LIVIVO - Das Suchportal für Lebenswissenschaften

switch to English language
Erweiterte Suche

Ihre letzten Suchen

  1. AU="Daniele Garcovich"
  2. AU="Nachiappan, Nachal"
  3. AU="Aguilar, Gislani Mateus Oliveira"
  4. AU=Roknic Nikola
  5. AU="Bommireddy, Vikram Simha"
  6. AU="Healy, Jeremiah C."
  7. AU="Noelle Enright"
  8. AU="Yue Leon Guo"
  9. AU="Selph, Shelley S"
  10. AU="Eric A Weingarten"
  11. AU="Agus, Marcello"
  12. AU="Pan, Fupeng"
  13. AU="Picus, Roberto"
  14. AU="Manai, Marwa"
  15. AU=Gimenez-Mascarell Paula
  16. AU="Kazem Asadollahi"
  17. AU="Tomaino, Elisabetta"
  18. AU="Bao, Xingce"
  19. AU="Santos, Ohanna Thays de Medeiros"
  20. AU="Bou-Cabo, M."
  21. AU="Hwang, Young"
  22. AU="Jia, Lingyue"
  23. AU="Qiao, Haoran"
  24. AU=Ning Li
  25. AU="Djillali, Salih"

Suchergebnis

Treffer 1 - 10 von insgesamt 16

Suchoptionen

  1. Artikel ; Online: The Online Attention to Research in Legal Medicine

    Daniele Garcovich / Angel Zhou Wu / Milagros Adobes Martin

    Forensic Sciences, Vol 3, Iss 33, Pp 478-

    An Altmetric Study on the Most Discussed Articles on the Web

    2023  Band 490

    Abstract: Background: Online attention is a relevant research feature that can be related to its societal impact. Online attention in the field of legal medicine was explored as well as the relation between citation count and the Altmetric Attention Score (AAS). ... ...

    Abstract Background: Online attention is a relevant research feature that can be related to its societal impact. Online attention in the field of legal medicine was explored as well as the relation between citation count and the Altmetric Attention Score (AAS). Methods: A search was performed, through the free Dimensions app, during September 2020, on the journals related to legal medicine listed in the 2019 edition of the Journal Citation Reports (JCR). The 200 published items with the highest AAS were retrieved and screened for bibliometric data. Articles with related citations were gathered from Web of Science (WOS), Scopus, and Dimensions. Results: Seventy-five percent of the articles were published by five of the selected journals. Twitter and news outlets were the most prevalent Altmetric resources. Additionally, 73.5% of the articles were published between 2013 and 2020. The most frequent topics were the ones related to toxicology and pharmacology, followed by criminalistics and law and bioethics. A poor correlation was found between the citations in WOS, Dimensions, and Scopus and the AAS. Conclusions: The online attention on legal medicine-related topics can be considered high on social media. The high number of news outlets is a distinctive feature of the most discussed articles in legal medicine. In this field of medicine, citation-based metrics combined with Altmetric can allow a broader evaluation of research findings but it should be underlined that, when measuring very different aspects of a published item, the scores in classic citation databases and Altmetric do not have a direct relation.
    Schlagwörter bibliometrics ; citation analysis ; legal medicine ; Altmetric ; Scopus ; Dimensions ; Social pathology. Social and public welfare. Criminology ; HV1-9960 ; Analytical chemistry ; QD71-142
    Thema/Rubrik (Code) 001
    Sprache Englisch
    Erscheinungsdatum 2023-08-01T00:00:00Z
    Verlag MDPI AG
    Dokumenttyp Artikel ; Online
    Datenquelle BASE - Bielefeld Academic Search Engine (Lebenswissenschaftliche Auswahl)

    Zusatzmaterialien

    Kategorien

  2. Artikel ; Online: Location and Gender Differences in Osteonecrosis of the Jaws in Patients Treated with Antiresorptive and Antineoplastic Drugs Undergoing Dentoalveolar Surgical, Systematic Review with Meta-Analysis and Trial Sequential Analysis

    Mario Dioguardi / Francesca Spirito / Mario Alovisi / Riccardo Aiuto / Daniele Garcovich / Vito Crincoli / Andrea Ballini / Giorgia Apollonia Caloro / Lorenzo Lo Muzio

    Journal of Clinical Medicine, Vol 12, Iss 3299, p

    2023  Band 3299

    Abstract: In the treatment and prevention of osteoporosis and more generally of neoplastic and metabolic pathologies affecting bone tissues, antiresorption drugs such as bisphosphonates and monoclonal antibody are used. Bisphosphonates have been linked to cases of ...

    Abstract In the treatment and prevention of osteoporosis and more generally of neoplastic and metabolic pathologies affecting bone tissues, antiresorption drugs such as bisphosphonates and monoclonal antibody are used. Bisphosphonates have been linked to cases of osteonecrosis of the jaws since 2003 by Marx, with more and more evidence over the next two decades; together with bisphosphonate drugs, cases relating to the use of monoclonal drugs have been subsequently added. Among the main independent risk factors, we have extraction procedures in oral surgery that can affect both the mandible and the maxilla and the anterior or posterior sectors. The incidence of MRONJ treated with oral bisphosphonates ranges from 0.5% to 3% according to studies; this incidence would appear to be higher in patients treated with antiresorptive agents with neoplastic diseases. Many pathologies including those in which antiresorptive drugs are used show differences in prevalence in relation to sex; similarly, there could be differences in the incidence of cases of osteonecrosis based on gender in patients undergoing dentoalveolar surgery. Therefore, the objective of this systematic review and trial sequential analysis was to identify and quantify whether there is a proportionally greater risk of MRONJ in male or female subjects and whether there is evidence of greater involvement of osteonecrosis at several extraction sites, differentiating them into mandibular or maxilla and in the anterior or posterior sector. The revision protocol followed the indications of the Cochrane Handbook, and were recorded in Prospero, while the drafting of the manuscript was based on PRISMA. The results of the systematic review, after the study identification and selection process, included a total of 24 studies. The results of the meta-analysis reports: odds ratio (random effects model): 1.476 (0.684, 3.184) between male and female; odds ratio (random effects model): 1.390 (0.801, 2.412) between mandible and maxillary, and an odds ratio value of 0.730 (0.250, ...
    Schlagwörter osteonecrosis ; MRONJ ; BRONJ ; ONJ ; antiresorptive drugs ; Medicine ; R
    Thema/Rubrik (Code) 610
    Sprache Englisch
    Erscheinungsdatum 2023-05-01T00:00:00Z
    Verlag MDPI AG
    Dokumenttyp Artikel ; Online
    Datenquelle BASE - Bielefeld Academic Search Engine (Lebenswissenschaftliche Auswahl)

    Zusatzmaterialien

    Kategorien

  3. Artikel ; Online: Comparative Analysis of Periodontal Pain Using Two Different Orthodontic Techniques, Fixed Multibrackets and Removable Aligners

    Silvia Alcón / Adrián Curto / Mario Alvarado / Alberto Albaladejo / Daniele Garcovich / Alfonso Alvarado-Lorenzo

    Applied Sciences, Vol 11, Iss 12013, p

    A Longitudinal Clinical Study with Monthly Follow-Ups for 12 Months

    2021  Band 12013

    Abstract: The aim of this study was to evaluate the perception of periodontal pain in patients treated with either fixed multibrackets or removable alignment systems with a monthly follow-up over a period of twelve months. Materials and Methods: This longitudinal ... ...

    Abstract The aim of this study was to evaluate the perception of periodontal pain in patients treated with either fixed multibrackets or removable alignment systems with a monthly follow-up over a period of twelve months. Materials and Methods: This longitudinal clinical study comprised a sample of 140 patients (72 women; 68 men) divided into two groups of 70 patients each: the bracket group (BG) with conventional fixed brackets using the MBT technique with a 0.022″ slot and the Invisalign group (IG) with aligners (Invisalign). The visual analog scale (VAS) was used to quantify patient-reported pain. Pain analysis was conducted monthly at 4 (T1), 8 (T2), and 24 h (T3) post-follow-up as well as at 2 (T4), 3 (T5), 4 (T6), 5 (T7), 6 (T8), and 7 days (T9) post-follow-up during the first twelve months after starting orthodontic treatment. Results: Statistically significant differences ( p < 0.05) were observed between both study groups in the mean pain scores on the visual analog scale (VAS) during the twelve-month follow-up period, except for during the eighth month of treatment. In the first month, the group with conventional brackets reported higher pain scores. From the second month onwards, we observed that patients with aligners described a higher level of pain compared to the group of patients with conventional brackets. In both experimental groups, though at different evaluation periods, we found that the peak of maximum pain occurred between 24 and 48 h (T3–T4) after monthly follow-up appointments; from this point, the pain decreased until reaching minimum values from the fifth day onwards (T7). Conclusions: In the first month of treatment, the patients with conventional fixed multibrackets reported the highest levels of pain compared to those with removable aligners. From the second month on, this trend changed. The patients with removable aligners reported the highest levels of pain. Therefore, the orthodontic system used influenced the perception of pain in patients.
    Schlagwörter pain ; orthodontic ; oral health ; aligners ; brackets ; visual analog scale ; Technology ; T ; Engineering (General). Civil engineering (General) ; TA1-2040 ; Biology (General) ; QH301-705.5 ; Physics ; QC1-999 ; Chemistry ; QD1-999
    Thema/Rubrik (Code) 616
    Sprache Englisch
    Erscheinungsdatum 2021-12-01T00:00:00Z
    Verlag MDPI AG
    Dokumenttyp Artikel ; Online
    Datenquelle BASE - Bielefeld Academic Search Engine (Lebenswissenschaftliche Auswahl)

    Zusatzmaterialien

    Kategorien

  4. Artikel ; Online: Reliability of Tooth Width Measurements Delivered by the Clin-Check Pro 6.0 Software on Digital Casts

    Milagros Adobes Martin / Erica Lipani / Laura Bernes Martinez / Alfonso Alvarado Lorenzo / Riccardo Aiuto / Daniele Garcovich

    International Journal of Environmental Research and Public Health, Vol 19, Iss 3581, p

    A Cross-Sectional Study

    2022  Band 3581

    Abstract: The purpose of this study was to assess the accuracy and reliability of tooth width measurements and Bolton Indices delivered by the Clin-Check Pro 6.0 software (Align Technology, San José, CA, USA). Fifty-four plaster casts were selected and measured ... ...

    Abstract The purpose of this study was to assess the accuracy and reliability of tooth width measurements and Bolton Indices delivered by the Clin-Check Pro 6.0 software (Align Technology, San José, CA, USA). Fifty-four plaster casts were selected and measured with a manual calliper by a trained and calibrated observer. The data gathered were compared with those delivered by the software on the corresponding fifty-four virtual casts. The method reliability of the software was assessed by comparing the measurements performed by the software on 201 pairs of clin-checks corresponding to two consecutive treatment phases. Accuracy and reliability were statistically assessed using a mixed model. The software tends to provide larger widths compared with the manual method. Statistically significant differences were found in 23 teeth. At a global level, the mean difference between the methods was −0.19 mm, with a Dahlberg error of 0.24 mm and an intraclass correlation coefficient of 0.98. The Bolton Indices delivered by the two methods had a moderate correlation (ICC = 0.59; 0.69). The within method reliability of the software was extremely high. Tooth width measurements delivered by the software, despite the positive bias, can be considered accurate and clinically acceptable for all teeth except molars. The Bolton Indices made available by the software are not accurate and clinically acceptable, especially in the case of mandibular excess.
    Schlagwörter orthodontic model analysis ; measuring agreement ; digital models ; 3D diagnosis and treatment planning ; Medicine ; R
    Sprache Englisch
    Erscheinungsdatum 2022-03-01T00:00:00Z
    Verlag MDPI AG
    Dokumenttyp Artikel ; Online
    Datenquelle BASE - Bielefeld Academic Search Engine (Lebenswissenschaftliche Auswahl)

    Zusatzmaterialien

    Kategorien

  5. Artikel ; Online: Changes in the Color and Brightness of White Spots Associated with Orthodontic Treatment 6 Months after the Application of Infiltrative Resins

    Hugo Baptista-Sánchez / Laura Antonio-Zancajo / Alberto Albaladejo-Martínez / Pedro Colino Gallardo / Daniele Garcovich / Mario Alvarado-Lorenzo / Alfonso Alvarado-Lorenzo

    International Journal of Environmental Research and Public Health, Vol 19, Iss 9277, p

    Systematic Review and Meta-Analysis

    2022  Band 9277

    Abstract: One of the risks that we find after orthodontic treatment is the secondary appearance of white spot lesions (WLS) after the removal of fixed multi-bracket appliances. Today, there are several treatment methods, resin infiltration being the most used in ... ...

    Abstract One of the risks that we find after orthodontic treatment is the secondary appearance of white spot lesions (WLS) after the removal of fixed multi-bracket appliances. Today, there are several treatment methods, resin infiltration being the most used in the most serious cases. The objective of this study is to carry out a systematic review and meta-analysis to determine the efficacy and stability in the variables of color and gloss, six months after resin infiltration. A comprehensive search was performed in the following databases: PubMed, Embase, Google Scholar, Scopus, Medline, and Web of Science. Articles published in the last 10 years were selected, including in vivo studies with a six-month follow-up. PRISMA guidelines were followed to carry out this systematic review. All studies where the application of resin was performed on carious lesions were discarded. Once the inclusion and exclusion criteria were applied, a final sample of four articles was obtained, on which the review and meta-analysis were carried out. Once examined, all authors considered that there was an immediate improvement in both variables. However, statistically significant differences were obtained in the color change outcome, but not in the brightness outcome in the subgroup analysis after six months of icon resin infiltration.
    Schlagwörter white spot lesion ; orthodontic treatment ; resin infiltration ; lightness ; colour ; Medicine ; R
    Thema/Rubrik (Code) 630
    Sprache Englisch
    Erscheinungsdatum 2022-07-01T00:00:00Z
    Verlag MDPI AG
    Dokumenttyp Artikel ; Online
    Datenquelle BASE - Bielefeld Academic Search Engine (Lebenswissenschaftliche Auswahl)

    Zusatzmaterialien

    Kategorien

  6. Artikel ; Online: A Prospective Randomized Clinical Trial to Evaluate the Slot Size on Pain and Oral Health-Related Quality of Life (OHRQoL) in Orthodontics during the First Month of Treatment with Conventional and Low-Friction Brackets

    Adrian Curto / Alberto Albaladejo / Javier Montero / Mario Alvarado-Lorenzo / Daniele Garcovich / Alfonso Alvarado-Lorenzo

    Applied Sciences, Vol 10, Iss 7136, p

    2020  Band 7136

    Abstract: The aim of this research project was to analyze the influence of slot size and low-friction on pain and the oral health-related quality of life (OHRQoL) of subjects receiving fixed appliances. A group of 120 patients (61 male, 59 female) were chosen for ... ...

    Abstract The aim of this research project was to analyze the influence of slot size and low-friction on pain and the oral health-related quality of life (OHRQoL) of subjects receiving fixed appliances. A group of 120 patients (61 male, 59 female) were chosen for this randomized clinical trial. Participants were classified into four groups (30 patients in each). We compared conventional (C group) and low-friction (LF group) brackets and 0.018″ and 0.022″ slots. Pain was assessed at 4 (T0), 8 (T1), and 24 (T2) hours, and 2 (T3), 3 (T4), 4 (T5), 5 (T6), 6 (T7), and 7 (T8) days after the start of treatment by using the visual analogue scale (VAS). OHRQoL was assessed at 1 month using the Oral Health Impact Profile (OHIP-14). Data was analyzed using the analysis of variance (ANOVA) test with post-hoc Bonferroni correction. For pain on the visual analogue scale, statistically significant differences ( p < 0.05) were found for T0 and T3. For OHRQoL, statistically significant differences ( p < 0.01) were found in the domains of physical pain, psychological discomfort, psychological disability, and overall OHIP. The group with 0.022″ low-friction brackets showed a lower pain score and less impact on OHRQoL. The type of bracket system used and bracket slot size influenced patients’ perceptions of pain and their OHRQoL.
    Schlagwörter pain ; oral health-related quality of life ; orthodontics ; oral health ; Technology ; T ; Engineering (General). Civil engineering (General) ; TA1-2040 ; Biology (General) ; QH301-705.5 ; Physics ; QC1-999 ; Chemistry ; QD1-999
    Thema/Rubrik (Code) 796
    Sprache Englisch
    Erscheinungsdatum 2020-10-01T00:00:00Z
    Verlag MDPI AG
    Dokumenttyp Artikel ; Online
    Datenquelle BASE - Bielefeld Academic Search Engine (Lebenswissenschaftliche Auswahl)

    Zusatzmaterialien

    Kategorien

  7. Artikel ; Online: Comparative Analysis of Periodontal Pain According to the Type of Precision Orthodontic Appliances

    Laura Antonio-Zancajo / Javier Montero / Daniele Garcovich / Mario Alvarado-Lorenzo / Alberto Albaladejo / Alfonso Alvarado-Lorenzo

    Biology, Vol 10, Iss 379, p

    Vestibular, Lingual and Aligners. A Prospective Clinical Study

    2021  Band 379

    Abstract: The objective of this prospective clinical study was to analyze the pain (intensity, location and type) that patients presented after the placement of different types of orthodontic appliances: conventional, low friction, lingual and aligners. The sample ...

    Abstract The objective of this prospective clinical study was to analyze the pain (intensity, location and type) that patients presented after the placement of different types of orthodontic appliances: conventional, low friction, lingual and aligners. The sample consisted of 120 patients divided into four groups: conventional (CON), low friction (LF), lingual (LO) and aligners (INV). The participants were given the Short-Form McGill Pain Questionnaire (Ortho-SF-MPQ), where they had to record the pain intensity (no pain, mild, moderate or intense) and the periodontal location at different time points, from the first 4 h to 7 days after the start of treatment. In all the study groups, the most frequent location was both anterior arches, with maximum values between 56.7% (CON group at 24 h) and 30% (LO group at 4 h). The “whole mouth” and “complete lower arch” locations were indicated only by the patients in the lingual group. Regarding pain intensity, the patients reported a higher percentage of mild–moderate pain during the first 3 days of treatment (96.7% in LO at 4 h, 86.7% in CON, 83.3% in LF and 90% in INV at 24 h); later, the reported pain decreased to no pain/mild pain, especially in the lingual group, until reaching values close to zero at 7 days post-treatment. The most frequent type of pain was acute in the low friction and lingual groups (with maxima of 60% and 46.7% at 24 h, respectively). On the contrary, in the conventional (36.7% at 4 h) and Invisalign (40% at 24 h) groups, the sensitive type was the most frequent. There are differences regarding periodontal pain in its intensity, location and type according to the use of different orthodontic techniques.
    Schlagwörter orthodontics ; pain ; location ; degree of pain ; low-friction brackets ; lingual orthodontics ; Biology (General) ; QH301-705.5
    Thema/Rubrik (Code) 616
    Sprache Englisch
    Erscheinungsdatum 2021-04-01T00:00:00Z
    Verlag MDPI AG
    Dokumenttyp Artikel ; Online
    Datenquelle BASE - Bielefeld Academic Search Engine (Lebenswissenschaftliche Auswahl)

    Zusatzmaterialien

    Kategorien

  8. Artikel ; Online: Tip and Torque Accuracy According to the ISO 27020:2019 Norm in Currently Available Pre-Adjusted Orthodontic Brackets

    Laura Bernes Martinez / Daniele Garcovich / Alfonso Alvarado Lorenzo / Angel Zhou Wu / Riccardo Aiuto / Milagros Adobes Martin

    Applied Sciences, Vol 11, Iss 11657, p

    2021  Band 11657

    Abstract: Background: The precision of bracket manufacturing is fundamental to ensure the correct expression of the inbuilt information. The objective of this study was to determine the actual tip and torque values of a pool of stainless steel brackets, pre- ... ...

    Abstract Background: The precision of bracket manufacturing is fundamental to ensure the correct expression of the inbuilt information. The objective of this study was to determine the actual tip and torque values of a pool of stainless steel brackets, pre-adjusted according to the MBT prescription values, and to compare these actual values with those stated by the manufacturers in order to test their compliance with the tolerance limits reported in the ISO 27020:2019. Methods: A sample of 360 stainless steel brackets, from 12 different providers, were evaluated. All brackets had a nominal slot size of 0.022 in., belonged to the upper right central incisor, and were manufactured with the metal injection molding technique (MIM). For each provider, three different batches of the same bracket series were tested. A single-blind design was used for bracket coding. Results: Only five systems displayed torque mean values that matched the declared values ( p > 0.05). Only one system did not respect the tolerance limits established in the ISO 27020:2019 norm. The tip values were different from those declared in seven of the assessed systems; however, none exceeded the tolerance limits. The inter-batch variability in most cases was not statistically significant. Conclusions: In most of the assessed systems, there can be a difference between the actual and the declared torque values, while tip information is usually accurately incorporated into the bracket slot. Lack of precision in the manufacturing process can reduce the efficacy of the appliance and force the clinician to compensate for dimensional inaccuracy through wire bending.
    Schlagwörter orthodontic brackets ; torque values ; tip values ; angulation values ; ISO standard ; manufacturing accuracy ; Technology ; T ; Engineering (General). Civil engineering (General) ; TA1-2040 ; Biology (General) ; QH301-705.5 ; Physics ; QC1-999 ; Chemistry ; QD1-999
    Thema/Rubrik (Code) 600
    Sprache Englisch
    Erscheinungsdatum 2021-12-01T00:00:00Z
    Verlag MDPI AG
    Dokumenttyp Artikel ; Online
    Datenquelle BASE - Bielefeld Academic Search Engine (Lebenswissenschaftliche Auswahl)

    Zusatzmaterialien

    Kategorien

  9. Artikel ; Online: The Influence of Friction on Design of the Type of Bracket and Its Relation to OHRQoL in Patients Who Use Multi-Bracket Appliances

    Adriana González-Sáez / Laura Antonio-Zancajo / Javier Montero / Alberto Albaladejo / María Melo / Daniele Garcovich / Alfonso Alvarado-Lorenzo

    Medicina, Vol 57, Iss 171, p

    A Randomized Clinical Trial

    2021  Band 171

    Abstract: Background and objectives: The aim of this study was to evaluate the influence of friction on design of the type of bracket, patients’ perception of pain and the impact on their oral health-related quality of life. Materials and Methods: A randomized ... ...

    Abstract Background and objectives: The aim of this study was to evaluate the influence of friction on design of the type of bracket, patients’ perception of pain and the impact on their oral health-related quality of life. Materials and Methods: A randomized clinical trial was carried out with 90 patients (62.2% women and 37.8% men) with three kinds of fixed multi-bracket appliances: Conventional (GC), fixed multi-bracket low friction (GS) and self-ligating (GA). The VAS (Visual Analogue Scale) was used to determine pain during the first seven days of treatment at different points in time. The patients were also given the OHIP-14 (Oral Health Impact Profile) questionnaire to analyse their oral health-related quality of life (OHRQoL) after the first 30 days of treatment. The ANOVA test was used for the analysis of the variables and the post hoc Bonferroni test for the comparison between groups. Results: Maximum pain was observed between one and two days after the start of treatment. The GC group showed the greatest degree of pain, with maximum values (4.5 ± 2.0) at 24 h. The self-ligation brackets show lower impact on patients’ oral health-related quality of life (0.8 ± 2.2, p < 0.01). Conclusions: Friction in the type of bracket influences pain and the Oral Health-Related Quality of Life of patients who use multi-bracket fixed orthodontics.
    Schlagwörter orthodontics ; pain ; quality of life ; low-friction brackets ; oral health ; Medicine (General) ; R5-920
    Thema/Rubrik (Code) 796
    Sprache Englisch
    Erscheinungsdatum 2021-02-01T00:00:00Z
    Verlag MDPI AG
    Dokumenttyp Artikel ; Online
    Datenquelle BASE - Bielefeld Academic Search Engine (Lebenswissenschaftliche Auswahl)

    Zusatzmaterialien

    Kategorien

  10. Artikel ; Online: Compliance with the ISO 27020:2019 norm of a sample of currently available preadjusted Orthodontic bracket systems. Are the actual dimensions as expected?

    Laura Bernés Martínez / Daniele Garcovich / Pilar España Pamplona / Milagros Adobes Adobes Martín / Alfonso Alvarado Lorenzo

    Head & Face Medicine, Vol 17, Iss 1, Pp 1-

    2021  Band 10

    Abstract: Abstract Background Determine the exact slot dimension of a sample of a MBT prescription stainless steel conventional brackets from different manufacturers to compare the actual values with the nominal ones declared by the manufacturers and to verify the ...

    Abstract Abstract Background Determine the exact slot dimension of a sample of a MBT prescription stainless steel conventional brackets from different manufacturers to compare the actual values with the nominal ones declared by the manufacturers and to verify the compliance with tolerance limits given by the ISO 27020:2019. Different batches from each manufacturer were evaluated to determine whether or not they are different in size. In addition, the geometry of the slot walls was assessed. Methods 360 stainless steel preadjusted orthodontic brackets of 12 different manufacturers were assessed. All brackets had a nominal slot size of 0.022 by 0.028 inches, belonged to the right upper central incisor, and were fabricated with the metal injection molding technique (MIM). For each manufacturer, three different manufacturing batches were evaluated. Brackets were coded using a single-blind design. Results All bracket systems in the study group except one displayed a statistically significant difference with the nominal declared value, although only four of the systems did not comply with the tolerance limits established by the ISO 27020:2019. In most of the systems, the slot height was oversized when compared to the nominal one. A significant interbatch variability was found in most of the evaluated systems. Most of the brackets walls were divergent. Conclusions The dimensional accuracy of commercially available metal brackets is not guaranteed. The respect for the norm should be enforced as well as the quality controls along the manufacturing process since orthodontic brackets are a precision medical device.
    Schlagwörter Orthodontic Brackets ; Slot parallelism ; Slot dimension ; ISO standard ; Machining accuracy ; Specialties of internal medicine ; RC581-951
    Thema/Rubrik (Code) 600
    Sprache Englisch
    Erscheinungsdatum 2021-07-01T00:00:00Z
    Verlag BMC
    Dokumenttyp Artikel ; Online
    Datenquelle BASE - Bielefeld Academic Search Engine (Lebenswissenschaftliche Auswahl)

    Zusatzmaterialien

    Kategorien

Zum Seitenanfang