LIVIVO - The Search Portal for Life Sciences

zur deutschen Oberfläche wechseln
Advanced search

Search results

Result 1 - 10 of total 35

Search options

  1. Article ; Online: Five-year outcomes for bell bottom, iliac branch endoprosthesis, and coil and cover approaches from the GREAT registry.

    Giese, Angela / Heyligers, Jan M M / Milner, Ross

    Journal of vascular surgery

    2024  

    Abstract: Objective: There are a variety of methods used today to treat common iliac aneurysms with endovascular techniques. Of these approaches, little is known about whether a particular limb strategy influences endoleak, reintervention, or aneurysm regression ... ...

    Abstract Objective: There are a variety of methods used today to treat common iliac aneurysms with endovascular techniques. Of these approaches, little is known about whether a particular limb strategy influences endoleak, reintervention, or aneurysm regression rates. We present 5-year data comparing endoleak, stent graft migration, fracture, aneurysm sac dynamics, and aortic rupture rates among patients treated with bell bottom limbs (BB), iliac branch endoprosthesis (IBE), and coil and cover (CC) approaches from the Global Registry for Endovascular Aortic Treatment registry. Secondary end points were all-cause mortality, stroke, reintervention, and paraplegia.
    Methods: Subjects from the GORE Global Registry for Endovascular Aortic Treatment were enrolled over a 5-year period from October 2017 to August 2022. We included 924 subjects in this study. Statistical data was generated on R software and limb groups were compared using the Pearson's χ
    Results: We found no statistical difference in endoleak rates, stent graft migration, fracture, or aortic rupture when stratified by limb strategy. There was no difference between limb approaches with regard to aneurysm sac dynamics among those with abdominal aortic aneurysms and common iliac aneurysms. Similarly, no statistical difference between limb strategies was found in all-cause mortality, stroke, paraplegia, or reintervention rates. Among patients that required an additional graft during reintervention, the highest rates were found within the IBE group 8.6%, compared with BB group 2.2% and CC group 1.3% (P = .006).
    Conclusions: Overall, there was no difference among limb strategies in endoleak rates, stent graft migration, aneurysm sac dynamics, aortic rupture rates, or our secondary end points. Increased rates of reintervention requiring an additional graft within the IBE group is noteworthy and must be weighed against the adverse effects of hypogastric sacrifice with the CC approach or potentially less advantageous seal zones in the BB approach. This finding suggests that all limb approaches have equivalent effectiveness in managing the aneurysmal common iliac artery; thus, the choice of limb strategy should be individualized and remain at physician discretion. Future research should include a more robust sample size to reproduce these findings.
    Language English
    Publishing date 2024-02-03
    Publishing country United States
    Document type Journal Article
    ZDB-ID 605700-7
    ISSN 1097-6809 ; 0741-5214
    ISSN (online) 1097-6809
    ISSN 0741-5214
    DOI 10.1016/j.jvs.2024.01.212
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  2. Article ; Online: Long Term Outcomes of the Gore Excluder Low Permeability Endoprosthesis for the Treatment of Infrarenal Aortic Aneurysms.

    Smorenburg, Stefan P M / de Bruin, Jorg L / Zeebregts, Clark J / Reijnen, Michel M P J / Verhagen, Hence J M / Heyligers, Jan M M

    European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery

    2024  

    Abstract: Objective: This study evaluated the long term outcomes of endovascular aneurysm repair using the Gore Excluder Low Permeability (LP) endoprosthesis across high volume Dutch hospitals.: Methods: A retrospective analysis was conducted of patients ... ...

    Abstract Objective: This study evaluated the long term outcomes of endovascular aneurysm repair using the Gore Excluder Low Permeability (LP) endoprosthesis across high volume Dutch hospitals.
    Methods: A retrospective analysis was conducted of patients treated with the Excluder LP for infrarenal abdominal aortic aneurysm (AAA) in four hospitals between 2004 and 2017. Primary outcomes were overall survival, freedom from re-interventions (overall, inside and outside instructions for use, IFU), and AAA sac dynamics: growth (> 5 mm), stabilisation, and regression (< 5 mm). Secondary outcomes were technical success (device deployment), procedural parameters, and re-interventions. Follow up visits were extracted from patient files, with imaging assessed for complications and AAA diameter.
    Results: Five hundred and fourteen patients were enrolled, with a median (IQR) follow up of 5.0 (2.9, 6.9) years. Survival rates were 94.0% at one year, 73.0% at five years, and 37.0% at 10 years, with freedom from re-interventions of 89.0%, 79.0%, and 71.0%, respectively. 37.9% were treated outside IFU, leading to significantly more re-interventions over 10 years compared with those treated inside IFU (36.0% vs. 25.0%, respectively; p = .044). The aneurysm sac regressed by 53.5% at one year, 65.8% at five years, and 77.8% at 10 years, and grew by 9.8%, 14.3%, and 22.2%, respectively. Patients with one year sac growth had significantly worse survival (p = .047). Seven patients (1.4%) had a ruptured aneurysm during follow up. Over 15 years, type 1a endoleak occurred in 5.3%, type 1b in 3.1%, type 3 in 1.9%, type 4 in 0.2%, and type 2 in 35.6% of patients.
    Conclusion: This multicentre study of real world endovascular aneurysm repair data using the Gore Excluder LP endoprosthesis demonstrated robust long term survival and re-intervention rates, despite 37.9% of patients being treated outside IFU, with type 4 endoleak being rare. Treatment outside IFU significantly increased re-intervention rates and one year sac growth was associated with statistically significantly worse survival.
    Language English
    Publishing date 2024-03-26
    Publishing country England
    Document type Journal Article
    ZDB-ID 1225869-6
    ISSN 1532-2165 ; 1078-5884
    ISSN (online) 1532-2165
    ISSN 1078-5884
    DOI 10.1016/j.ejvs.2024.03.028
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  3. Article ; Online: One-year follow-up after active aortic aneurysm sac treatment with shape memory polymer devices during endovascular aneurysm repair.

    Holden, Andrew / Hill, Andrew A / Khashram, Manar / Heyligers, Jan M M / Wiersema, Arno M / Hayes, Paul D / Reijnen, Michel M P J

    Journal of vascular surgery

    2024  Volume 79, Issue 5, Page(s) 1090–1100.e4

    Abstract: Objective: To determine the safety and efficacy of treating abdominal aortic aneurysm (AAA) sacs with polyurethane shape memory polymer (SMP) devices during endovascular aneurysm repair (EVAR), using a technique to fully treat the target lumen after ... ...

    Abstract Objective: To determine the safety and efficacy of treating abdominal aortic aneurysm (AAA) sacs with polyurethane shape memory polymer (SMP) devices during endovascular aneurysm repair (EVAR), using a technique to fully treat the target lumen after endograft placement (aortic flow volume minus the endograft volume). SMP devices self-expand in the sac to form a porous scaffold that supports thrombosis throughout its structure.
    Methods: Two identical prospective, multicenter, single-arm studies were conducted in New Zealand and the Netherlands. The study population was adult candidates for elective EVAR of an infrarenal AAA (diameter of ≥55 mm in men and ≥50 mm in women). Key exclusion criteria were an inability to adequately seal a common iliac artery aneurysm, patent sac feeding vessels of >4 mm, and a target lumen volume of <20 mL or >135 mL. Target lumen volumes were estimated by subtracting endograft volumes from preprocedural imaging-based flow lumen volumes. SMP devices were delivered immediately after endograft deployment via a 6F sheath jailed in a bowed position in the sac. The primary efficacy end point was technical success, defined as filling the actual target lumen volume with fully expanded SMP at the completion of the procedure. Secondary efficacy outcome measures during follow-up were the change in sac volume and diameter, rate of type II endoleak and type I or III endoleaks, and the rate of open repair and related reinterventions, with data collection at 30 days, 6 months, and 1 year (to date). Baseline sac volumes and diameters for change in sac size analyses were determined from 30-day imaging studies. Baseline and follow-up volumes were normalized by subtraction of the endograft volume.
    Results: Of 34 patients treated with SMP devices and followed per protocol, 33 patients were evaluable at 1 year. Preprocedural aneurysm volume was 181.4 mL (95% confidence interval [CI], 150.7-212.1 mL) and preprocedural aneurysm diameter was 60.8 mm (95% CI, 57.8-63.9 mm). The target lumen volume was 56.3 mL (95% CI, 46.9-65.8 mL). Technical success was 100% and the ratio of SMP fully expanded volume to estimated target lumen volume was 1.4 ± 0.3. Baseline normalized sac volume and diameter were 140.7 mL (95% CI, 126.6-154.9 mL) and 61.0 mm (95% CI, 59.7-62.3 mm). The adjusted mean percentage change in normalized volume at 1 year was -28.8% (95% CI, -35.3 to -22.3%; P < .001). The adjusted mean change in sac diameter at 1 year was -5.9 mm (95% CI, -7.5 to -4.4 mm; P < .001). At 1 year, 81.8% of patients (95% CI, 64.5%-93.0%) achieved a ≥10% decrease in normalized volume and 57.6% of patients (95% CI, 39.2%-74.5%) achieved a ≥5 mm decrease in diameter. No device- or study procedure-related major adverse events occurred through 1 year after the procedure.
    Conclusions: Treatment of AAA sacs with SMP devices during EVAR resulted in significant sac volume and diameter regression at 1 year with an acceptable safety profile in this prospective study.
    MeSH term(s) Male ; Humans ; Female ; Blood Vessel Prosthesis ; Aortic Aneurysm, Abdominal/diagnostic imaging ; Aortic Aneurysm, Abdominal/surgery ; Aortic Aneurysm, Abdominal/etiology ; Prospective Studies ; Blood Vessel Prosthesis Implantation/adverse effects ; Endovascular Aneurysm Repair ; Follow-Up Studies ; Treatment Outcome ; Endovascular Procedures/adverse effects ; Retrospective Studies ; Endoleak/diagnostic imaging ; Endoleak/etiology ; Endoleak/surgery ; Risk Factors
    Language English
    Publishing date 2024-01-05
    Publishing country United States
    Document type Multicenter Study ; Journal Article
    ZDB-ID 605700-7
    ISSN 1097-6809 ; 0741-5214
    ISSN (online) 1097-6809
    ISSN 0741-5214
    DOI 10.1016/j.jvs.2023.12.045
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  4. Article: Brown-Séquard Syndrome after Thoracic Endovascular Aortic Repair for a Stanford Type B Aortic Dissection.

    Klijn, Adine J / Heida, Jennie / Burger, Desiree H C / Heyligers, Jan M M / Pouwels, Sjaak

    Vascular specialist international

    2022  Volume 38, Page(s) 12

    Abstract: We present a case of Brown-Séquard syndrome (BSS) after thoracic endovascular aortic repair (TEVAR) to treat Stanford type B aortic dissection. A 49-year-old male presented to the emergency department with acute tearing pain between the scapulae, ... ...

    Abstract We present a case of Brown-Séquard syndrome (BSS) after thoracic endovascular aortic repair (TEVAR) to treat Stanford type B aortic dissection. A 49-year-old male presented to the emergency department with acute tearing pain between the scapulae, connected to respiratory movements. Computed tomography showed Stanford type B aortic dissection from the left subclavian artery to the level of the 11th thoracic vertebra. Conservative treatment was initiated with intravenous antihypertensives. However, due to persistent pain and an increase in the aortic diameter with an intramural hematoma, TEVAR was performed. The patient developed symptoms suspicious of spinal cord ischemia postoperatively. A lesion limited to the left-sided spinal cord was observed on magnetic resonance imaging at the level of the 4th to 5th thoracic vertebra. BSS after TEVAR is a rare phenomenon with a fairly good prognosis, depending on the initial injury severity.
    Language English
    Publishing date 2022-06-30
    Publishing country Korea (South)
    Document type Case Reports
    ISSN 2288-7970
    ISSN 2288-7970
    DOI 10.5758/vsi.220008
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  5. Article: Active aortic aneurysm sac treatment with shape memory polymer during endovascular aneurysm repair.

    Holden, Andrew / Hill, Andrew A / Khashram, Manar / Heyligers, Jan M M / Wiersema, Arno M / Hayes, Paul D / Reijnen, Michel M P J

    Journal of vascular surgery cases and innovative techniques

    2023  Volume 9, Issue 3, Page(s) 101241

    Abstract: Preprocedural image analysis and intraprocedural techniques to fully treat infrarenal abdominal aortic aneurysm sacs outside of the endograft with shape memory polymer (SMP) devices during endovascular aneurysm repair were developed. Prospective, ... ...

    Abstract Preprocedural image analysis and intraprocedural techniques to fully treat infrarenal abdominal aortic aneurysm sacs outside of the endograft with shape memory polymer (SMP) devices during endovascular aneurysm repair were developed. Prospective, multicenter, single-arm studies were performed. SMP is a porous, self-expanding polyurethane polymer material. Target lumen volumes (aortic flow lumen volume minus endograft volume) were estimated from the preprocedural imaging studies and endograft dimensions. SMP was delivered immediately after endograft deployment via a 6F sheath jailed in a bowed position in the sac. Technical success was achieved in all cases, defined as implanting enough fully expanded SMP volume to treat the actual target lumen volume.
    Language English
    Publishing date 2023-06-12
    Publishing country United States
    Document type Journal Article
    ISSN 2468-4287
    ISSN 2468-4287
    DOI 10.1016/j.jvscit.2023.101241
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  6. Article ; Online: Geometric Analysis of the Gore Excluder Conformable Endoprosthesis in the Infrarenal Aortic Neck: One Year Results of the EXCeL Registry.

    Zuidema, Roy / van Sambeek, Marc R H M / Zwetsloot, Jenny / Heyligers, Jan M M / Pratesi, Giovanni / Reijnen, Michel M P J / de Vries, Jean-Paul P M / Schuurmann, Richte C L

    European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery

    2024  

    Abstract: Objective: The Gore Excluder Conformable Endoprosthesis (CEXC) is designed to treat challenging infrarenal anatomy because of its active angulation control, repositionability, and enhanced conformability. This study evaluated 30 day and one year ... ...

    Abstract Objective: The Gore Excluder Conformable Endoprosthesis (CEXC) is designed to treat challenging infrarenal anatomy because of its active angulation control, repositionability, and enhanced conformability. This study evaluated 30 day and one year position and apposition of the CEXC in the infrarenal neck.
    Methods: Patients treated with the CEXC between 2018 and 2022 with an available 30 day computed tomography angiography (CTA) were selected from four hospitals in a prospective registry. Endograft apposition (shortest apposition length [SAL]) and position (shortest fabric distance [SFD]) were assessed on the 30 day and one year CTAs. Maximum infrarenal aortic curvature was compared between the pre-operative and post-operative CTAs to evaluate conformability of the CEXC.
    Results: There were 87 patients with a 30 day CTA, and for 56 of these patients the one year CTA was available. Median (interquartile range [IQR]) pre-operative neck length was 22 mm (IQR 15, 32) and infrarenal angulation was 52° (IQR 31, 72). Median SAL was 21.2 mm (IQR 14.0, 29.3) at 30 days for all included patients. The SAL in 13 patients (15%) was < 10 mm at 30 days, and one patient had a SAL of 0 mm and a type Ia endoleak. There was no significant difference in SAL between patients within and outside instructions for use. The SAL significantly increased by 1.1 mm (IQR -2.3, 4.7; p = .042) at 1 year. The SAL decreased in seven patients (13%), increased in 13 patients (23%), and remained stable in 36 patients (64%). Median SFD was 2.0 mm (IQR 0.5, 3.6) at 30 days, which slightly increased by 0.3 mm (IQR -0.5, 1.8; p = .019) at 1 year. One patient showed migration (SFD increase ≥ 5 mm). Median endograft tilt was 15.8° (IQR 9.7, 21.4). Pre-operative maximum infrarenal curvature was 36 m
    Conclusion: In most patients, the CEXC was implanted close to the renal arteries, and sufficient (≥ 10 mm) post-operative apposition was acquired at 30 days, which slightly increased at one year. Post-operative endograft tilt was relatively low, and aortic geometry remained unchanged after implantation of the CEXC, probably due to its high conformability.
    Language English
    Publishing date 2024-04-24
    Publishing country England
    Document type Journal Article
    ZDB-ID 1225869-6
    ISSN 1532-2165 ; 1078-5884
    ISSN (online) 1532-2165
    ISSN 1078-5884
    DOI 10.1016/j.ejvs.2024.04.026
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  7. Article: Comparison of segmentation software packages for in-hospital 3D print workflow.

    Wijnen, Niek / Brouwers, Lars / Jebbink, Erik Groot / Heyligers, Jan M M / Bemelman, Mike

    Journal of medical imaging (Bellingham, Wash.)

    2021  Volume 8, Issue 3, Page(s) 34004

    Abstract: Purpose: ...

    Abstract Purpose:
    Language English
    Publishing date 2021-06-30
    Publishing country United States
    Document type Journal Article
    ISSN 2329-4302
    ISSN 2329-4302
    DOI 10.1117/1.JMI.8.3.034004
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  8. Article ; Online: Histological evaluation of the aortic wall response following endovascular aneurysm repair and endovascular aneurysm sealing.

    Bruijn, Laura E / Heyligers, Jan M M / Vriens, Patrick W / van Rhijn, Jacoba / Roy, Joy / Hamming, Jaap F / Gäbel, Gabor / Lindeman, Jan H N

    JVS-vascular science

    2023  Volume 4, Page(s) 100101

    Abstract: Objective: The Nellix endovascular aneurysm sealing (EVAS) system was developed as an alternative to conventional endovascular aneurysm repair (EVAR) to minimize endoleaks. A significantly higher failure rate of EVAS may be related to an interaction ... ...

    Abstract Objective: The Nellix endovascular aneurysm sealing (EVAS) system was developed as an alternative to conventional endovascular aneurysm repair (EVAR) to minimize endoleaks. A significantly higher failure rate of EVAS may be related to an interaction between the filled endobags and the AAA wall. In general, biological information on aortic remodeling after traditional EVAR is scarce. In this light, we provide here the first histologic evaluation of aneurysm wall morphology after EVAR and EVAS.
    Methods: Fourteen histological human wall samples of EVAS and EVAR explantation were systematically analysed. Primary open aorta repair samples were included as reference.
    Results: Compared with primary open aortic repair samples, endovascular repair aortic samples were characterized by more pronounced fibrosis, a greater number of ganglionic structures, decreased cellular inflammation, less calcification, and a lower atherosclerotic load. EVAS was specifically associated with the presence of unstructured elastin deposits.
    Conclusions: The biological response of the aortic wall after endovascular repair resembles the maturation process of a scar rather than a bona fide healing response. Moreover, the inflammatory response in the aortic wall after placement of endovascular protheses is less prominent than after primary open repair. A specific post-EVAS aortic wall characteristic was unstructured elastin fragments.
    Language English
    Publishing date 2023-03-23
    Publishing country United States
    Document type Journal Article
    ISSN 2666-3503
    ISSN (online) 2666-3503
    DOI 10.1016/j.jvssci.2023.100101
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  9. Article ; Online: The Dutch chronic lower limb-threatening ischemia registry (THRILLER): A study protocol for popliteal and infrapopliteal endovascular interventions.

    Nugteren, Michael J / Hazenberg, Constantijn E V B / Akkersdijk, George P / Bakker, Olaf J / Dinkelman, Maarten K / Fioole, Bram / van den Heuvel, Daniel A F / Heyligers, Jan M M / Hinnen, Jan-Willem / Pierie, Maurice / Schouten, Olaf / Schreve, Michiel A / Verhoeven, Bart A N / de Borst, Gert J / Ünlü, Çağdaş

    PloS one

    2023  Volume 18, Issue 7, Page(s) e0288912

    Abstract: Introduction: Chronic limb-threatening ischemia (CLTI) is the end stage of peripheral arterial disease (PAD) and is associated with high amputation rates, mortality and disease-related health care costs. In infrapopliteal arterial disease (IPAD), ... ...

    Abstract Introduction: Chronic limb-threatening ischemia (CLTI) is the end stage of peripheral arterial disease (PAD) and is associated with high amputation rates, mortality and disease-related health care costs. In infrapopliteal arterial disease (IPAD), endovascular revascularization should be considered for the majority of anatomical and clinical subgroups of CLTI. However, a gap of high-quality evidence exists in this field. The aim of the Dutch Chronic Lower Limb-Threatening Ischemia Registry (THRILLER) is to collect real world data on popliteal and infrapopliteal endovascular interventions.
    Methods: THRILLER is a clinician-driven, prospective, multicenter, observational registry including all consecutive patients that undergo a popliteal or infrapopliteal endovascular intervention in seven Dutch hospitals. We estimate that THRILLER will include 400-500 interventions annually. Standardized follow-up visits with wound monitoring, toe pressure measurement and duplex ultrasonography will be scheduled at 6-8 weeks and 12 months after the intervention. The independent primary endpoints are primary patency, limb salvage and amputation free survival. Patients must give informed consent before participation and will be included according to predefined reporting standards. A data log of patients who meet the inclusion criteria but are not included in the registry will be maintained. We intend to conduct the first interim analysis two years after the start of inclusion. The results will be published in a scientific journal.
    Discussion: Despite innovations in medical therapy and revascularization techniques, patients with CLTI undergoing endovascular revascularization still have a moderate prognosis. Previous prospective cohort studies were hampered by small sample sizes or heterogeneous reporting. Randomized controlled trials (RCTs) have high costs, potential conflicts of interest and give a limited reflection of daily practice. THRILLER aims to provide the largest prospective well phenotyped up-to-date dataset on treatment outcomes in CLTI patients to answer multiple underexplored research questions regarding diagnostics, medication, patient selection, treatment strategies and post intervention follow-up.
    MeSH term(s) Humans ; Chronic Disease ; Chronic Limb-Threatening Ischemia ; Endovascular Procedures/methods ; Ischemia/surgery ; Limb Salvage ; Lower Extremity ; Multicenter Studies as Topic ; Peripheral Arterial Disease/diagnostic imaging ; Peripheral Arterial Disease/surgery ; Registries ; Retrospective Studies ; Risk Factors ; Treatment Outcome ; Vascular Patency ; Observational Studies as Topic
    Language English
    Publishing date 2023-07-20
    Publishing country United States
    Document type Journal Article ; Research Support, Non-U.S. Gov't
    ZDB-ID 2267670-3
    ISSN 1932-6203 ; 1932-6203
    ISSN (online) 1932-6203
    ISSN 1932-6203
    DOI 10.1371/journal.pone.0288912
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  10. Article ; Online: Nationwide Experience with EVAS Relining of Previous Open or Endovascular AAA Treatment in The Netherlands.

    Ketting, Shirley / Zoethout, Aleksandra C / Heyligers, Jan M M / Wiersema, Arno M / Yeung, Kak K / Schurink, Geert W H / Verhagen, Hence J M / de Vries, Jean-Paul P M / Reijnen, Michel M P J / Mees, Barend M E

    Annals of vascular surgery

    2022  Volume 84, Page(s) 250–264

    Abstract: Objective: Relining of a previously placed surgical graft or endograft for an abdominal aortic aneurysm (AAA) is a reintervention to treat progression of disease or failure of the primary (endo)graft. Endovascular Aneurysm Sealing (EVAS) relining is a ... ...

    Abstract Objective: Relining of a previously placed surgical graft or endograft for an abdominal aortic aneurysm (AAA) is a reintervention to treat progression of disease or failure of the primary (endo)graft. Endovascular Aneurysm Sealing (EVAS) relining is a technique with potential advantages due to the absence of a bifurcation, the possibility for a unilateral approach, and sealing concept of the endobags. The purpose of this study was to describe the nationwide experience with EVAS relining of previous AAA repair in the Netherlands.
    Methods: A retrospective analysis of all patients who underwent EVAS relining in 7 high volume vascular centres in the Netherlands between 2014 and 2019 was performed. Primary outcomes were technical and clinical success. Secondary outcomes were perioperative outcomes, complications and survival.
    Results: Thirty-three patients underwent EVAS relining of open (n = 10) or endovascular (n = 23) repair. 26 were elective cases, 5 were urgent and 2 were acute (ruptured). Mean time between primary treatment and EVAS relining was 99 ± 74 months. Indications after open repair were proximal progression of disease (n = 7) and graft defect (n = 3). Indications after EVAR were type IA (n = 10), type IB (n = 3), type IIIA (n = 4), type IIIB (n = 3) endoleak, and endotension (n = 3). 18 patients underwent regular EVAS, 4 unilateral EVAS and 11 chimney-EVAS. In-hospital mortality was 6% (both patients with rAAA). Technical success was achieved in 97%. Median follow-up after EVAS relining was 20 months (range 0-43). Freedom from reintervention at 1-year and 2-year were 83% and 61% and the estimated survival 79% and 71%, respectively. EVAS relining after open repair had a clinical success of 90% at 1-year and of 70% at latest follow-up, while after EVAR clinical success rates were 70% and 52%, respectively.
    Conclusion: EVAS relining of previous AAA repair is associated with high technical success, however with limited clinical success at median follow-up of 20 months. Clinical success was higher in patients with EVAS relining after open repair than after EVAR. In patients with failed AAA repair, EVAS relining should only be considered, when established techniques such as fenestrated repair or open conversion are not available or indicated.
    MeSH term(s) Aortic Aneurysm, Abdominal/diagnostic imaging ; Aortic Aneurysm, Abdominal/surgery ; Blood Vessel Prosthesis ; Blood Vessel Prosthesis Implantation ; Endovascular Procedures ; Humans ; Netherlands ; Prosthesis Design ; Retrospective Studies ; Time Factors ; Treatment Outcome
    Language English
    Publishing date 2022-01-05
    Publishing country Netherlands
    Document type Journal Article
    ZDB-ID 1027366-9
    ISSN 1615-5947 ; 0890-5096
    ISSN (online) 1615-5947
    ISSN 0890-5096
    DOI 10.1016/j.avsg.2021.12.077
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

To top