Artikel ; Online: Aveir VR real-world performance and chronic pacing threshold prediction using mapping and fixation electrical data.
2024 Band 26, Heft 3
Abstract: Aims: Aveir VR performance and predictors for its pacing threshold (PCT) in a real-world cohort were investigated.: Methods: Electrical measurements at various stages of an Aveir VR implant were prospectively collected. Predictors for 3-month PCT ... ...
Abstract | Aims: Aveir VR performance and predictors for its pacing threshold (PCT) in a real-world cohort were investigated. Methods: Electrical measurements at various stages of an Aveir VR implant were prospectively collected. Predictors for 3-month PCT were studied. A retrospective cohort of consecutive 139 Micra implants was used to compare the PCT evolution. High PCT was defined as ≥1.5 V, using a pulse width of 0.4 ms for Aveir and 0.24 ms for Micra. Excellent PCT was defined as ≤0.5 V at the respective pulse width. Results: Among the 123 consecutive Aveir VR implant attempts, 122 (99.2%) were successful. The majority were of advanced age (mean 79.7) and small body size (mean BSA 1.60). Two patients (1.6%) experienced complications, including one pericardial effusion after device reposition and one intraoperative device dislodgement. Eighty-eight patients reached a 3-month follow-up. Aveir 3-month PCT was correlated with impedance at mapping (P = 0.015), tether mode (P < 0.001), end-of-procedure (P < 0.001), and mapping PCT (P = 0.035), but not with PCTs after fixation (P > 0.05). Tether mode impedance >470 ohms had 88% sensitivity and 71% specificity in predicting excellent 3-month PCT. Although it is more common for Aveir to have high PCT at end of procedure (11.5% for Aveir and 2.2% for Micra, P = 0.004), the rate at 3 months was similar (2.3% for Aveir and 3.1% for Micra, P = 1.000). Conclusion: Aveir VR demonstrated satisfactory performance in this high-risk cohort. Pacing thresholds tend to improve to a greater extent than Micra after implantation. The PCT after fixation, even after a waiting period, has limited predictive value for the chronic threshold. Low-mapping PCT and high intraoperative impedance predict chronic low PCT. |
---|---|
Mesh-Begriff(e) | Humans ; Pacemaker, Artificial ; Treatment Outcome ; Retrospective Studies ; Equipment Design ; Virtual Reality ; Cardiac Pacing, Artificial/adverse effects ; Cardiac Pacing, Artificial/methods |
Sprache | Englisch |
Erscheinungsdatum | 2024-03-08 |
Erscheinungsland | England |
Dokumenttyp | Journal Article |
ZDB-ID | 1449879-0 |
ISSN | 1532-2092 ; 1099-5129 |
ISSN (online) | 1532-2092 |
ISSN | 1099-5129 |
DOI | 10.1093/europace/euae051 |
Datenquelle | MEDical Literature Analysis and Retrieval System OnLINE |
Zusatzmaterialien
Kategorien
Verfügbar in ZB MED Köln/Königswinter
Zs.A 5434: Hefte anzeigen | Standort: Je nach Verfügbarkeit (siehe Angabe bei Bestand) bis Jg. 1994: Bestellungen von Artikeln über das Online-Bestellformular Jg. 1995 - 2021: Lesesall (2.OG) ab Jg. 2022: Lesesaal (EG) |
Über subito bestellen
Dieser Service ist kostenpflichtig (siehe Lieferbedingungen von subito). Bestellungen, die einen Artikel nebst Supplementary Material umfassen, werden grundsätzlich wie mehrfache Bestellungen bearbeitet. Gebühren fallen in diesen Fällen für jede einzelne Bestellung an.