LIVIVO - The Search Portal for Life Sciences

zur deutschen Oberfläche wechseln
Advanced search

Search results

Result 1 - 2 of total 2

Search options

  1. Article: Comparative evaluation of continuous infusion versus programmed intermittent bolus techniques in erector spinae plane block in modified radical mastectomy - A preliminary randomised controlled trial.

    Datchinamourthy, Thamizharasan / Bhoi, Debesh / Chhabra, Anjolie / Mohan, Virender K / Kumar, Kanil R / Ranganathan, Poornima

    Indian journal of anaesthesia

    2024  Volume 68, Issue 3, Page(s) 273–279

    Abstract: Background and aims: Single-shot erector spinae plane block (ESPB) provides excellent analgesia in mastectomy in the immediate post-operative period but is not sufficient to maintain for prolonged duration. This study compares the efficacy of programmed ...

    Abstract Background and aims: Single-shot erector spinae plane block (ESPB) provides excellent analgesia in mastectomy in the immediate post-operative period but is not sufficient to maintain for prolonged duration. This study compares the efficacy of programmed intermittent bolus (PIB) versus continuous infusion (CI) techniques after ESPB by placing a catheter for mastectomy.
    Methods: After ethical approval and patient consent, ESPB was performed at the T4 level in 50 patients with an initial bolus of 20 mL 0.375% ropivacaine and a catheter placed 30 min before surgery. In the postoperative period, they were randomised to Group I - intermittent bolus of 20 mL 0.2% ropivacaine every 4 h for 24 h and Group C - continuous infusion of 0.2% ropivacaine at 5 mL/h for 24 h. The primary outcome was the 24-h fentanyl consumption by patient-controlled analgesia device. Data was analysed using Stata 14.0.
    Results: Group I patients had reduced post-operative fentanyl consumption {mean [standard deviation (SD)]: 166 (139.17) µg vs 332 (247.96) µg,
    Conclusion: The PIB technique after ESPB provides decreased postoperative opioid consumption, better post-operative analgesia and quality of recovery compared to the CI technique in patients undergoing mastectomy.
    Language English
    Publishing date 2024-02-22
    Publishing country India
    Document type Journal Article
    ZDB-ID 412570-8
    ISSN 0019-5049
    ISSN 0019-5049
    DOI 10.4103/ija.ija_922_23
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  2. Article: Returns of micro bubble air contrast: A technique to improve ultrasound visibility of continuous catheter.

    Bhoi, Debesh / Datchinamourthy, Thamizharasan / Kalagara, Reshma / Rani, Poonam

    Journal of anaesthesiology, clinical pharmacology

    2022  Volume 38, Issue 3, Page(s) 509–510

    Language English
    Publishing date 2022-04-12
    Publishing country India
    Document type Journal Article
    ZDB-ID 1401760-x
    ISSN 0970-9185
    ISSN 0970-9185
    DOI 10.4103/joacp.JOACP_228_20
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

To top