LIVIVO - The Search Portal for Life Sciences

zur deutschen Oberfläche wechseln
Advanced search

Search results

Result 1 - 1 of total 1

Search options

Article ; Online: Assessment of normal reference values for thyroid uptake of technetium-99m pertechnetate in a Saudi population

Awad Alshahrani / Gulam M. Syed / Altaf H. Khan / Shah P. Numani / Abdulaziz Alnaim / Faisal Alanazi / Moeber M. Mahzari

Annals of Saudi Medicine, Vol 41, Iss 2, Pp 86-

2021  Volume 90

Abstract: BACKGROUND: Thyrotoxicosis is a common medical problem. Thyroid nuclear imaging with either I123 or technetium-99m (Tc-99m) pertechnetate are used to determine the cause. Although I123 has been the standard technique, Tc-99m pertechnetate is now commonly ...

Abstract BACKGROUND: Thyrotoxicosis is a common medical problem. Thyroid nuclear imaging with either I123 or technetium-99m (Tc-99m) pertechnetate are used to determine the cause. Although I123 has been the standard technique, Tc-99m pertechnetate is now commonly used, acceptable and easier to perform. The commonly used normal value of Tc-99m pertechnetate is 1–4%, but lower normal values have been reported in different populations. OBJECTIVE: Determine normal reference range of Tc-99m pertechne-tate thyroid uptake for thyroid scintigraphy in Saudi Arabia. DESIGN: Retrospective, cross-sectional. SETTING: Nuclear medicine service at tertiary care center in Riyadh. PATIENTS AND METHODS: We used data from biochemically euthyroid patients who underwent a thyroid Tc-99m pertechnetate scan while having parathyroid scintigraphy for hyperparathyroidism between April 2009 to April 2019. Medical records and biochemical thyroid function tests were reviewed and Tc-99m pertechnetate thyroid uptake values were determined for each patient. MAIN OUTCOME MEASURES: Thyroid uptake of Tc-99m pertechne-tate in euthyroid patients. SAMPLE SIZE: 167 RESULTS: The mean and median uptake of Tc-99m pertechnetate in euthyroid patients were 0.86% and 1.0%, respectively, and the inter-quartile range was 0.0–1.0%. The normal reference range in the study population was 0.2-2%. Thyroid uptake inversely correlated with age in females (r=−0.37, P<.001), males (r=−0.46, P=.001), and for all patients (r=−0.39, P<.0001). CONCLUSION: The range for normal thyroid Tc-99m pertechnetate was lower than the standard 1-4% range. Moreover, uptake decreased with age. Further studies are needed to establish the normal age-adjusted uptake for the thyroid Tc-99m pertechnetate scan. LIMITATIONS: Single center and retrospective. CONFLICT OF INTEREST: None.
Keywords Medicine ; R
Subject code 610
Language English
Publishing date 2021-04-01T00:00:00Z
Publisher King Faisal Specialist Hospital and Research Centre
Document type Article ; Online
Database BASE - Bielefeld Academic Search Engine (life sciences selection)

More links

Kategorien

To top