexmedetomidine as adjuvant as an opioid-free anesthetic modality in laparoscopic gynecological surgery.
    MeSH term(s) Analgesics, Opioid ; Dexmedetomidine ; Female ; Humans ; Nerve Block ; Pain, Postoperative/drug therapy ; Paraspinal Muscles/diagnostic imaging
    Chemical Substances Analgesics, Opioid ; Dexmedetomidine (67VB76HONO)
    Language English
    Publishing date 2021-05-29
    Publishing country England
    Document type Journal Article ; Case Reports
    ZDB-ID 2269805-X
    ISSN 1752-1947 ; 1752-1947
    ISSN (online) 1752-1947
    ISSN 1752-1947
    DOI 10.1186/s13256-021-02868-5
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  8. Article: Anesthetic management in a patient with Arnold-Chiari malformation type 1,5: A case report.

    Coviello, Antonio / Golino, Ludovica / Posillipo, Concetta / Marra, Annachiara / Tognù, Andrea / Servillo, Giuseppe

    Clinical case reports

    2022  Volume 10, Issue 2, Page(s) e05194

    Abstract: A 42-year-old male patient with Arnold-Chiari malformation type 1,5 (ACM-1,5) came to implant a hip prosthesis. He underwent a previous general anesthesia, with difficult airway management and complication in awakening. In this second surgery, an ... ...

    Abstract A 42-year-old male patient with Arnold-Chiari malformation type 1,5 (ACM-1,5) came to implant a hip prosthesis. He underwent a previous general anesthesia, with difficult airway management and complication in awakening. In this second surgery, an extradural approach was preferred to keep intracranial pressure and hemodynamics stable.
    Language English
    Publishing date 2022-02-04
    Publishing country England
    Document type Case Reports
    ZDB-ID 2740234-4
    ISSN 2050-0904
    ISSN 2050-0904
    DOI 10.1002/ccr3.5194
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  9. Article ; Online: Tetra-block: ultrasound femoral, lateral femoral-cutaneous, obturator, and sciatic nerve blocks in lower limb anesthesia: a case series.

    Coviello, Antonio / Iacovazzo, Carmine / Cirillo, Dario / Diglio, Pasquale / Bernasconi, Alessio / Cozzolino, Andrea / Izzo, Antonio / Marra, Annachiara / Servillo, Giuseppe / Vargas, Maria

    Journal of medical case reports

    2023  Volume 17, Issue 1, Page(s) 270

    Abstract: Background: The gold standard anesthesiologic procedure for urgent femur fracture surgery is Spinal Anesthesia. It is not always feasible because of patients' severe comorbidities and difficulties in optimizing drug therapy in the appropriate time frame ...

    Abstract Background: The gold standard anesthesiologic procedure for urgent femur fracture surgery is Spinal Anesthesia. It is not always feasible because of patients' severe comorbidities and difficulties in optimizing drug therapy in the appropriate time frame such as discontinuation of anticoagulant drugs. The use of four peripheral nerve blocks (tetra-block) can be a winning weapon when all seems lost.
    Case presentation: We present, in this case series, three Caucasian adult femur fractures (an 83-year-old woman, a 73-year-old man, and a 68-year-old woman) with different and major comorbidities (cardiac or circulatory disorders on anticoagulants therapy that were not discontinued on time; breast cancer and others) underwent the same anesthesiologic approach in the urgent setting. Ultrasound peripheral nerve blocks, that is femoral, lateral femoral cutaneous, obturator, and sciatic with parasacral approach were successfully performed in all patients who underwent intramedullary nailing for intertrochanteric fracture. We evaluated the adequacy of the anesthesia plane, postoperative pain control with the VAS scale, and the incidence of postoperative side effects.
    Conclusions: Four peripheral nerve blocks (Tetra-block) can be alternative anesthesiologic management in urgent settings, in patients where drug therapy cannot be optimized, as in antiplatelet and anticoagulant therapy.
    MeSH term(s) Adult ; Male ; Female ; Humans ; Aged, 80 and over ; Aged ; Femur ; Lower Extremity ; Anesthesia, Spinal ; Femoral Fractures ; Anticoagulants ; Sciatic Nerve/diagnostic imaging
    Chemical Substances Anticoagulants
    Language English
    Publishing date 2023-07-01
    Publishing country England
    Document type Case Reports ; Journal Article
    ZDB-ID 2269805-X
    ISSN 1752-1947 ; 1752-1947
    ISSN (online) 1752-1947
    ISSN 1752-1947
    DOI 10.1186/s13256-023-04017-6
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  10. Article: Impact of Ultrasound-Assisted Method on Success Rate of Spinal Anesthesia Performed by Novice Trainees: A Retrospective Comparative Study.

    Coviello, Antonio / Iacovazzo, Carmine / Piccione, Ilaria / Posillipo, Concetta / Barone, Maria Silvia / Ianniello, Marilena / de Siena, Andrea Uriel / Cirillo, Dario / Vargas, Maria

    Journal of personalized medicine

    2023  Volume 13, Issue 10

    Abstract: In current practice, single-shot spinal anesthesia has traditionally been performed using the conventional surface-anatomic-Landmark-Guided technique. This "blind" technique has significant critical issues such as a high risk of complications due to the ... ...

    Abstract In current practice, single-shot spinal anesthesia has traditionally been performed using the conventional surface-anatomic-Landmark-Guided technique. This "blind" technique has significant critical issues such as a high risk of complications due to the numerous attempts at spinal needle placement and the negative impact on the learning curve of the trainees. Ultrasound-Assisted spinal anesthesia could reduce these critical issues and allow trainees to perform the procedure more easily and with fewer complications for the patient. We performed a before-and-after monocentric retrospective comparative study at the University of Naples "Federico II" (Naples, Italy). Inclusion criteria were as follows: patients aged 18 years or older; ASA physical status between I and IV; and elective orthopedic surgery under single-shot spinal anesthesia performed by supervised trainees between January 2022 and December 2022. In the selected cohort, 88 patients were included in group A (Landmark-Guided spinal anesthesia) and 91 in group B (Ultrasound-Assisted spinal anesthesia). The number of attempts by trainees (
    Language English
    Publishing date 2023-10-21
    Publishing country Switzerland
    Document type Journal Article
    ZDB-ID 2662248-8
    ISSN 2075-4426
    ISSN 2075-4426
    DOI 10.3390/jpm13101515
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

To top