LIVIVO - The Search Portal for Life Sciences

zur deutschen Oberfläche wechseln
Advanced search

Search results

Result 1 - 4 of total 4

Search options

  1. Article ; Online: Cold Temperature Direct Air CO

    Wang, Yuxiang / Rim, Guanhe / Song, MinGyu / Holmes, Hannah E / Jones, Christopher W / Lively, Ryan P

    ACS applied materials & interfaces

    2023  Volume 16, Issue 1, Page(s) 1404–1415

    Abstract: Zeolites, silica-supported amines, and metal-organic frameworks (MOFs) have been demonstrated as promising adsorbents for direct air ... ...

    Abstract Zeolites, silica-supported amines, and metal-organic frameworks (MOFs) have been demonstrated as promising adsorbents for direct air CO
    Language English
    Publishing date 2023-12-18
    Publishing country United States
    Document type Journal Article
    ISSN 1944-8252
    ISSN (online) 1944-8252
    DOI 10.1021/acsami.3c13528
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  2. Article: Outcomes of percutaneous vertebroplasty in multiple myeloma: a tertiary neurosciences experience with long-term follow-up.

    Holmes, Hannah E / Balian, Vartan / Kular, Saminderjit / Batty, Ruth / Connolly, Daniel J A / Chantry, Andrew / Martin, Andrew

    Frontiers in oncology

    2024  Volume 14, Page(s) 1291055

    Abstract: Background: Multiple myeloma is diagnosed in 5,800 people in the United Kingdom (UK) each year with up to 64% having vertebral compression fractures at the time of diagnosis. Painful vertebral compression fractures can be of significant detriment to ... ...

    Abstract Background: Multiple myeloma is diagnosed in 5,800 people in the United Kingdom (UK) each year with up to 64% having vertebral compression fractures at the time of diagnosis. Painful vertebral compression fractures can be of significant detriment to patients' quality of life. Percutaneous vertebroplasty aims to provide long-term pain relief and stabilize fractured vertebrae.
    Methods and materials: Data was collected from all cases of percutaneous vertebroplasty performed on patients with multiple myeloma from November 2017 to January 2019. Pain scores were measured using the Visual Analogue Scale (VAS) and Oswestry Disability Index (ODI) pre-procedure, 2 months post procedure and 4 years post-procedure. Procedure related complications and analgesia use were also documented.
    Results: 22 patients were included with a total of 119 vertebrae treated. Patients reported a significant improvement in overall pain score with a median pre-procedure VAS of 8 and a median post-procedure VAS of 3.5 (p<0.0001). There was a median pre-procedure ODI score of 60% and a median post-procedure ODI score of 36% (p<0000.1). There was improvement across all ODI domains and a 77% reduction in analgesic requirement. There were small cement leaks into paravertebral veins or endplates at 15 levels (12%) which were asymptomatic. There were 8 responders to the long-term follow-up questionnaire at 4 years. This demonstrated an overall stable degree of pain relief in responders with a median VAS of 3.5 and median ODI of 30%.
    Conclusion: At this center, vertebroplasty has been shown to reduce both VAS and ODI pain scores and reduce analgesia requirements in patients with VCFs secondary to multiple myeloma with long lasting relief at 4 years post-procedure.
    Language English
    Publishing date 2024-04-11
    Publishing country Switzerland
    Document type Journal Article
    ZDB-ID 2649216-7
    ISSN 2234-943X
    ISSN 2234-943X
    DOI 10.3389/fonc.2024.1291055
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  3. Article ; Online: Defining Targets for Adsorbent Material Performance to Enable Viable BECCS Processes.

    Holmes, Hannah E / Lively, Ryan P / Realff, Matthew J

    JACS Au

    2021  Volume 1, Issue 6, Page(s) 795–806

    Abstract: Target properties of ... ...

    Abstract Target properties of CO
    Language English
    Publishing date 2021-05-06
    Publishing country United States
    Document type Journal Article
    ISSN 2691-3704
    ISSN (online) 2691-3704
    DOI 10.1021/jacsau.0c00127
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  4. Article ; Online: Scalable Formation of Diamine-Appended Metal-Organic Framework Hollow Fiber Sorbents for Postcombustion CO

    Quan, Wenying / Holmes, Hannah E / Zhang, Fengyi / Hamlett, Breanne L / Finn, M G / Abney, Carter W / Kapelewski, Matthew T / Weston, Simon C / Lively, Ryan P / Koros, William J

    JACS Au

    2022  Volume 2, Issue 6, Page(s) 1350–1358

    Abstract: We describe a straightforward and scalable fabrication of diamine-appended metal-organic framework (MOF)/polymer composite hollow fiber sorbent modules for ... ...

    Abstract We describe a straightforward and scalable fabrication of diamine-appended metal-organic framework (MOF)/polymer composite hollow fiber sorbent modules for CO
    Language English
    Publishing date 2022-05-16
    Publishing country United States
    Document type Journal Article
    ISSN 2691-3704
    ISSN (online) 2691-3704
    DOI 10.1021/jacsau.2c00029
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

To top