LIVIVO - The Search Portal for Life Sciences

zur deutschen Oberfläche wechseln
Advanced search

Search results

Result 1 - 7 of total 7

Search options

  1. Article ; Online: Long-term efficacy of sodium-glucose cotransporter 2 inhibitor therapy in preventing atrial fibrillation recurrence after catheter ablation in type 2 diabetes mellitus patients

    Hao-Tien Liu / Hung-Ta Wo / Po-Cheng Chang / Hui-Ling Lee / Ming-Shien Wen / Chung-Chuan Chou

    Heliyon, Vol 9, Iss 6, Pp e16835- (2023)

    2023  

    Abstract: Background: Sodium-glucose cotransporter 2 inhibitors (SGLT2i) reduce new-onset atrial fibrillation (AF) in patients with type 2 diabetes mellitus (T2DM). We aimed to determine the long-term effects of SGLT2i on atrial tachyarrhythmia recurrence after ... ...

    Abstract Background: Sodium-glucose cotransporter 2 inhibitors (SGLT2i) reduce new-onset atrial fibrillation (AF) in patients with type 2 diabetes mellitus (T2DM). We aimed to determine the long-term effects of SGLT2i on atrial tachyarrhythmia recurrence after catheter ablation (CA) in T2DM patients. Methods: This retrospective study enrolled consecutive patients with T2DM undergoing CA for AF between January 2016 and December 2021. Patient baseline demographic characteristics and use of anti-diabetic and anti-arrhythmic medications were analyzed. Echocardiographic parameters were obtained one day and 6 months after CA. Results: Our study population comprised 122 patients (70% paroxysmal AF). The baseline patient characteristics were similar between the SGLT2i-treated group (n = 45) and the non-SGLT2i-treated group (n = 77) except for stroke. At 6-month follow-up, body-mass index (BMI) was significantly decreased and left ventricular ejection fraction (LVEF) was significantly increased only in the SGLT2i group. E/e’ was decreased 6 months after CA in both groups. During a mean follow-up of 33.7 ± 21.6 months, 22 of 122 patients had atrial tachyarrhythmia recurrence. The long-term atrial tachyarrhythmia-free survival rate was significantly higher in the SGLT2i-treated patients, and multivariate analysis revealed that AF type and SGLT2i use were independently associated with atrial tachyarrhythmia recurrence after CA. Conclusion: The use of SGLT2i and AF type were independent risk factors associated with atrial tachyarrhythmia recurrence after CA in T2DM patients with AF. This result was at least partly due to the pleiotropic effects of SGLT2i on BMI reduction and left ventricular function improvement.
    Keywords Atrial fibrillation ; Catheter ablation ; Sodium-glucose cotransporter 2 inhibitors ; Type 2 diabetes mellitus ; Science (General) ; Q1-390 ; Social sciences (General) ; H1-99
    Subject code 616
    Language English
    Publishing date 2023-06-01T00:00:00Z
    Publisher Elsevier
    Document type Article ; Online
    Database BASE - Bielefeld Academic Search Engine (life sciences selection)

    More links

    Kategorien

  2. Article ; Online: Differential Responses of Transplanted Stem Cells to Diseased Environment Unveiled by a Molecular NIR-II Cell Tracker

    Hao Chen / Huaxiao Yang / Chen Zhang / Si Chen / Xin Zhao / Mark Zhu / Zhiming Wang / Yuebing Wang / Hung-Ta Wo / Kai Li / Zhen Cheng

    Research, Vol

    2021  Volume 2021

    Abstract: Stem cell therapy holds high promises in regenerative medicine. The major challenge of clinical translation is to precisely and quantitatively evaluate the in vivo cell distribution, migration, and engraftment, which cannot be easily achieved by current ... ...

    Abstract Stem cell therapy holds high promises in regenerative medicine. The major challenge of clinical translation is to precisely and quantitatively evaluate the in vivo cell distribution, migration, and engraftment, which cannot be easily achieved by current techniques. To address this issue, for the first time, we have developed a molecular cell tracker with a strong fluorescence signal in the second near-infrared (NIR-II) window (1,000-1,700 nm) for real-time monitoring of in vivo cell behaviors in both healthy and diseased animal models. The NIR-II tracker (CelTrac1000) has shown complete cell labeling with low cytotoxicity and profound long-term tracking ability for 30 days in high spatiotemporal resolution for semiquantification of the biodistribution of transplanted stem cells. Taking advantage of the unique merits of CelTrac1000, the responses of transplanted stem cells to different diseased environments have been discriminated and unveiled. Furthermore, we also demonstrate CelTrac1000 as a universal and effective technique for ultrafast real-time tracking of the cellular migration and distribution in a 100 μm single-cell cluster spatial resolution, along with the lung contraction and heart beating. As such, this NIR-II tracker will shift the optical cell tracking into a single-cell cluster and millisecond temporal resolution for better evaluating and understanding stem cell therapy, affording optimal doses and efficacy.
    Keywords Science ; Q
    Subject code 571
    Language English
    Publishing date 2021-01-01T00:00:00Z
    Publisher American Association for the Advancement of Science
    Document type Article ; Online
    Database BASE - Bielefeld Academic Search Engine (life sciences selection)

    More links

    Kategorien

  3. Article ; Online: Clinical Outcomes of low-voltage area-guided left atrial linear ablation for non-paroxysmal atrial fibrillation patients.

    Hao-Tien Liu / Chia-Hung Yang / Hui-Ling Lee / Po-Cheng Chang / Hung-Ta Wo / Ming-Shien Wen / Chun-Chieh Wang / San-Jou Yeh / Chung-Chuan Chou

    PLoS ONE, Vol 16, Iss 12, p e

    2021  Volume 0260834

    Abstract: Background The therapeutic effect of low-voltage area (LVA)-guided left atrial (LA) linear ablation for non-paroxysmal atrial fibrillation (non-PAF) is uncertain. We aimed to investigate the efficacy of LA linear ablation based on the preexisting LVA and ...

    Abstract Background The therapeutic effect of low-voltage area (LVA)-guided left atrial (LA) linear ablation for non-paroxysmal atrial fibrillation (non-PAF) is uncertain. We aimed to investigate the efficacy of LA linear ablation based on the preexisting LVA and its effects on LA reverse remodeling in non-PAF patients. Methods We retrospectively evaluated 145 consecutive patients who underwent radiofrequency catheter ablation for drug-refractory non-PAF. CARTO-guided bipolar voltage mapping was performed in atrial fibrillation (AF). LVA was defined as sites with voltage ≤ 0.5 mV. If circumferential pulmonary vein isolation couldn't convert AF into sinus rhythm, additional LA linear ablation was performed preferentially at sites within LVA. Results After a mean follow-up duration of 48 ± 33 months, 29 of 145 patients had drugs-refractory AF/LA tachycardia recurrence. Low LA emptying fraction, large LA size and high extent of LVA were associated with AF recurrence. There were 136 patients undergoing LA linear ablation. The rate of linear block at the mitral isthmus was significantly higher via LVA-guided than non-LVA-guided linear ablation. Patients undergoing LVA-guided linear ablation had larger LA size and higher extent of LVA, but the long-term AF/LA tachycardia-free survival rate was higher than the non-LVA-guided group. The LA reverse remodeling effects by resuming sinus rhythm were noted even in patients with a diseased left atrium undergoing extensive LA linear ablation. Conclusions LVA-guided linear ablation through targeting the arrhythmogenic LVA and reducing LA mass provides a better clinical outcome than non-LVA guided linear ablation, and outweighs the harmful effects of iatrogenic scaring in non-PAF patients.
    Keywords Medicine ; R ; Science ; Q
    Subject code 616
    Language English
    Publishing date 2021-01-01T00:00:00Z
    Publisher Public Library of Science (PLoS)
    Document type Article ; Online
    Database BASE - Bielefeld Academic Search Engine (life sciences selection)

    More links

    Kategorien

  4. Article ; Online: Left atrial emptying fraction predicts recurrence of atrial fibrillation after radiofrequency catheter ablation.

    Chung-Chuan Chou / Hui-Ling Lee / Po-Cheng Chang / Hung-Ta Wo / Ming-Shien Wen / San-Jou Yeh / Fen-Chiung Lin / Yi-Ting Hwang

    PLoS ONE, Vol 13, Iss 1, p e

    2018  Volume 0191196

    Abstract: Compared with left atrial (LA) dimension, LA emptying fraction (LAEF) has received less emphasis as a predictor of atrial fibrillation (AF) recurrence after radiofrequency catheter ablation (RFCA). In addition, patients experiencing post-RFCA AF ... ...

    Abstract Compared with left atrial (LA) dimension, LA emptying fraction (LAEF) has received less emphasis as a predictor of atrial fibrillation (AF) recurrence after radiofrequency catheter ablation (RFCA). In addition, patients experiencing post-RFCA AF recurrence may respond to previously ineffective antiarrhythmic drugs (AADs). Classifying these patients into a third RFCA outcome category is recommended.To identify predictors of RFCA outcome classified into three categories, and to build proportional odds logistic regression models for clinical applicability to predict AF recurrence.Data were retrospectively collected from 483 consecutive patients with drug-refractory AF undergoing RFCA (328 men; age 58.4 ± 11.5 years; 383 paroxysmal). Patients were classified into 3 groups based on the last RFCA outcome: group 1, free from AF without AADs; group 2, free from AF with AADs; and group 3, recurrence of AADs-refractory atrial tachyarrhythmia.After a mean follow-up duration of 64.5 ± 43.2 months and mean ablation procedure number of 1.37 ± 0.68, the RFCA outcome showed 76.0%, 9.5% and 14.5% of patients in groups 1, 2, and 3, respectively. In multivariate analysis, LAEF was the most stable and important predictor of AF recurrence, followed by body mass index, stroke, AF duration, mitral regurgitation, and LA linear ablation. For patients undergoing repeat RFCA, LAEF was the only independent predictor (cutoffs: 43% and 35% for groups 1 and 3, respectively).LAEF provides optimal prognostic information regarding the risk stratification of AF patients undergoing RFCA.
    Keywords Medicine ; R ; Science ; Q
    Subject code 616
    Language English
    Publishing date 2018-01-01T00:00:00Z
    Publisher Public Library of Science (PLoS)
    Document type Article ; Online
    Database BASE - Bielefeld Academic Search Engine (life sciences selection)

    More links

    Kategorien

  5. Article ; Online: Effects of Dantrolene on Arrhythmogenicity in Isolated Regional Ischemia-Reperfusion Rabbit Hearts with or without Pacing-Induced Heart Failure

    Chung-Chuan Chou / Hui-Ling Lee / Po-Cheng Chang / Hung-Ta Wo / Ming-Shien Wen / San-Jou Yeh

    BioMed Research International, Vol

    2015  Volume 2015

    Abstract: Dantrolene was reported to suppress ventricular fibrillation (VF) in failing hearts with acute myocardial infarction, but its antiarrhythmic efficacy in regional ischemia-reperfusion (IR) hearts remains debatable. Heart failure (HF) was induced by right ... ...

    Abstract Dantrolene was reported to suppress ventricular fibrillation (VF) in failing hearts with acute myocardial infarction, but its antiarrhythmic efficacy in regional ischemia-reperfusion (IR) hearts remains debatable. Heart failure (HF) was induced by right ventricular pacing. The IR rabbit model was created by coronary artery ligation for 30 min, followed by reperfusion for 15 min in vivo in both HF and non-HF groups (n = 9 in each group). Simultaneous voltage and intracellular Ca2+ (Cai) optical mapping was then performed in isolated Langendorff-perfused hearts. Electrophysiological studies were conducted and VF inducibility was evaluated by dynamic pacing. Dantrolene (10 μM) was administered after baseline studies. The HF group had a higher VF inducibility than the control group. Dantrolene had both antiarrhythmic (prolonged action potential duration (APD) and effective refractory period) and proarrhythmic effects (slowed conduction velocity, steepened APD restitution slope, and enhanced arrhythmogenic alternans induction) but had no significant effects on ventricular premature beat (VPB) suppression and VF inducibility in both groups. A higher VF conversion rate in the non-HF group was likely due to greater APD prolonging effects in smaller hearts compared to the HF group. The lack of significant effects on VPB suppression by dantrolene suggests that triggered activity might not be the dominant mechanism responsible for VPB induction in the IR model.
    Keywords Medicine ; R
    Subject code 610
    Language English
    Publishing date 2015-01-01T00:00:00Z
    Publisher Hindawi Limited
    Document type Article ; Online
    Database BASE - Bielefeld Academic Search Engine (life sciences selection)

    More links

    Kategorien

  6. Article ; Online: A meta-analysis of mortality in end-stage renal disease patients receiving implantable cardioverter defibrillators (ICDs).

    Tien-Hsing Chen / Hung-Ta Wo / Po-Cheng Chang / Chun-Chieh Wang / Ming-Shien Wen / Chung-Chuan Chou

    PLoS ONE, Vol 9, Iss 7, p e

    2014  Volume 99418

    Abstract: Data on the effectiveness of implantable implantable cardioverter defibrillators (ICDs) with respect to reducing mortality in patients with chronic kidney disease (CKD) and end-stage renal disease (ESRD) are lacking. The purpose of this meta-analysis was ...

    Abstract Data on the effectiveness of implantable implantable cardioverter defibrillators (ICDs) with respect to reducing mortality in patients with chronic kidney disease (CKD) and end-stage renal disease (ESRD) are lacking. The purpose of this meta-analysis was to compare the mortality of patients with ESRD who have received and not received an ICD. A search was conducted on January 31, 2013 of Medline, Cochrane, EMBASE, and Google Scholar. Studies were selected for inclusion based on the following criteria. 1) Randomized controlled trial. 2) ESRD patients with heart failure. 3) Device therapy (ICD, CRT-defibrillator [CRT-D]) used to treat heart failure. 4) Primary outcome is survival analysis. 5) Retrospective study if survival analysis was performed. The primary outcome was overall survival (OS), and the secondary outcome was 2-year survival. Odds ratios (ORs) with 95% confidence intervals (CI) were calculated, and a χ2-based test of homogeneity was performed. Three studies were included in the analysis. The combined OR for OS was 2.245 (95% CI 1.871 to 2.685, P<0.001), indicating that patients with an ICD had a significantly higher OS than those without an ICD. The combined OR for 2-year survival was 2.312 (95% CI 1.921 to 2.784, P<0.001), indicating that patients with an ICD had a significantly higher 2-year survival rate than those without an ICD. The use of ICD in patients with ESRD is associated with an increase in the OS and the 2-year survival rate.
    Keywords Medicine ; R ; Science ; Q
    Subject code 616 ; 610
    Language English
    Publishing date 2014-01-01T00:00:00Z
    Publisher Public Library of Science (PLoS)
    Document type Article ; Online
    Database BASE - Bielefeld Academic Search Engine (life sciences selection)

    More links

    Kategorien

  7. Article ; Online: Role of sarcoplasmic reticulum calcium in development of secondary calcium rise and early afterdepolarizations in long QT syndrome rabbit model.

    Po-Cheng Chang / Hung-Ta Wo / Hui-Ling Lee / Shien-Fong Lin / Ming-Shien Wen / Yen Chu / San-Jou Yeh / Chung-Chuan Chou

    PLoS ONE, Vol 10, Iss 4, p e

    2015  Volume 0123868

    Abstract: BACKGROUND:L-type calcium current reactivation plays an important role in development of early afterdepolarizations (EADs) and torsades de pointes (TdP). Secondary intracellular calcium (Cai) rise is associated with initiation of EADs. OBJECTIVE:To test ... ...

    Abstract BACKGROUND:L-type calcium current reactivation plays an important role in development of early afterdepolarizations (EADs) and torsades de pointes (TdP). Secondary intracellular calcium (Cai) rise is associated with initiation of EADs. OBJECTIVE:To test whether inhibition of sarcoplasmic reticulum (SR) Ca2+ cycling suppresses secondary Cai rise and genesis of EADs. METHODS:Langendorff perfusion and dual voltage and Cai optical mapping were conducted in 10 rabbit hearts. Atrioventricular block (AVB) was created by radiofrequency ablation. After baseline studies, E4031, SR Ca2+ cycling inhibitors (ryanodine plus thapsigargin) and nifedipine were then administrated subsequently, and the protocols were repeated. RESULTS:At baseline, there was no spontaneous or pacing-induced TdP. After E4031 administration, action potential duration (APD) was significantly prolonged and the amplitude of secondary Cai rise was enhanced, and 7 (70%) rabbits developed spontaneous or pacing-induced TdP. In the presence of ryanodine plus thapsigargin, TdP inducibility was significantly reduced (2 hearts, 20%, p = 0.03). Although APD was significantly prolonged (from 298 ± 30 ms to 457 ± 75 ms at pacing cycle length of 1000 m, p = 0.007) by ryanodine plus thapsigargin, the secondary Cai rise was suppressed (from 8.8 ± 2.6% to 1.2 ± 0.9%, p = 0.02). Nifedipine inhibited TdP inducibility in all rabbit hearts. CONCLUSION:In this AVB and long QT rabbit model, inhibition of SR Ca2+ cycyling reduces the inducibility of TdP. The mechanism might be suppression of secondary Cai rise and genesis of EADs.
    Keywords Medicine ; R ; Science ; Q
    Subject code 572
    Language English
    Publishing date 2015-01-01T00:00:00Z
    Publisher Public Library of Science (PLoS)
    Document type Article ; Online
    Database BASE - Bielefeld Academic Search Engine (life sciences selection)

    More links

    Kategorien

To top