  1. Article ; Online: Monte Carlo and experimental evaluation of a Timepix4 compact gamma camera for coded aperture nuclear medicine imaging with depth resolution.

    Cerbone, Laura Antonia / Cimmino, Luigi / Sarno, Antonio / Biesuz, Nicolò Vladi / Bolzonella, Riccardo / Mettivier, Giovanni / Fiorini, Massimiliano / Russo, Paolo

    Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB)

    2023  Volume 113, Page(s) 102663

    Abstract: Purpose: We designed a prototype compact gamma camera (MediPROBE4) for nuclear medicine tasks, including radio-guided surgery and sentinel lymph node imaging with a : Methods: The hand-held camera (1 kg weight) is based on a Timepix4 readout circuit ... ...

    Abstract Purpose: We designed a prototype compact gamma camera (MediPROBE4) for nuclear medicine tasks, including radio-guided surgery and sentinel lymph node imaging with a
    Methods: The hand-held camera (1 kg weight) is based on a Timepix4 readout circuit for photon-counting, energy-sensitive, hybrid pixel detectors (24.6 × 28.2 mm
    Results: Geant4 MC simulations showed that, for a
    Conclusions: MC simulations and validation lab tests showed the expected performance of the MediPROBE4 compact gamma camera for gamma-ray 3D imaging.
    MeSH term(s) Gamma Cameras ; Nuclear Medicine ; Cadmium Compounds ; Silicon ; Quantum Dots ; Tellurium
    Chemical Substances cadmium telluride (STG188WO13) ; Cadmium Compounds ; Silicon (Z4152N8IUI) ; Tellurium (NQA0O090ZJ)
    Language English
    Publishing date 2023-09-05
    Publishing country Italy
    Document type Journal Article
    ZDB-ID 1122650-x
    ISSN 1724-191X ; 1120-1797
    ISSN (online) 1724-191X
    ISSN 1120-1797
    DOI 10.1016/j.ejmp.2023.102663
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  2. Article: High-efficiency deflection of high-energy protons through axial channeling in a bent crystal.

    Scandale, Walter / Vomiero, Alberto / Baricordi, Stefano / Dalpiaz, Pietro / Fiorini, Massimiliano / Guidi, Vincenzo / Mazzolari, Andrea / Della Mea, Gianantonio / Milan, Riccardo / Ambrosi, Giovanni / Bertucci, Bruna / Burger, William J / Zuccon, Paolo / Cavoto, Gianluca / Luci, Claudio / Santacesaria, Roberta / Valente, Paolo / Vallazza, Erik / Afonin, Alexander G /
    Chesnokov, Yury A / Maisheev, Vladimir A / Yazynin, Igor A / Kovalenko, Alexander D / Taratin, Alexander M / Denisov, Alexander S / Gavrikov, Yury A / Ivanov, Yuri M / Lapina, Lyubov P / Malyarenko, Liudmila G / Skorobogatov, Vyacheslav V / Suvorov, Vsevolod M / Vavilov, Sergey A / Bolognini, Davide / Hasan, Said / Mozzanica, Aldo / Prest, Michela

    Physical review letters

    2008  Volume 101, Issue 16, Page(s) 164801

    Abstract: Beam deflection due to axial channeling in a silicon crystal bent along the 111 axis was observed with 400 GeV/c protons at the CERN Super Proton Synchrotron. The condition for doughnut scattering of protons by the atomic strings of the crystal was ... ...

    Abstract Beam deflection due to axial channeling in a silicon crystal bent along the 111 axis was observed with 400 GeV/c protons at the CERN Super Proton Synchrotron. The condition for doughnut scattering of protons by the atomic strings of the crystal was attained. Such a condition allowed one to observe a beam deflection of 50 murad with about 30% efficiency. The contribution of hyperchanneled states of protons to the observed beam deflection was less than 2% according to simulation results.
    Language English
    Publishing date 2008-10-17
    Publishing country United States
    Document type Journal Article
    ZDB-ID 208853-8
    ISSN 1079-7114 ; 0031-9007
    ISSN (online) 1079-7114
    ISSN 0031-9007
    DOI 10.1103/PhysRevLett.101.164801
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  3. Article: Apparatus to study crystal channeling and volume reflection phenomena at the SPS H8 beamline.

    Scandale, Walter / Efthymiopoulos, Ilias / Still, Dean A / Carnera, Alberto / Della Mea, Gianantonio / De Salvador, Davide / Milan, Riccardo / Vomiero, Alberto / Baricordi, Stefano / Chiozzi, Stefano / Dalpiaz, Pietro / Damiani, Chiara / Fiorini, Massimiliano / Guidi, Vincenzo / Martinelli, Giuliano / Mazzolari, Andrea / Milan, Emiliano / Ambrosi, Giovanni / Azzarello, Philipp /
    Battiston, Roberto / Bertucci, Bruna / Burger, William J / Ionica, Maria / Zuccon, Paolo / Cavoto, Gianluca / Santacesaria, Roberta / Valente, Paolo / Vallazza, Erik / Afonin, Alexander G / Baranov, Vladimir T / Chesnokov, Yury A / Kotov, Vladilen I / Maisheev, Vladimir A / Yazynin, Igor A / Afanasiev, Sergey V / Kovalenko, Alexander D / Taratin, Alexander M / Bondar, Nikolai F / Denisov, Alexander S / Gavrikov, Yury A / Ivanov, Yuri M / Ivochkin, Vladimir G / Kosyanenko, Sergey V / Lapina, Lyubov P / Levtchenko, Peter M / Petrunin, Anatoli A / Skorobogatov, Vyacheslav V / Suvorov, Vsevolod M / Bolognini, Davide / Foggetta, Luca / Hasan, Said / Prest, Michela

    The Review of scientific instruments

    2008  Volume 79, Issue 2 Pt 1, Page(s) 23303

    Abstract: A high performance apparatus has been designed and built by the H8-RD22 collaboration for the study of channeling and volume reflection phenomena in the interaction of 400 GeV/c protons with bent silicon crystals, during the 2006 data taking in the ... ...

    Abstract A high performance apparatus has been designed and built by the H8-RD22 collaboration for the study of channeling and volume reflection phenomena in the interaction of 400 GeV/c protons with bent silicon crystals, during the 2006 data taking in the external beamline H8 of the CERN SPS. High-quality silicon short crystals were bent by either anticlastic or quasimosaic effects. Alignment with the highly parallel (8 murad divergence) proton beam was guaranteed through a submicroradian goniometric system equipped with both rotational and translational stages. Particle tracking was possible by a series of silicon microstrip detectors with high-resolution and a parallel plate gas chamber, triggered by various scintillating detectors located along the beamline. Experimental observation of volume reflection with 400 GeV/c protons proved true with a deflection angle of (10.4+/-0.5) murad with respect to the unperturbed beam, with a silicon crystal whose (111) planes were parallel to the beam.
    Language English
    Publishing date 2008-02
    Publishing country United States
    Document type Journal Article
    ZDB-ID 209865-9
    ISSN 1089-7623 ; 0034-6748
    ISSN (online) 1089-7623
    ISSN 0034-6748
    DOI 10.1063/1.2832638
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  4. Article: High-efficiency volume reflection of an ultrarelativistic proton beam with a bent silicon crystal.

    Scandale, Walter / Still, Dean A / Carnera, Alberto / Della Mea, Gianantonio / De Salvador, Davide / Milan, Riccardo / Vomiero, Alberto / Baricordi, Stefano / Dalpiaz, Pietro / Fiorini, Massimiliano / Guidi, Vincenzo / Martinelli, Giuliano / Mazzolari, Andrea / Milan, Emiliano / Ambrosi, Giovanni / Azzarello, Philipp / Battiston, Roberto / Bertucci, Bruna / Burger, William J /
    Ionica, Maria / Zuccon, Paolo / Cavoto, Gianluca / Santacesaria, Roberta / Valente, Paolo / Vallazza, Erik / Afonin, Alexander G / Baranov, Vladimir T / Chesnokov, Yury A / Kotov, Vladilen I / Maisheev, Vladimir A / Yaznin, Igor A / Afansiev, Sergey V / Kovalenko, Alexander D / Taratin, Alexander M / Denisov, Alexander S / Gavrikov, Yury A / Ivanov, Yuri M / Ivochkin, Vladimir G / Kosyanenko, Sergey V / Petrunin, Anatoli A / Skorobogatov, Vyacheslav V / Suvorov, Vsevolod M / Bolognini, Davide / Foggetta, Luca / Hasan, Said / Prest, Michela

    Physical review letters

    2007  Volume 98, Issue 15, Page(s) 154801

    Abstract: The volume reflection phenomenon was detected while investigating 400 GeV proton interactions with bent silicon crystals in the external beam H8 of the CERN Super Proton Synchrotron. Such a process was observed for a wide interval of crystal orientations ...

    Abstract The volume reflection phenomenon was detected while investigating 400 GeV proton interactions with bent silicon crystals in the external beam H8 of the CERN Super Proton Synchrotron. Such a process was observed for a wide interval of crystal orientations relative to the beam axis, and its efficiency exceeds 95%, thereby surpassing any previously observed value. These observations suggest new perspectives for the manipulation of high-energy beams, e.g., for collimation and extraction in new-generation hadron colliders, such as the CERN Large Hadron Collider.
    Language English
    Publishing date 2007-04-13
    Publishing country United States
    Document type Journal Article ; Research Support, Non-U.S. Gov't
    ZDB-ID 208853-8
    ISSN 1079-7114 ; 0031-9007
    ISSN (online) 1079-7114
    ISSN 0031-9007
    DOI 10.1103/PhysRevLett.98.154801
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

To top