LIVIVO - The Search Portal for Life Sciences

zur deutschen Oberfläche wechseln
Advanced search

Your last searches

  1. AU="Figueroa, Andres V"
  2. AU="Racca, C."
  3. AU="Slavu, Diana-Maria"
  4. AU="Talbert, Emily"
  5. AU=Abdelnour Loay H
  6. AU=Meisburger Steve P.
  7. AU="Silveira, Fernando A. O."
  8. AU="Toru Nabika"
  9. AU="Vojkovic, Marina"
  10. AU="Gaier, Eric D"
  11. AU="Chandler Crews"
  12. AU="Comte, Marie-Hélène"
  13. AU="Cohen, Or"
  14. AU="Abdellatifi, Mohamed"
  15. AU="Luebbe, Elizabeth"
  16. AU="Emidio, Adriana"
  17. AU=Masmejan Sophie
  18. AU="Samantha Ridley"
  19. AU="Moghaddam-Alvandi, Arash"
  20. AU="Khanolkar, Amey R."
  21. AU="Vasquez Martinez, Rodolfo"
  22. AU="Morgan, E"

Search results

Result 1 - 3 of total 3

Search options

  1. Article: Up and over staged endoconduit technique for endovascular aortic aneurysm repair.

    Figueroa, Andres V / Tanenbaum, Mira T / Costa-Filho, Jose Eduardo / Gonzalez, Marilisa S / Baig, Mirza S / Timaran, Carlos H

    Journal of vascular surgery cases and innovative techniques

    2024  Volume 10, Issue 3, Page(s) 101449

    Abstract: Adverse iliofemoral anatomy can preclude complex endovascular aortic aneurysm repair. This study aims to describe the "up-and-over" staged endoconduit technique to improve access and avoid vascular injury before complex endovascular aneurysm repair. A ... ...

    Abstract Adverse iliofemoral anatomy can preclude complex endovascular aortic aneurysm repair. This study aims to describe the "up-and-over" staged endoconduit technique to improve access and avoid vascular injury before complex endovascular aneurysm repair. A staged procedure for complex endovascular aortic aneurysm repair is performed using an endoconduit (W.L. Gore & Associates). After obtaining contralateral femoral access, the extension of iliofemoral disease is assessed using angiography. The endoconduit is advanced "up and over" the aortic bifurcation and delivered percutaneously into the common femoral artery to treat a diseased access site and maintain intact the ipsilateral femoral access for future stent graft deployment. Internal iliac artery patency is maintained when feasible. During complex aneurysm repair, the endoconduit is accessed directly under ultrasound guidance using sequential dilation to avoid vascular injury. PerClose sutures (Abbott Vascular) are used to close the endoconduit femoral access site. This study found that staged "up and over" endoconduit creation is a useful technique before complex endovascular aneurysm repair in patients with adverse iliofemoral anatomy. Avoiding accessing the main femoral access site during the first stage prevents vascular or access site injuries and allows for both iliac and femoral disease to be addressed.
    Language English
    Publishing date 2024-02-13
    Publishing country United States
    Document type Journal Article
    ISSN 2468-4287
    ISSN 2468-4287
    DOI 10.1016/j.jvscit.2024.101449
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  2. Article: Early results of transcatheter electrosurgical aortic septotomy for endovascular repair of chronic dissecting aortoiliac aneurysms.

    Tanenbaum, Mira T / Figueroa, Andres V / Lee, K Benjamin / Costa Filho, Jose Eduardo / Gonzalez, Marilisa Soto / Baig, Mirza S / Timaran, Carlos H

    Journal of vascular surgery cases and innovative techniques

    2024  Volume 10, Issue 3, Page(s) 101467

    Abstract: Objective: Endovascular repair of chronic dissecting aortoiliac aneurysms is challenging given the rigid septum, compressed true lumen (TL), and target vessels frequently originating in the false lumen. We have used transcatheter electrosurgical aortic ... ...

    Abstract Objective: Endovascular repair of chronic dissecting aortoiliac aneurysms is challenging given the rigid septum, compressed true lumen (TL), and target vessels frequently originating in the false lumen. We have used transcatheter electrosurgical aortic septotomy (TEAS) before stent graft implantation under intravascular ultrasound (IVUS) and fusion guidance. The purpose of this study is to assess the outcomes of TEAS during complex endovascular repair of dissecting aneurysms.
    Methods: From 2021 to 2023, 17 patients underwent TEAS. The primary end point was technical success, with secondary end points of proximal and distal seals, target vessel instability, aortic and iliac TL and cross-sectional area (CSA) expansion, and aortic-related death. During the procedure, the aortic septum is crossed through a pre-existing entry or via electrocautery-activated 0.018-in. Astato XS20 wire (Asahi-Intecc) under IVUS and fusion guidance. The penetrated wire is then snared in the false lumen and pulled through the ipsilateral femoral access. A 1-cm length of the middle of the Astato wire coating is kinked in a three-sided polygonal configuration, denuded the inner surface of the wire using a no. 15 blade, and positioned at the apex of the septum. Both ends of the Astato wire are insulated with 0.018-in. microcatheters, and the back end of the wire is denuded and connected to cautery. Gentle traction is applied to the wire, and short bursts of electrocautery cutting are applied at 60 to 80 W.
    Results: The technical success of the septotomy was 100%. No incidence of visceral or lower extremity malperfusion, vascular injury, or distal embolization occurred. Of the 17 patients, 4 underwent thoracic endovascular aneurysm repair, 2 underwent endovascular aortic repair, and 11 underwent fenestrated/branched endovascular aneurysm repair after septotomy. All target vessels were successfully stented. A distal landing zone seal with exclusion of the false lumen was achieved in 16 of the 17 patients (94.1%). One patient required embolization of the false lumen of the celiac artery after septotomy. The TL mean diameter and CSA of the descending thoracic aorta after septotomy was expanded by 7.01 ± 1.9 mm (relative mean diameter expansion, 42.3%;
    Conclusions: The use of IVUS and fusion-guided TEAS offers a promising technique to facilitate TL expansion and false lumen exclusion in chronic dissecting aortic aneurysms before repair. The durability and long-term outcomes of this technique in a larger cohort remain to be elucidated.
    Language English
    Publishing date 2024-02-29
    Publishing country United States
    Document type Journal Article
    ISSN 2468-4287
    ISSN 2468-4287
    DOI 10.1016/j.jvscit.2024.101467
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  3. Article ; Online: Long-term outcomes of staged iliofemoral endoconduits prior to complex endovascular aortic aneurysm repair.

    Figueroa, Andres V / Tanenbaum, Mira T / Costa Filho, Jose Eduardo / Gonzalez, Marilisa Soto / Coronel, Natalia I / Baig, Mirza S / Timaran, Carlos H

    Journal of vascular surgery

    2024  

    Abstract: Objective: Adverse iliofemoral anatomy may preclude complex endovascular aortic aneurysm repair (EVAR). In our practice, staged iliofemoral endoconduits (ECs) are planned prior to complex EVAR to improve vascular access and decrease operative time while ...

    Abstract Objective: Adverse iliofemoral anatomy may preclude complex endovascular aortic aneurysm repair (EVAR). In our practice, staged iliofemoral endoconduits (ECs) are planned prior to complex EVAR to improve vascular access and decrease operative time while allowing the stented vessel to heal. This study describes the long-term results of iliofemoral ECs prior to complex EVAR.
    Methods: Between 2012 and 2023, 59 patients (44% male; median age, 75 ± 6 years) underwent ECs before complex EVAR using self-expanding covered stents (Viabahn). For common femoral artery (CFA) disease, ECs were delivered percutaneously from contralateral femoral access and extended into the CFA to preserve the future access site for stent graft delivery. Internal iliac artery patency was maintained when feasible. During complex EVAR, the EC extended into the CFA was directly accessed and sequentially dilated until it could accommodate the endograft. Technical success was defined as successful access, closure, and delivery of the endograft during complex EVAR. Endpoints were vascular injury or EC disruption, secondary interventions, and EC patency.
    Results: Unilateral EC was performed in 45 patients (76%). ECs were extended into the CFA in 21 patients (35%). Median diameters of the native common iliac, external iliac, and CFA were 7 mm (interquartile range [IQR], 6-8 mm), 6 mm (IQR, 5-7 mm), and 6 mm (IQR, 6-7 mm), respectively. Internal iliac artery was inadvertently excluded in 10 patients (17%). Six patients (10%) had an intraoperative vascular injury during the EC procedure, and six patients (10%) had EC disruption during complex EVAR, including five EC collapses requiring re-stenting and one EC fracture requiring open cut-down and reconstruction with patch angioplasty. In 23 patients (39%), 22 Fr OD devices were used; 20 Fr were used in 22 patients (37%), and 18 Fr in 14 patients (24%). Technical success for accessing EC was 89%. There was no difference in major adverse events at 30 days between the iliac ECs and iliofemoral ECs. Primary patency by Kaplan-Meier estimates at 1, 3, and 5 years were 97.5%, 89%, and 82%, respectively. There was no difference in primary patency between iliac and iliofemoral ECs. Six secondary interventions (10%) were required. The mean follow-up was 34 ± 27 months; no limb loss or amputations occurred during the follow-up.
    Conclusions: ECs improve vascular access, and their use prior to complex EVAR is associated with low rates of vascular injury, high technical success, and optimal long-term patency. Complex EVAR procedures can be performed percutaneously by accessing the EC directly under ultrasound guidance and using sequential dilation to avoid EC disruption.
    Language English
    Publishing date 2024-02-07
    Publishing country United States
    Document type Journal Article
    ZDB-ID 605700-7
    ISSN 1097-6809 ; 0741-5214
    ISSN (online) 1097-6809
    ISSN 0741-5214
    DOI 10.1016/j.jvs.2024.02.001
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

To top