LIVIVO - The Search Portal for Life Sciences

zur deutschen Oberfläche wechseln
Advanced search

Search results

Result 1 - 4 of total 4

Search options

  1. Article ; Online: Exploration of differentiability in a proton computed tomography simulation framework.

    Aehle, Max / Alme, Johan / Gábor Barnaföldi, Gergely / Blühdorn, Johannes / Bodova, Tea / Borshchov, Vyacheslav / van den Brink, Anthony / Eikeland, Viljar / Feofilov, Gregory / Garth, Christoph / Gauger, Nicolas R / Grøttvik, Ola / Helstrup, Håvard / Igolkin, Sergey / Keidel, Ralf / Kobdaj, Chinorat / Kortus, Tobias / Kusch, Lisa / Leonhardt, Viktor /
    Mehendale, Shruti / Ningappa Mulawade, Raju / Harald Odland, Odd / O'Neill, George / Papp, Gábor / Peitzmann, Thomas / Pettersen, Helge Egil Seime / Piersimoni, Pierluigi / Pochampalli, Rohit / Protsenko, Maksym / Rauch, Max / Ur Rehman, Attiq / Richter, Matthias / Röhrich, Dieter / Sagebaum, Max / Santana, Joshua / Schilling, Alexander / Seco, Joao / Songmoolnak, Arnon / Sudár, Ákos / Tambave, Ganesh / Tymchuk, Ihor / Ullaland, Kjetil / Varga-Kofarago, Monika / Volz, Lennart / Wagner, Boris / Wendzel, Steffen / Wiebel, Alexander / Xiao, RenZheng / Yang, Shiming / Zillien, Sebastian

    Physics in medicine and biology

    2023  Volume 68, Issue 24

    Abstract: Objective. ...

    Abstract Objective.
    MeSH term(s) Computer Simulation ; Protons ; Phantoms, Imaging ; Tomography, X-Ray Computed/methods ; Software ; Algorithms ; Monte Carlo Method
    Chemical Substances Protons
    Language English
    Publishing date 2023-12-15
    Publishing country England
    Document type Review ; Journal Article
    ZDB-ID 208857-5
    ISSN 1361-6560 ; 0031-9155
    ISSN (online) 1361-6560
    ISSN 0031-9155
    DOI 10.1088/1361-6560/ad0bdd
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  2. Article ; Online: Uncertainty-aware spot rejection rate as quality metric for proton therapy using a digital tracking calorimeter.

    Schilling, Alexander / Aehle, Max / Alme, Johan / Barnaföldi, Gergely Gábor / Bodova, Tea / Borshchov, Vyacheslav / van den Brink, Anthony / Eikeland, Viljar / Feofilov, Gregory / Garth, Christoph / Gauger, Nicolas R / Grøttvik, Ola / Helstrup, Håvard / Igolkin, Sergey / Keidel, Ralf / Kobdaj, Chinorat / Kortus, Tobias / Leonhardt, Viktor / Mehendale, Shruti /
    Ningappa Mulawade, Raju / Harald Odland, Odd / O'Neill, George / Papp, Gábor / Peitzmann, Thomas / Pettersen, Helge Egil Seime / Piersimoni, Pierluigi / Protsenko, Maksym / Rauch, Max / Ur Rehman, Attiq / Richter, Matthias / Röhrich, Dieter / Santana, Joshua / Seco, Joao / Songmoolnak, Arnon / Sudár, Ákos / Tambave, Ganesh / Tymchuk, Ihor / Ullaland, Kjetil / Varga-Kofarago, Monika / Volz, Lennart / Wagner, Boris / Wendzel, Steffen / Wiebel, Alexander / Xiao, RenZheng / Yang, Shiming / Zillien, Sebastian

    Physics in medicine and biology

    2023  Volume 68, Issue 19

    Abstract: Objective. ...

    Abstract Objective.
    MeSH term(s) Proton Therapy ; Uncertainty ; Protons ; Machine Learning ; Neural Networks, Computer
    Chemical Substances Protons
    Language English
    Publishing date 2023-09-20
    Publishing country England
    Document type Journal Article ; Research Support, Non-U.S. Gov't
    ZDB-ID 208857-5
    ISSN 1361-6560 ; 0031-9155
    ISSN (online) 1361-6560
    ISSN 0031-9155
    DOI 10.1088/1361-6560/acf5c2
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  3. Article ; Online: Investigating particle track topology for range telescopes in particle radiography using convolutional neural networks.

    Pettersen, Helge Egil Seime / Aehle, Max / Alme, Johan / Barnaföldi, Gergely Gábor / Borshchov, Vyacheslav / van den Brink, Anthony / Chaar, Mamdouh / Eikeland, Viljar / Feofilov, Grigory / Garth, Christoph / Gauger, Nicolas R / Genov, Georgi / Grøttvik, Ola / Helstrup, Håvard / Igolkin, Sergey / Keidel, Ralf / Kobdaj, Chinorat / Kortus, Tobias / Leonhardt, Viktor /
    Mehendale, Shruti / Mulawade, Raju Ningappa / Odland, Odd Harald / Papp, Gábor / Peitzmann, Thomas / Piersimoni, Pierluigi / Protsenko, Maksym / Rehman, Attiq Ur / Richter, Matthias / Santana, Joshua / Schilling, Alexander / Seco, Joao / Songmoolnak, Arnon / Sølie, Jarle Rambo / Tambave, Ganesh / Tymchuk, Ihor / Ullaland, Kjetil / Varga-Kofarago, Monika / Volz, Lennart / Wagner, Boris / Wendzel, Steffen / Wiebel, Alexander / Xiao, RenZheng / Yang, Shiming / Yokoyama, Hiroki / Zillien, Sebastian / Röhrich, Dieter

    Acta oncologica (Stockholm, Sweden)

    2021  Volume 60, Issue 11, Page(s) 1413–1418

    Abstract: Background: Proton computed tomography (pCT) and radiography (pRad) are proposed modalities for improved treatment plan accuracy and : Material and methods: The CNN was trained by simulation and reconstruction of tens of millions of proton and helium ...

    Abstract Background: Proton computed tomography (pCT) and radiography (pRad) are proposed modalities for improved treatment plan accuracy and
    Material and methods: The CNN was trained by simulation and reconstruction of tens of millions of proton and helium tracks. The CNN filter was then compared to simple energy loss threshold methods using the Area Under the Receiver Operating Characteristics curve (AUROC), and by comparing the image quality and Water Equivalent Path Length (WEPL) error of proton and helium radiographs filtered with the same methods.
    Results: The CNN method led to a considerable improvement of the AUROC, from 74.3% to 97.5% with protons and from 94.2% to 99.5% with helium. The CNN filtering reduced the WEPL error in the helium radiograph from 1.03 mm to 0.93 mm while no improvement was seen in the CNN filtered pRads.
    Conclusion: The CNN improved the filtering of proton and helium tracks. Only in the helium radiograph did this lead to improved image quality.
    MeSH term(s) Humans ; Image Processing, Computer-Assisted ; Monte Carlo Method ; Neural Networks, Computer ; Phantoms, Imaging ; Radiography ; Telescopes
    Language English
    Publishing date 2021-07-14
    Publishing country England
    Document type Journal Article
    ZDB-ID 896449-x
    ISSN 1651-226X ; 0349-652X ; 0284-186X ; 1100-1704
    ISSN (online) 1651-226X
    ISSN 0349-652X ; 0284-186X ; 1100-1704
    DOI 10.1080/0284186X.2021.1949037
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  4. Book ; Online: Exploration of Differentiability in a Proton Computed Tomography Simulation Framework

    Aehle, Max / Alme, Johan / Barnaföldi, Gergely Gábor / Blühdorn, Johannes / Bodova, Tea / Borshchov, Vyacheslav / Brink, Anthony van den / Eikeland, Viljar / Feofilov, Gregory / Garth, Christoph / Gauger, Nicolas R. / Grøttvik, Ola / Helstrup, Håvard / Igolkin, Sergey / Keidel, Ralf / Kobdaj, Chinorat / Kortus, Tobias / Kusch, Lisa / Leonhardt, Viktor /
    Mehendale, Shruti / Mulawade, Raju Ningappa / Odland, Odd Harald / O'Neill, George / Papp, Gábor / Peitzmann, Thomas / Pettersen, Helge Egil Seime / Piersimoni, Pierluigi / Pochampalli, Rohit / Protsenko, Maksym / Rauch, Max / Rehman, Attiq Ur / Richter, Matthias / Röhrich, Dieter / Sagebaum, Max / Santana, Joshua / Schilling, Alexander / Seco, Joao / Songmoolnak, Arnon / Sudár, Ákos / Tambave, Ganesh / Tymchuk, Ihor / Ullaland, Kjetil / Varga-Kofarago, Monika / Volz, Lennart / Wagner, Boris / Wendzel, Steffen / Wiebel, Alexander / Xiao, RenZheng / Yang, Shiming / Zillien, Sebastian

    2022  

    Abstract: Objective. Algorithmic differentiation (AD) can be a useful technique to numerically optimize design and algorithmic parameters by, and quantify uncertainties in, computer simulations. However, the effectiveness of AD depends on how "well-linearizable" ... ...

    Abstract Objective. Algorithmic differentiation (AD) can be a useful technique to numerically optimize design and algorithmic parameters by, and quantify uncertainties in, computer simulations. However, the effectiveness of AD depends on how "well-linearizable" the software is. In this study, we assess how promising derivative information of a typical proton computed tomography (pCT) scan computer simulation is for the aforementioned applications. Approach. This study is mainly based on numerical experiments, in which we repeatedly evaluate three representative computational steps with perturbed input values. We support our observations with a review of the algorithmic steps and arithmetic operations performed by the software, using debugging techniques. Main results. The model-based iterative reconstruction (MBIR) subprocedure (at the end of the software pipeline) and the Monte Carlo (MC) simulation (at the beginning) were piecewise differentiable. Jumps in the MBIR function arose from the discrete computation of the set of voxels intersected by a proton path. Jumps in the MC function likely arose from changes in the control flow that affect the amount of consumed random numbers. The tracking algorithm solves an inherently non-differentiable problem. Significance. The MC and MBIR codes are ready for the integration of AD, and further research on surrogate models for the tracking subprocedure is necessary.

    Comment: 27 pages, 11 figures
    Keywords Physics - Medical Physics ; Computer Science - Mathematical Software
    Subject code 000
    Publishing date 2022-02-11
    Publishing country us
    Document type Book ; Online
    Database BASE - Bielefeld Academic Search Engine (life sciences selection)

    More links

    Kategorien

To top