LIVIVO - The Search Portal for Life Sciences

zur deutschen Oberfläche wechseln
Advanced search

Search results

Result 1 - 5 of total 5

Search options

  1. Article ; Online: Sars-Cov-2, Covid-19 Et Œil: Le Point Sur Les Données Publiées

    Rousseau, Antoine / Fenolland, Jean-Rémi / Labetoulle, Marc

    J Fr Ophtalmol

    Abstract: Abstract The COVID-19 pandemic has dramatically changed our daily lives as ophthalmologists. This general review firstly provides a better understanding of the virus responsible for the pandemic: the SARS-CoV-2, and the clinical manifestations of the ... ...

    Abstract Abstract The COVID-19 pandemic has dramatically changed our daily lives as ophthalmologists. This general review firstly provides a better understanding of the virus responsible for the pandemic: the SARS-CoV-2, and the clinical manifestations of the COVID-19 disease. The second part is detailing the pathophysiology, clinical signs and challenges of ocular involvement, which seems rare and not functionally severe, but which may be a potential source of contamination. Finally, we discuss the preventive measures that need to be implemented in our daily practice to avoid any viral dissemination.
    Keywords covid19
    Publisher Elsevier; PMC; WHO
    Document type Article ; Online
    Note WHO #Covidence: #436339
    DOI 10.1016/j.jfo.2020.05.003
    Database COVID19

    Kategorien

  2. Article ; Online: Inadvertent Subconjunctival Injection of a Dexamethasone Implant.

    Fenolland, Jean-Remi / Sigaux, Mickael / Giraud, Jean-Marie

    JAMA ophthalmology

    2017  Volume 135, Issue 5, Page(s) e170106

    MeSH term(s) Conjunctiva/drug effects ; Corneal Diseases/chemically induced ; Corneal Diseases/diagnosis ; Device Removal ; Dexamethasone/adverse effects ; Drug Implants ; Endothelium, Corneal/drug effects ; Glucocorticoids/adverse effects ; Humans ; Injections, Intraocular ; Macular Edema/drug therapy ; Male ; Middle Aged ; Vision Disorders/chemically induced ; Vision Disorders/diagnosis ; Visual Acuity/drug effects
    Chemical Substances Drug Implants ; Glucocorticoids ; Dexamethasone (7S5I7G3JQL)
    Language English
    Publishing date 2017-05-11
    Publishing country United States
    Document type Journal Article
    ZDB-ID 2701705-9
    ISSN 2168-6173 ; 2168-6165
    ISSN (online) 2168-6173
    ISSN 2168-6165
    DOI 10.1001/jamaophthalmol.2017.0106
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  3. Article ; Online: Improving event-based progression analysis in glaucomatous visual fields.

    Rui, Chiara / Montesano, Giovanni / Crabb, David P / Brusini, Paolo / Chauhan, Balwantray C / Rossetti, Luca M / Fogagnolo, Paolo / Giraud, Jean-Marie / Fenolland, Jean-Rémi / Oddone, Francesco

    Scientific reports

    2021  Volume 11, Issue 1, Page(s) 16353

    Abstract: Glaucoma is a progressive optic neuropathy with characteristic changes to the optic nerve head and the visual field (VF). Detecting progression of VF damage with Standard Automated Perimetry (SAP) is of paramount importance for clinical care. One common ... ...

    Abstract Glaucoma is a progressive optic neuropathy with characteristic changes to the optic nerve head and the visual field (VF). Detecting progression of VF damage with Standard Automated Perimetry (SAP) is of paramount importance for clinical care. One common approach to detecting progression is to compare each new VF test to a baseline SAP test (event analysis). This comparison is made difficult by the test-retest variability of SAP, which increases with the level of VF damage, and the limited range of measurement, meaning that damage cannot be assessed below a certain level. We performed a prospective international multi-centre data collection of SAP data on 90 eyes from 90 people with glaucoma and different levels of VF damage over a short period of time (6 tests in 60 days). Data were collected using a fundus tracked perimeter (Compass, CenterVue). We used these data (minus the first test) to develop an improved event analysis that accounts for both the change in variability with damage and the lower bound on the measurement imposed by SAP. Using simulations, we show that our approach is more sensitive compared to previously developed methods, especially in the case of advanced glaucoma, while retaining similar specificity.
    MeSH term(s) Aged ; Eye/pathology ; Female ; Glaucoma/diagnosis ; Glaucoma/pathology ; Humans ; Intraocular Pressure/physiology ; Male ; Middle Aged ; Optic Disk/pathology ; Optic Nerve Diseases/diagnosis ; Optic Nerve Diseases/pathology ; Prospective Studies ; Vision Disorders/diagnosis ; Vision Disorders/pathology ; Visual Field Tests/methods ; Visual Fields/physiology
    Language English
    Publishing date 2021-08-11
    Publishing country England
    Document type Journal Article ; Multicenter Study ; Research Support, Non-U.S. Gov't
    ZDB-ID 2615211-3
    ISSN 2045-2322 ; 2045-2322
    ISSN (online) 2045-2322
    ISSN 2045-2322
    DOI 10.1038/s41598-021-95877-9
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  4. Article ; Online: Syphilitic Scleritis.

    Fénolland, Jean-Rémi / Bonnel, Samantha / Rambaud, Camille / Froussart-Maille, Françoise / Rigal-Sastourné, Jean-Claude

    Ocular immunology and inflammation

    2016  Volume 24, Issue 1, Page(s) 93–95

    Abstract: A 47-year-old man developed a painful right red eye for 72 hours with a 20/25 decreased visual acuity. He had no medical history. Slit-lamp examination revealed a painful nodular scleritis at the equator of the globe in the infero-temporal quadrant. ... ...

    Abstract A 47-year-old man developed a painful right red eye for 72 hours with a 20/25 decreased visual acuity. He had no medical history. Slit-lamp examination revealed a painful nodular scleritis at the equator of the globe in the infero-temporal quadrant. There was a moderate intraocular inflammation in the anterior segment. Fundus examination revealed a grade 1 hyalitis and a focal retinitis with vasculitis and arterio-veinous occlusion toward the scleritis zone. Syphilis and HIV serology were positive and the scleritis resolved 5 days after a penicillin G medication. Syphilitic scleritis are relatively uncommon.
    MeSH term(s) Anti-Bacterial Agents/therapeutic use ; Eye Infections, Bacterial/diagnosis ; Eye Infections, Bacterial/drug therapy ; Eye Infections, Bacterial/microbiology ; Fluorescein Angiography ; Humans ; Male ; Middle Aged ; Penicillin G/therapeutic use ; Retinal Artery Occlusion/diagnosis ; Retinal Artery Occlusion/drug therapy ; Retinal Artery Occlusion/microbiology ; Retinal Vasculitis/diagnosis ; Retinal Vasculitis/drug therapy ; Retinal Vasculitis/microbiology ; Retinal Vein Occlusion/diagnosis ; Retinal Vein Occlusion/drug therapy ; Retinal Vein Occlusion/microbiology ; Retinitis/diagnosis ; Retinitis/drug therapy ; Retinitis/microbiology ; Scleritis/diagnosis ; Scleritis/drug therapy ; Scleritis/microbiology ; Syphilis/diagnosis ; Syphilis/drug therapy ; Syphilis/microbiology ; Syphilis Serodiagnosis
    Chemical Substances Anti-Bacterial Agents ; Penicillin G (Q42T66VG0C)
    Language English
    Publishing date 2016
    Publishing country England
    Document type Case Reports ; Letter
    ZDB-ID 1193873-0
    ISSN 1744-5078 ; 0927-3948
    ISSN (online) 1744-5078
    ISSN 0927-3948
    DOI 10.3109/09273948.2014.916307
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  5. Article ; Online: Reproducibility of macular ganglion cell-inner plexiform layer thickness measurement with cirrus HD-OCT in normal, hypertensive and glaucomatous eyes.

    Francoz, Marlène / Fenolland, Jean-Rémi / Giraud, Jean-Marie / El Chehab, Hussam / Sendon, Damien / May, Franck / Renard, Jean-Paul

    The British journal of ophthalmology

    2013  Volume 98, Issue 3, Page(s) 322–328

    Abstract: Aim: To evaluate the intraobserver and interobserver reproducibility of macular retinal ganglion cell-inner plexiform layer (GC-IPL) thickness measurement by automated detection on Optical Coherence Tomography (OCT) images in normal, hypertensive ( ... ...

    Abstract Aim: To evaluate the intraobserver and interobserver reproducibility of macular retinal ganglion cell-inner plexiform layer (GC-IPL) thickness measurement by automated detection on Optical Coherence Tomography (OCT) images in normal, hypertensive (ocular hypertensive (OHT)) and glaucomatous eyes.
    Methods: A total of 138 eyes were enrolled in three groups: 69 normal, 35 OHT and 34 primary open-angle glaucoma eyes. All patients underwent a complete ocular examination, 24-2 automated perimetry, biometry and pachymetry. Macular imaging was performed in each eye using the Cirrus HD-OCT 4000 with software V.6.0. (Carl Zeiss Meditec, Dublin, California, USA) three times on the same day by each of two observers, and the GC analysis (GCA) algorithm provided parameters expressed as average, minimum and six sectoral GC-IPL thicknesses. Reproducibility was assessed by intraclass correlation coefficient (ICC), coefficient of variation (CV) and test-retest variability (TRTV) calculated as 1.96 times the SD.
    Results: Mean GC-IPL thickness was 82.27 ± 7.37 μm, 76.84 ± 7.01 μm and 66.16 ± 11.16 μm in normal, OHT and glaucoma groups, respectively. GC-IPL thickness was significantly lower in glaucomatous eyes than in normal and OHT eyes (p<0.0001 for all parameters). In all groups, ICC ranged from 96.4 to 99.9% and 92.5 to 99.8%, CV ranged from 0.41 to 2.24% and 0.55 to 1.67%, and TRTV ranged from 0.61 to 2.64 μm and 0.83 to 2.22 μm for intraobserver and interobserver reproducibility, respectively.
    Conclusions: To the best of our knowledge, this is the first study of GCA algorithm reproducibility in normal, OHT and glaucomatous eyes. The reproducibility of GC-IPL thickness measurements using the Cirrus HD-OCT GCA algorithm was found to be highly satisfactory. GC-IPL thickness may be a promising new OCT parameter for analysis of ganglion cell damage in glaucoma.
    MeSH term(s) Adult ; Aged ; Aged, 80 and over ; Algorithms ; Biometry ; Female ; Glaucoma, Open-Angle/diagnosis ; Healthy Volunteers ; Humans ; Intraocular Pressure ; Macula Lutea ; Male ; Middle Aged ; Nerve Fibers/pathology ; Observer Variation ; Ocular Hypertension/diagnosis ; Optic Disk/pathology ; Optic Nerve Diseases/diagnosis ; Reproducibility of Results ; Retinal Ganglion Cells/pathology ; Tomography, Optical Coherence/methods ; Tonometry, Ocular
    Language English
    Publishing date 2013-12-04
    Publishing country England
    Document type Journal Article
    ZDB-ID 80078-8
    ISSN 1468-2079 ; 0007-1161
    ISSN (online) 1468-2079
    ISSN 0007-1161
    DOI 10.1136/bjophthalmol-2012-302242
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

To top