LIVIVO - The Search Portal for Life Sciences

zur deutschen Oberfläche wechseln
Advanced search

Search results

Result 1 - 10 of total 67

Search options

  1. Article ; Online: Evaluation of optimal acquisition delays of DECT iodine maps in pancreatic adenocarcinoma

    Stephan Skornitzke / Philipp Mayer / Hans-Ulrich Kauczor / Wolfram Stiller

    Heliyon, Vol 9, Iss 4, Pp e14726- (2023)

    A potential alternative to the Patlak model of CT perfusion

    2023  

    Abstract: Introduction: By using bolus tracking with an appropriate acquisition delay dual-energy computed tomography (DECT) iodine maps might serve as a replacement of CT perfusion maps at reduced radiation exposure. This study aimed to evaluate the optimal ... ...

    Abstract Introduction: By using bolus tracking with an appropriate acquisition delay dual-energy computed tomography (DECT) iodine maps might serve as a replacement of CT perfusion maps at reduced radiation exposure. This study aimed to evaluate the optimal acquisition delays of DECT for the replacement of parameter maps calculated with the Patlak model in pancreatic adenocarcinoma by corresponding iodine maps. Materials and methods: Dual-source dynamic DECT acquisitions at 80 kVp/Sn140 kVp of 14 patients with pancreatic carcinoma were used to calculate CT perfusion maps of blood volume and permeability with the Patlak model. DECT iodine maps were generated from individual DECT acquisitions, matching acquisition times relative to prior bolus-triggered three-phase CT acquisitions for investigating different acquisition delays. Correlation between perfusion parameters and iodine concentrations was determined for acquisition delays between −6 s and 33 s. Results: Correlation between iodine concentrations and perfusion parameters ranged from −0.05 to 0.63 for blood volume and from −0.05 to 0.71 for permeability, depending on potential trigger delay. The correlation was significant for potential acquisition delays above 1.5 s for blood volume and above 9.0 s for permeability (both p < 0.05). Maximum correlation occurred at an acquisition delay of 15.0 s for blood volume (r = 0.63) and at 25.5 s for permeability (r = 0.71), with significantly lower iodine concentrations in carcinoma (15.0 s: 1.3 ± 0.5 mg/ml; 22.5 s: 1.4 ± 0.7 mg/ml) than in non-neoplastic pancreatic parenchyma (15.0 s: 2.3 ± 0.8 mg/ml; 22.5 s: 2.4 ± 0.6 mg/ml; p < 0.05). Discussion: In the future, well-timed DECT iodine maps acquired with bolus tracking could provide an alternative to permeability and blood volume maps calculated with the Patlak model.
    Keywords CT perfusion ; Dual-energy CT ; Iodine quantification ; Pancreatic carcinoma ; Science (General) ; Q1-390 ; Social sciences (General) ; H1-99
    Subject code 610
    Language English
    Publishing date 2023-04-01T00:00:00Z
    Publisher Elsevier
    Document type Article ; Online
    Database BASE - Bielefeld Academic Search Engine (life sciences selection)

    More links

    Kategorien

  2. Article ; Online: Jointly Optimized Deep Neural Networks to Synthesize Monoenergetic Images from Single-Energy CT Angiography for Improving Classification of Pulmonary Embolism

    Matthias A. Fink / Constantin Seibold / Hans-Ulrich Kauczor / Rainer Stiefelhagen / Jens Kleesiek

    Diagnostics, Vol 12, Iss 1224, p

    2022  Volume 1224

    Abstract: Detector-based spectral CT offers the possibility of obtaining spectral information from which discrete acquisitions at different energy levels can be derived, yielding so-called virtual monoenergetic images (VMI). In this study, we aimed to develop a ... ...

    Abstract Detector-based spectral CT offers the possibility of obtaining spectral information from which discrete acquisitions at different energy levels can be derived, yielding so-called virtual monoenergetic images (VMI). In this study, we aimed to develop a jointly optimized deep-learning framework based on dual-energy CT pulmonary angiography (DE-CTPA) data to generate synthetic monoenergetic images (SMI) for improving automatic pulmonary embolism (PE) detection in single-energy CTPA scans. For this purpose, we used two datasets: our institutional DE-CTPA dataset <math xmlns="http://www.w3.org/1998/Math/MathML" display="inline"><semantics><msub><mi>D</mi><mn>1</mn></msub></semantics></math> , comprising polyenergetic arterial series and the corresponding VMI at low-energy levels (40 keV) with 7892 image pairs, and a 10% subset of the 2020 RSNA Pulmonary Embolism CT Dataset <math xmlns="http://www.w3.org/1998/Math/MathML" display="inline"><semantics><msub><mi>D</mi><mn>2</mn></msub></semantics></math> , which consisted of 161,253 polyenergetic images with dichotomous slice-wise annotations (PE/no PE). We trained a fully convolutional encoder-decoder on <math xmlns="http://www.w3.org/1998/Math/MathML" display="inline"><semantics><msub><mi>D</mi><mn>1</mn></msub></semantics></math> to generate SMI from single-energy CTPA scans of <math xmlns="http://www.w3.org/1998/Math/MathML" display="inline"><semantics><msub><mi>D</mi><mn>2</mn></msub></semantics></math> , which were then fed into a ResNet50 network for training of the downstream PE classification task. The quantitative results on the reconstruction ability of our framework revealed high-quality visual SMI predictions with reconstruction results of 0.984 ± 0.002 (structural similarity) and 41.706 ± 0.547 dB (peak signal-to-noise ...
    Keywords artificial intelligence ; deep learning ; image-to-image translation ; dual-energy computed tomography ; pulmonary embolism ; emergency radiology ; Medicine (General) ; R5-920
    Subject code 006
    Language English
    Publishing date 2022-05-01T00:00:00Z
    Publisher MDPI AG
    Document type Article ; Online
    Database BASE - Bielefeld Academic Search Engine (life sciences selection)

    More links

    Kategorien

  3. Article ; Online: 3-Tesla T2 Mapping Magnetic Resonance Imaging for Evaluation of SLAP Lesions in Patients with Shoulder Pain

    Patrick Stein / Felix Wuennemann / Thomas Schneider / Felix Zeifang / Iris Burkholder / Marc-André Weber / Hans-Ulrich Kauczor / Christoph Rehnitz

    Journal of Clinical Medicine, Vol 12, Iss 3109, p

    An Arthroscopy-Controlled Study

    2023  Volume 3109

    Abstract: This study investigated the ability of T2 mapping to assess the glenoid labrum and to differentiate between healthy labral substances and superior labral anterior posterior (SLAP) lesions using arthroscopy as the gold standard. Eighteen patients (mean ... ...

    Abstract This study investigated the ability of T2 mapping to assess the glenoid labrum and to differentiate between healthy labral substances and superior labral anterior posterior (SLAP) lesions using arthroscopy as the gold standard. Eighteen patients (mean age: 52.4 ± 14.72 years, 12 men) with shoulder pain were examined using 3-Tesla T2 mapping. All the patients underwent shoulder arthroscopy. Using morphological sequences for correlation, regions of interest covering the entire labral substance were placed in the corresponding T2 maps. The diagnostic cutoff values, sensitivities, and specificities, as well as the inter-reader correlation coefficients (ICCs) determined by two independent radiologists, were calculated. The mean T2 value was 20.8 ± 2.4 ms for the healthy labral substances and 37.7 ± 10.63 ms in the patients with SLAP lesions. The maximum T2 value in normal labrum (21.2 ms) was lower than the minimum T2 value in the patients with SLAP lesions (27.8 ms), leading to sensitivities, specificities, and positive and negative predictive values of 100% (95% CI 54.1–100.0) for all the cutoff values between 21.2 and 27.8 ms. The ICCs ranged from 0.91 to 0.99. In summary, the data suggest that evaluation and quantification of the labral (ultra)structural integrity using T2 mapping may allow discrimination between arthroscopically confirmed SLAP lesions and a healthy glenoid labrum. T2 mapping may therefore be helpful in diagnosing patients with suspected labral damage.
    Keywords T2 mapping ; glenoid labrum ; superior labral anterior posterior (SLAP) lesions ; arthroscopy ; Medicine ; R
    Subject code 610
    Language English
    Publishing date 2023-04-01T00:00:00Z
    Publisher MDPI AG
    Document type Article ; Online
    Database BASE - Bielefeld Academic Search Engine (life sciences selection)

    More links

    Kategorien

  4. Article ; Online: Evaluation and timing optimization of CT perfusion first pass analysis in comparison to maximum slope model in pancreatic adenocarcinoma

    Neha Vats / Philipp Mayer / Franziska Kortes / Miriam Klauß / Lars Grenacher / Wolfram Stiller / Hans-Ulrich Kauczor / Stephan Skornitzke

    Scientific Reports, Vol 13, Iss 1, Pp 1-

    2023  Volume 11

    Abstract: Abstract For implementation, performance evaluation and timing optimization of CT perfusion first pass analysis (FPA) by correlation with maximum slope model (MSM) in pancreatic adenocarcinoma, dynamic CT perfusion acquisitions of 34 time-points were ... ...

    Abstract Abstract For implementation, performance evaluation and timing optimization of CT perfusion first pass analysis (FPA) by correlation with maximum slope model (MSM) in pancreatic adenocarcinoma, dynamic CT perfusion acquisitions of 34 time-points were performed in 16 pancreatic adenocarcinoma patients. Regions of interest were marked in both parenchyma and carcinoma. FPA, a low radiation exposure CT perfusion technique, was implemented. Blood flow (BF) perfusion maps were calculated using FPA and MSM. Pearson’s correlation between FPA and MSM was calculated at each evaluated time-point to determine optimum timing for FPA. Differences in BF between parenchyma and carcinoma were calculated. Average BF for MSM was 106.8 ± 41.5 ml/100 ml/min in parenchyma and 42.0 ± 24.8 ml/100 ml/min in carcinoma, respectively. For FPA, values ranged from 85.6 ± 37.5 ml/100 ml/min to 117.7 ± 44.5 ml/100 ml/min in parenchyma and from 27.3 ± 18.8 ml/100 ml/min to 39.5 ± 26.6 ml/100 ml/min in carcinoma, depending on acquisition timing. A significant difference (p value < 0.0001) between carcinoma and parenchyma was observed at all acquisition times based on FPA measurements. FPA shows high correlation with MSM (r > 0.90) and 94% reduction in the radiation dose compared to MSM. CT perfusion FPA, where the first scan is obtained after the arterial input function exceeds a threshold of 120 HU, followed by a second scan after 15.5–20.0 s, could be used as a potential imaging biomarker with low radiation exposure for diagnosing and evaluating pancreatic carcinoma in clinical practice, showing high correlation with MSM and the ability to differentiate between parenchyma and carcinoma.
    Keywords Medicine ; R ; Science ; Q
    Subject code 610
    Language English
    Publishing date 2023-06-01T00:00:00Z
    Publisher Nature Portfolio
    Document type Article ; Online
    Database BASE - Bielefeld Academic Search Engine (life sciences selection)

    More links

    Kategorien

  5. Article ; Online: Prospective Study of Low-Radiation and Low-Iodine Dose Aortic CT Angiography in Obese and Non-Obese Patients

    Matthias A. Fink / Sibylle Stoll / Claudius Melzig / Andrea Steuwe / Sasan Partovi / Dittmar Böckler / Hans-Ulrich Kauczor / Fabian Rengier

    Diagnostics, Vol 12, Iss 675, p

    Image Quality and Impact of Patient Characteristics

    2022  Volume 675

    Abstract: The purpose of this study was to prospectively analyse image quality and radiation dose of body mass index (BMI)-adapted low-radiation and low-iodine dose CTA of the thoracoabdominal aorta in obese and non-obese patients. This prospective, single-centre ... ...

    Abstract The purpose of this study was to prospectively analyse image quality and radiation dose of body mass index (BMI)-adapted low-radiation and low-iodine dose CTA of the thoracoabdominal aorta in obese and non-obese patients. This prospective, single-centre study included patients scheduled for aortic CTA between November 2017 and August 2020 without symptoms of high-grade heart failure. A BMI-adapted protocol was used: Group A/Group B, BMI < 30/≥ 30 kg/m 2 , tube potential 80/100 kVp, total iodine dose 14.5/17.4 g. Intraindividual comparison with the institutional clinical routine aortic CTA protocol was performed. The final study cohort comprised 161 patients (mean 71.1 ± 9.4 years, 32 women), thereof 126 patients in Group A (mean BMI 25.4 ± 2.8 kg/m 2 ) and 35 patients in Group B (34.0 ± 3.4 kg/m 2 ). Mean attenuation over five aortoiliac measurement positions for Group A/B was 354.9 ± 78.2/262.1 ± 73.0 HU. Mean effective dose for Group A/B was 3.05 ± 0.46/6.02 ± 1.14 mSv. Intraindividual comparison in 50 patients demonstrated effective dose savings for Group A/B of 34.4 ± 14.5/25.4 ± 14.1% (both p < 0.001), and iodine dose savings for Group A/B of 54/44.8%. Regression analysis showed that female sex and increasing age were independently associated with higher vascular attenuation. In conclusion, BMI-adapted, low-radiation and low-iodine dose CTA of the thoracoabdominal aorta delivers diagnostic image quality in non-obese and obese patients without symptoms of high-grade heart failure, with superior image quality in females and the elderly.
    Keywords aorta ; computed tomography angiography ; radiation dosage ; contrast media ; obesity ; Medicine (General) ; R5-920
    Subject code 616 ; 610
    Language English
    Publishing date 2022-03-01T00:00:00Z
    Publisher MDPI AG
    Document type Article ; Online
    Database BASE - Bielefeld Academic Search Engine (life sciences selection)

    More links

    Kategorien

  6. Article ; Online: Echo time-dependent observed T1 and quantitative perfusion in chronic obstructive pulmonary disease using magnetic resonance imaging

    Simon M. F. Triphan / Marilisa Konietzke / Jürgen Biederer / Monika Eichinger / Claus F. Vogelmeier / Rudolf A. Jörres / Hans-Ulrich Kauczor / Claus P. Heußel / Bertram J. Jobst / Mark O. Wielpütz / on behalf of the COSYCONET study group

    Frontiers in Medicine, Vol

    2024  Volume 10

    Abstract: IntroductionDue to hypoxic vasoconstriction, perfusion is interesting in the lungs. Magnetic Resonance Imaging (MRI) perfusion imaging based on Dynamic Contrast Enhancement (DCE) has been demonstrated in patients with Chronic Obstructive Pulmonary ... ...

    Abstract IntroductionDue to hypoxic vasoconstriction, perfusion is interesting in the lungs. Magnetic Resonance Imaging (MRI) perfusion imaging based on Dynamic Contrast Enhancement (DCE) has been demonstrated in patients with Chronic Obstructive Pulmonary Diseases (COPD) using visual scores, and quantification methods were recently developed further. Inter-patient correlations of echo time-dependent observed T1 [T1(TE)] have been shown with perfusion scores, pulmonary function testing, and quantitative computed tomography. Here, we examined T1(TE) quantification and quantitative perfusion MRI together and investigated both inter-patient and local correlations between T1(TE) and quantitative perfusion.Methods22 patients (age 68.0 ± 6.2) with COPD were examined using morphological MRI, inversion recovery multi-echo 2D ultra-short TE (UTE) in 1–2 slices for T1(TE) mapping, and 4D Time-resolved angiography With Stochastic Trajectories (TWIST) for DCE. T1(TE) maps were calculated from 2D UTE at five TEs from 70 to 2,300 μs. Pulmonary Blood Flow (PBF) and perfusion defect (QDP) maps were produced from DCE measurements. Lungs were automatically segmented on UTE images and morphological MRI and these segmentations registered to DCE images. DCE images were separately registered to UTE in corresponding slices and divided into corresponding subdivisions. Spearman’s correlation coefficients were calculated for inter-patient correlations using the entire segmented slices and for local correlations separately using registered images and subdivisions for each TE. Median T1(TE) in normal and defect areas according to QDP maps were compared.ResultsInter-patient correlations were strongest on average at TE2 = 500 μs, reaching up to |ρ| = 0.64 for T1 with PBF and |ρ| = 0.76 with QDP. Generally, local correlations of T1 with PBF were weaker at TE2 than at TE1 or TE3 and with maximum values of |ρ| = 0.66 (from registration) and |ρ| = 0.69 (from subdivision). In 18 patients, T1 was shorter in defect areas than in normal areas, with the ...
    Keywords magnetic resonance imaging ; functional lung imaging ; T1 mapping ; lung T1 ; chronic obstructive pulmonary disease ; dynamic contrast enhancement ; Medicine (General) ; R5-920
    Subject code 610
    Language English
    Publishing date 2024-01-01T00:00:00Z
    Publisher Frontiers Media S.A.
    Document type Article ; Online
    Database BASE - Bielefeld Academic Search Engine (life sciences selection)

    More links

    Kategorien

  7. Article ; Online: Developing a lung nodule management protocol specifically for cardiac CT

    Robert Haase / Jonathan D. Dodd / Hans-Ulrich Kauczor / Ella A. Kazerooni / Marc Dewey

    European Journal of Radiology Open, Vol 7, Iss , Pp 100235- (2020)

    Methodology in the DISCHARGE trial

    2020  

    Abstract: Purpose: In this methodology paper we describe the development of a lung nodule management algorithm specifically for patients undergoing cardiac CT. Methods: We modified the Lung-RADS algorithm specifically to manage lung nodules incidentally detected ... ...

    Abstract Purpose: In this methodology paper we describe the development of a lung nodule management algorithm specifically for patients undergoing cardiac CT. Methods: We modified the Lung-RADS algorithm specifically to manage lung nodules incidentally detected on cardiac CT (Lung-RADS for cardiac CT). We will evaluate the modified algorithm as part of the DISCHARGE trial (www.dischargetrial.eu) in which patients with suspected coronary artery disease are randomly assigned to cardiac CT or invasive coronary angiography across Europe at 16 sites involving 3546 patients. Patients will be followed for up to four years. Results: The major adjustments to Lung-RADS specifically for cardiac CT relate to 1) incomplete coverage of the lungs by cardiac CT compared with chest CT, and when to order a completion chest CT versus a follow up chest CT, 2) cardiac CT findings will not trigger annual lung-cancer screening, and 3) a lower threshold of at least 10 mm for classifying new ground glass nodules as probably benign (category 3). Conclusions: The DISCHARGE trial will assess a lung nodule management algorithm designed specifically for cardiac CT in patients with stable chest pain across Europe.
    Keywords Adult ; Computed tomography angiography* ; Incidental findings* ; Lung/diagnostic imaging ; Medical physics. Medical radiology. Nuclear medicine ; R895-920
    Subject code 610
    Language English
    Publishing date 2020-01-01T00:00:00Z
    Publisher Elsevier
    Document type Article ; Online
    Database BASE - Bielefeld Academic Search Engine (life sciences selection)

    More links

    Kategorien

  8. Article ; Online: Simultaneous assessment of heart and lungs with gated high-pitch ultra-low dose chest CT using artificial intelligence-based calcium scoring

    Florian Andre / Sebastian Seitz / Philipp Fortner / Thomas Allmendinger / André Sommer / Matthias Brado / Roman Sokiranski / Joana Fink / Hans-Ulrich Kauczor / Claus P. Heussel / Felix Herth / Norbert Frey / Johannes Görich / Sebastian J. Buss

    European Journal of Radiology Open, Vol 10, Iss , Pp 100481- (2023)

    2023  

    Abstract: Purpose: The combined testing for coronary artery and pulmonary diseases is of clinical interest as risk factors are shared. In this study, a novel ECG-gated tin-filtered ultra-low dose chest CT protocol (GCCT) for integrated heart and lung acquisition ... ...

    Abstract Purpose: The combined testing for coronary artery and pulmonary diseases is of clinical interest as risk factors are shared. In this study, a novel ECG-gated tin-filtered ultra-low dose chest CT protocol (GCCT) for integrated heart and lung acquisition and the applicability of artificial intelligence (AI)-based coronary artery calcium scoring were assessed. Methods: In a clinical registry of 10481 patients undergoing heart and lung CT, GCCT was applied in 44 patients on a dual-source CT. Coronary calcium scans (CCS) with 120 kVp, 100 kVp, and tin-filtered 100 kVp (Sn100) of controls, matched with regard to age, sex, and body-mass index, were retrieved from the registry (ntotal=176, 66.5 (59.4–74.0) years, 52 men). Automatic tube current modulation was used in all scans. In 20 patients undergoing GCCT and Sn100 CCS, Agatston scores were measured both semi-automatically by experts and by AI, and classified into six groups (0, <10, <100, <400, <1000, ≥1000). Results: Effective dose decreased significantly from 120 kVp CCS (0.50 (0.41–0.61) mSv) to 100 kVp CCS (0.34 (0.26–0.37) mSv) to Sn100 CCS (0.14 (0.11–0.17) mSv). GCCT showed higher values (0.28 (0.21–0.32) mSv) than Sn100 CCS but lower than 120 kVp and 100 kVp CCS (all p < 0.05) despite greater scan length. Agatston scores correlated strongly between GCCT and Sn100 CCS in semi-automatic and AI-based measurements (both ρ = 0.98, p < 0.001) resulting in high agreement in Agatston score classification (κ = 0.97, 95% CI 0.92–1.00; κ = 0.89, 95% CI 0.79–0.99). Regarding chest findings, further diagnostic steps were recommended in 28 patients. Conclusions: GCCT allows for reliable coronary artery disease and lung cancer screening with ultra-low radiation exposure. GCCT-derived Agatston score shows excellent agreement with standard CCS, resulting in equivalent risk stratification.
    Keywords Coronary artery disease ; Coronary artery calcium scoring ; Chest CT ; Tin-filter ; Dose reduction ; Artificial intelligence ; Medical physics. Medical radiology. Nuclear medicine ; R895-920
    Subject code 610
    Language English
    Publishing date 2023-01-01T00:00:00Z
    Publisher Elsevier
    Document type Article ; Online
    Database BASE - Bielefeld Academic Search Engine (life sciences selection)

    More links

    Kategorien

  9. Article ; Online: GOLD stage-specific phenotyping of emphysema and airway disease using quantitative computed tomography

    Philip Konietzke / Christian Brunner / Marilisa Konietzke / Willi Linus Wagner / Oliver Weinheimer / Claus Peter Heußel / Felix J. F. Herth / Franziska Trudzinski / Hans-Ulrich Kauczor / Mark Oliver Wielpütz

    Frontiers in Medicine, Vol

    2023  Volume 10

    Abstract: BackgroundIn chronic obstructive pulmonary disease (COPD) abnormal lung function is related to emphysema and airway obstruction, but their relative contribution in each GOLD-stage is not fully understood. In this study, we used quantitative computed ... ...

    Abstract BackgroundIn chronic obstructive pulmonary disease (COPD) abnormal lung function is related to emphysema and airway obstruction, but their relative contribution in each GOLD-stage is not fully understood. In this study, we used quantitative computed tomography (QCT) parameters for phenotyping of emphysema and airway abnormalities, and to investigate the relative contribution of QCT emphysema and airway parameters to airflow limitation specifically in each GOLD stage.MethodsNon-contrast computed tomography (CT) of 492 patients with COPD former GOLD 0 COPD and COPD stages GOLD 1–4 were evaluated using fully automated software for quantitative CT. Total lung volume (TLV), emphysema index (EI), mean lung density (MLD), and airway wall thickness (WT), total diameter (TD), lumen area (LA), and wall percentage (WP) were calculated for the entire lung, as well as for all lung lobes separately. Results from the 3rd-8th airway generation were aggregated (WT3-8, TD3-8, LA3-8, WP3-8). All subjects underwent whole-body plethysmography (FEV1%pred, VC, RV, TLC).ResultsEI was higher with increasing GOLD stages with 1.0 ± 1.8% in GOLD 0, 4.5 ± 9.9% in GOLD 1, 19.4 ± 15.8% in GOLD 2, 32.7 ± 13.4% in GOLD 3 and 41.4 ± 10.0% in GOLD 4 subjects (p < 0.001). WP3-8 showed no essential differences between GOLD 0 and GOLD 1, tended to be higher in GOLD 2 with 52.4 ± 7.2%, and was lower in GOLD 4 with 50.6 ± 5.9% (p = 0.010 – p = 0.960). In the upper lobes WP3–8 showed no significant differences between the GOLD stages (p = 0.824), while in the lower lobes the lowest WP3-8 was found in GOLD 0/1 with 49.9 ± 6.5%, while higher values were detected in GOLD 2 with 51.9 ± 6.4% and in GOLD 3/4 with 51.0 ± 6.0% (p < 0.05). In a multilinear regression analysis, the dependent variable FEV1%pred can be predicted by a combination of both the independent variables EI (p < 0.001) and WP3–8 (p < 0.001).ConclusionQCT parameters showed a significant increase of emphysema from GOLD 0–4 COPD. Airway changes showed a different spatial pattern ...
    Keywords chronic obstructive pulmonary disease (COPD) ; quantitative CT (QCT) ; GOLD stages ; airway disease ; lung emphysema ; Medicine (General) ; R5-920
    Subject code 540
    Language English
    Publishing date 2023-07-01T00:00:00Z
    Publisher Frontiers Media S.A.
    Document type Article ; Online
    Database BASE - Bielefeld Academic Search Engine (life sciences selection)

    More links

    Kategorien

  10. Article ; Online: Experimental application of an automated alignment correction algorithm for geological CT imaging

    Stephan Skornitzke / Jacek Raddatz / André Bahr / Gregor Pahn / Hans-Ulrich Kauczor / Wolfram Stiller

    European Radiology Experimental, Vol 3, Iss 1, Pp 1-

    phantom study and application to sediment cores from cold-water coral mounds

    2019  Volume 8

    Abstract: Abstract Background In computed tomography (CT) quality assurance, alignment of image quality phantoms is crucial for quantitative and reproducible evaluation and may be improved by alignment correction. Our goal was to develop an alignment correction ... ...

    Abstract Abstract Background In computed tomography (CT) quality assurance, alignment of image quality phantoms is crucial for quantitative and reproducible evaluation and may be improved by alignment correction. Our goal was to develop an alignment correction algorithm to facilitate geological sampling of sediment cores taken from a cold-water coral mount. Methods An alignment correction algorithm was developed and tested with a CT acquisition at 120 kVp and 150 mAs of an image quality phantom. Random translation (maximum 15 mm) and rotation (maximum 2.86°) were applied and ground-truth was compared to parameters determined by alignment correction. Furthermore, mean densities were evaluated in four regions of interest (ROIs) placed in the phantom low-contrast section, comparing values before and after correction to ground truth. This process was repeated 1000 times. After validation, alignment correction was applied to CT acquisitions (140 kVp, 570 mAs) of sediment core sections up to 1 m in length, and sagittal reconstructions were calculated for sampling planning. Results In the phantom, average absolute differences between applied and detected parameters after alignment correction were 0.01 ± 0.06 mm (mean ± standard deviation) along the x-axis, 0.11 ± 0.08 mm along the y-axis, 0.15 ± 0.07° around the x-axis, and 0.02 ± 0.02° around the y-axis, respectively. For ROI analysis, differences in densities were 63.12 ± 30.57, 31.38 ± 32.10, 18.27 ± 35.57, and 9.59 ± 26.37 HU before alignment correction and 1.22 ± 1.40, 0.76 ± 0.9, 0.45 ± 0.86, and 0.36 ± 0.48 HU after alignment correction, respectively. For sediment core segments, average absolute detected parameters were 3.93 ± 2.89 mm, 7.21 ± 2.37 mm, 0.37 ± 0.33°, and 0.21 ± 0.22°, respectively. Conclusions The alignment correction algorithm was successfully evaluated in the phantom and allowed a correct alignment of sediment core segments, thus aiding in sampling planning. Application to other tasks, like image quality analysis, seems possible.
    Keywords Alignment correction ; Cold-water corals ; Phantoms (imaging) ; Sediment core ; Tomography (x-ray computed) ; Medical physics. Medical radiology. Nuclear medicine ; R895-920
    Subject code 550
    Language English
    Publishing date 2019-03-01T00:00:00Z
    Publisher SpringerOpen
    Document type Article ; Online
    Database BASE - Bielefeld Academic Search Engine (life sciences selection)

    More links

    Kategorien

To top