LIVIVO - The Search Portal for Life Sciences

zur deutschen Oberfläche wechseln
Advanced search

Search results

Result 1 - 10 of total 10

Search options

  1. Article ; Online: Outcomes of cystoid macular edema following Descemet’s membrane endothelial keratoplasty in a referral center for keratoplasty in Spain

    Nuno Moura-Coelho / Renato Papa-Vettorazzi / Imalvet Santiesteban-García / Arnaldo Dias-Santos / Felicidad Manero / João Paulo Cunha / José Güell

    Scientific Reports, Vol 13, Iss 1, Pp 1-

    retrospective study

    2023  Volume 9

    Abstract: Abstract The aim of this study was to analyze the outcomes of eyes with visually significant cystoid macular œdema (vs-CMO) after Descemet membrane endothelial keratoplasty (DMEK) in a referral center for keratoplasty in Spain. We conducted a ... ...

    Abstract Abstract The aim of this study was to analyze the outcomes of eyes with visually significant cystoid macular œdema (vs-CMO) after Descemet membrane endothelial keratoplasty (DMEK) in a referral center for keratoplasty in Spain. We conducted a retrospective, single-surgeon case series of eyes that developed post-DMEK vs-CMO performed between January 2011 and December 2020. Data collected included: indication for DMEK; biometric data; ocular comorbidities; past medical history; time to detection of vs-CMO after DMEK (T, weeks); best-corrected visual acuity (BCVA, logMAR) and central retinal thickness (CRT, µm) at diagnosis of vs-CMO, after resolution of CMO, and at last follow-up; and management strategy. Main outcomes analyzed were incidence of vs-CMO, improvement in BCVA and CRT after treatment of vs-CMO. Of 291 consecutive DMEK surgeries, 14 eyes of 13 patients (4.8%) developed vs-CMO. Five patients (38.5%) had history of CMO, and 28.6% of eyes had ophthalmic comorbidities. Median (P25-P75) T was 4 (3–10) weeks. Treatment success was observed in 12/13 eyes (92.3%), two of which required second-line treatment. In successful cases (median time-to-resolution 3.0 (2.0–3.5) months), median BCVA improved from 0.60 (0.40–0.80) logMAR to 0.30 (0.15–0.40) logMAR (p = 0.002) after treatment, and median CRT improved from 582.5 (400.0–655.0) µm to 278.0 (258.0–294.0) µm (p = 0.005). In our study, we found a 4.8% rate of post-DMEK vs-CMO, with most cases occurring in the first 3 months after surgery. Good functional and anatomical outcomes are expected in most eyes, without treatment-related complications or implications in graft outcomes. Additional studies are encouraged to determine a standardized protocol for post-DMEK vs-CMO.
    Keywords Medicine ; R ; Science ; Q
    Subject code 610
    Language English
    Publishing date 2023-02-01T00:00:00Z
    Publisher Nature Portfolio
    Document type Article ; Online
    Database BASE - Bielefeld Academic Search Engine (life sciences selection)

    More links

    Kategorien

  2. Article ; Online: Personalización de las constantes en las fórmulas de cálculo de la lente intraocular Personalization of constants in the intraocular lens calculation formulas

    Anneé Miranda Carracedo / Juan Raúl Hernández Silva / Imalvet Santiesteban García / Meisy Ramos López / Yanay Ramos Pereira / Carmen Padilla González

    Revista Cubana de Oftalmología, Vol 25, Iss 2, Pp 180-

    2012  Volume 191

    Abstract: Objetivo: personalizar las constantes A, factor cirujano y profundidad de la cámara anterior para las fórmulas de cálculo de la lente intraocular en la cirugía de catarata en el Instituto Cubano de Oftalmología "Ramón Pando Ferrer" de mayo de 2007 a ... ...

    Abstract Objetivo: personalizar las constantes A, factor cirujano y profundidad de la cámara anterior para las fórmulas de cálculo de la lente intraocular en la cirugía de catarata en el Instituto Cubano de Oftalmología "Ramón Pando Ferrer" de mayo de 2007 a enero de 2011. Métodos: se realizó un estudio descriptivo retrospectivo donde se estudiaron las constantes A, factor cirujano y profundidad de la cámara anterior. También se evaluó la longitud axial preoperatoria por IOL Master, la mejor agudeza visual sin corrección, el componente esférico esperado, el componente esférico obtenido y los resultados refractivos. Resultados: las constantes optimizadas por interferometría de coherencia parcial son diferentes a las propuestas por los fabricantes de las lentes intraoculares. Estas constantes personalizadas para cada cirujano no mostraron diferencias significativas. Las constantes optimizadas según las longitudes axiales, tienen diferencias significativas en los 3 grupos de estudio. La diferencia entre la lente intraocular implantada y la propuesta con las nuevas constantes resultó menor de 1 D de error en 83,1 % de los pacientes. El 75,4 % quedó bien corregido en relación con la diferencia entre la refracción esperada y la obtenida. Conclusiones: las constantes optimizadas por interferometría de coherencia parcial resultan más elevadas que las propuestas por el fabricante. La optimización de estas en el cálculo de la lente permite, de acuerdo a las características individuales de cada ojo (longitud axial), usar la fórmula adecuada e incrementa la predictibilidad de los resultados refractivos posoperatorios. Objective: to personalize the A, surgeon factor and anterior chamber depth constants for intraocular lens calculation formulas in the cataract surgery at the “Ramón Pando Ferrer” Cuban Ophthalmological Institute from May 2007 to January 2011. Method: a retrospective and descriptive study was made to study the A constant, the surgeon factor and the anterior chamber depth. Additionally, the preoperative axial length was evaluated by IOL Master, as well as the best uncorrected visual acuity, the expected and the obtained spherical component, and the refractive results. Results: the constants optimized by the partial coherence interferometry were different from those suggested by the intraocular lens manufacturers. These customized constants for each surgeon did not show significant differences among them. The optimized constants according to the axial lengths showed significant differences in the three study groups. The difference between the implanted lens and the estimated lens based on the new constants was lower than one dioptre of error in 83.1 % of patients. Good visual correction in relation with the difference between the expected and the final refractions was attained in 75.4 % of patients. Conclusions: the partial coherence interferometry-optimized constants showed higher values than those suggested by the manufacturer. The constant optimization for the intraocular lens calculation by IOL Master allows, according to the ocular individual features (axial length), using the adequate formula and increasing the predictability of postoperative refractive results.
    Keywords cálculo de la lente intraocular ; IOL Master ; constante A ; factor cirujano ; profundidad de la cámara anterior ; intraocular lens calculation ; A constant ; surgeon factor ; anterior chamber depth ; Ophthalmology ; RE1-994 ; Medicine ; R ; DOAJ:Ophthalmology ; DOAJ:Medicine (General) ; DOAJ:Health Sciences
    Language Spanish
    Publishing date 2012-12-01T00:00:00Z
    Publisher Editorial Ciencias Médicas
    Document type Article ; Online
    Database BASE - Bielefeld Academic Search Engine (life sciences selection)

    More links

    Kategorien

  3. Article ; Online: Resultados del implante múltiple de lentes intraoculares en la cirugía de catarata en el Instituto Cubano de Oftalmología "Ramón Pando Ferrer" Results of the multiple intraocular lenses implantation in the cataract surgery performed at "Ramón Pando Ferrer" Cuban Institute of Ophthalmology

    Eric Montero Díaz / Armando Capote Cabrera / Eneida Pérez Candelaria / Imalvet Santiesteban García / Alina Pedroso Llanes / Belkys Rodríguez Suárez

    Revista Cubana de Oftalmología, Vol 23, Iss 1, Pp 78-

    2010  Volume 87

    Abstract: OBJETIVO: Valorar los resultados visuales de los pacientes operados con la técnica de piggy back o implantes múltiples de lentes intraoculares. MÉTODOS: Se realizó un estudio descriptivo retrospectivo de corte transversal en el que se tomaron 32 ojos de ... ...

    Abstract OBJETIVO: Valorar los resultados visuales de los pacientes operados con la técnica de piggy back o implantes múltiples de lentes intraoculares. MÉTODOS: Se realizó un estudio descriptivo retrospectivo de corte transversal en el que se tomaron 32 ojos de 30 pacientes del universo operado de catarata, con la técnica antes descrita, en el Instituto Cubano de Oftalmología "Ramón Pando Ferrer", en el período comprendido entre enero de 2000 hasta diciembre de 2006. Fueron evaluadas algunas variables demográficas, como edad y sexo, así como agudeza visual y refracción preoperatorio y posoperatoria con cristales y sin ellos. Reportamos las complicaciones transquirúrgicas y posquirúrgicas asociadas a las diferentes técnicas quirúrgicas empleadas para la extracción del cristalino. RESULTADOS: La edad promedio obtenida fue mayor de 50 años, y predominó el sexo femenino. Parte de los pacientes tuvieron una agudeza visual corregida superior a 20/40. La complicación más frecuente fue la opacidad de la cápsula posterior y solo en la tercera parte de los pacientes se obtuvo una buena corrección refractiva. CONCLUSIONES: La técnica de piggy back permitió la recuperación de cuatro líneas en la cartilla de Snellen en la agudeza visual corregida, mientras que en la agudeza visual sin corrección solo aumentó en dos líneas. Se encontró igual número de pacientes hipocorregidos y bien corregidos. OBJECTIVE: To asses the visual results of patients operated on by piggy back technique or multiple implantation of intraocular lenses METHODS: A retrospective cross-sectional descriptive study was conducted in 32 eyes from 30 patients operated on from cataract, using the above-mentioned technique, at "Ramon Pando Ferrer" Cuban Institute of Ophthalmology in the period January 2000 through December 2006. Some demographic variables as age and sex as well as visual acuity and preoperative and postoperative refraction with/without lenses were evaluated. Trans-surgical and post-surgical complications associated with the various surgical techniques for the crystalline extraction were reported. RESULTS: Average age was 50 years, being the females predominant. One part of the patients had corrected visual acuity over 20/40. The most frequent complication was posterior capsule opacity and only one third of patients showed good refractive correction. CONCLUSIONS: Piggy back technique allowed recovering four lines in corrected visual acuity in Snellen´s chart whereas uncorrected visual acuity increased two lines only. The number of hypocorrected and well-corrected patients was the same.
    Keywords Piggy back ; sorpresa refractiva ; equivalente esférico ; refractive surprise ; spheral equivalent ; Ophthalmology ; RE1-994 ; Medicine ; R ; DOAJ:Ophthalmology ; DOAJ:Medicine (General) ; DOAJ:Health Sciences
    Language Spanish
    Publishing date 2010-06-01T00:00:00Z
    Publisher Editorial Ciencias Médicas
    Document type Article ; Online
    Database BASE - Bielefeld Academic Search Engine (life sciences selection)

    More links

    Kategorien

  4. Article ; Online: Efectividad del cálculo del poder dióptrico de la lente intraocular con interferometría parcialmente coherente Effectiveness of the intraocular lens power calculation using the partial coherent interferometry

    Imalvet Santiesteban García / Eneida Pérez Candelaria / Armando Capote Cabrera / Eric Montero Díaz / Alina Pedroso Llanes / Belkys Rodríguez Suárez

    Revista Cubana de Oftalmología, Vol 23, Iss 1, Pp 88-

    2010  Volume 99

    Abstract: OBJETIVO: Comparar la efectividad del cálculo del poder dióptrico de la lente intraocular con IOL Master y el método de biometría por aplanación convencional. MÉTODOS: Se seleccionó una muestra de 100 ojos (pacientes) mediante un muestreo simple ... ...

    Abstract OBJETIVO: Comparar la efectividad del cálculo del poder dióptrico de la lente intraocular con IOL Master y el método de biometría por aplanación convencional. MÉTODOS: Se seleccionó una muestra de 100 ojos (pacientes) mediante un muestreo simple aleatorio, en el Servicio de Catarata del Centro de Microcirugía Ocular, con diagnóstico de catarata unilateral o bilateral en la consulta preoperatorio, desde marzo hasta septiembre de 2006. Se clasificaron en dos grupos según el método utilizado para el cálculo de la lente intraocular. Se analizaron las variables: longitud axial media preoperatoria, promedio queratométrico preoperatorio, componente esférico esperado y obtenido, agudeza visual sin corrección y mejor agudeza visual corregida preoperatoria y posoperatoria. El análisis estadístico de los resultados se realizó mediante un análisis de varianza, la prueba t de Student de comparación de medias para datos pareados y chi cuadrado. Se utilizó un nivel de confiabilidad de 95 %. RESULTADOS: Entre los principales resultados se encontró que la diferencia de las longitudes axiales entre los métodos IOL Master y biometría por aplanación A-Scan fue estadísticamente significativa. La agudeza visual sin corrección aumentó cuatro líneas y la mejor agudeza visual corregida seis líneas en el posoperatorio de los pacientes del grupo I. El 90 % de los pacientes del grupo I, o sea, los calculados con IOL Master quedaron en la emetropía en cuanto al componente esférico. CONCLUSIONES: Se evidenció una diferencia significativa e inferior a la encontrada en estudios internacionales entre las longitudes axiales preoperatorias halladas mediante los métodos IOL Master y biometría por aplanación; resultaron superiores las calculadas por IOL Master. Se obtuvo ganancia en las líneas de la Cartilla de Snellen tanto de la agudeza visual sin corrección como la mejor agudeza visual corregida en ambos grupos (superior en el grupo II). Predomina ron los resultados refractivos con tendencia a la emetropía teniendo en cuenta el componente esférico obtenido en ambos grupos, los cuales también fueron superiores en el grupo I. OBJECTIVE: to compare the effectiveness of the intraocular lens dioptric power calculation using IOL Master and the conventional applanation biometry. METHODS: A sample of 100 eyes (patients), diagnosed with unilateral or bilateral cataract in the preoperative consultation service, was selected through simple random sampling in the Ocular Microsurgery Center in the period from March to September, 2006. They were divided into two groups based on the method for intraocular lens calculation. The variables were preoperative mean axial length, preoperative keratometric average, expected and obtained spheral component, visual acuity without correction and better corrected visual acuity preoperatively and postoperatively. The statistical analysis of the results was made by variance analysis, Student's t test for paired mean comparisons and Chi square. The confidence level of 95 % was used. RESULTS: Among the main results, it was found that the axial length differences between IOL Master and A-Scan applanation biometry was statistically significant. Visual acuity without correction increased 4 lines and the best corrected visual acuity increased 6 lines in the postoperative period of the group I patients. Ninety percent of the group I patients, whose visual acuity was calculated with IOL Master, reached emetropia in terms of the spheral component. CONCLUSIONS: A significant difference but lower than that found in the international studies among the preoperative axial lengths calculated through ILO Master and applanation biometry were evinced. The differences were higher in the lenghts calculated by IOL Master. There was improvement in the number of lines of Snellen´s chart both in the visual acuity without correction and the better corrected visual acuity in the two groups; being better in group II. The refractive results tending to emetropy prevailed, taking into consideration the spheral component reached in both groups, which were also higher in group I.
    Keywords Interferometría parcialmente coherente ; biometría por contacto ; Partial coherence interferometry ; contact biometry ; Ophthalmology ; RE1-994 ; Medicine ; R ; DOAJ:Ophthalmology ; DOAJ:Medicine (General) ; DOAJ:Health Sciences
    Language Spanish
    Publishing date 2010-06-01T00:00:00Z
    Publisher Editorial Ciencias Médicas
    Document type Article ; Online
    Database BASE - Bielefeld Academic Search Engine (life sciences selection)

    More links

    Kategorien

  5. Article ; Online: Utilidad del Pentacam para medir el poder corneal después de cirugía refractiva con excímer láser Use of Pentacam camera in measuring the corneal power after Excimer laser refractive surgery

    Yoriel Cuan Aguilar / Eneida de la C Pérez Candelaria / Eric Montero Díaz / Imalvet Santiesteban García / Lorelei Ortega Díaz / Taimí Cárdenas Díaz

    Revista Cubana de Oftalmología, Vol 23, Pp 513-

    2010  Volume 521

    Abstract: OBJETIVO: Evaluar el poder corneal brindado por el Pentacam en pacientes miopes operados de cirugía refractiva con excimer láser en el Instituto Cubano de Oftalmología «Ramón Pando Ferrer», desde septiembre a diciembre de 2008. MÉTODOS: Se realizó un ... ...

    Abstract OBJETIVO: Evaluar el poder corneal brindado por el Pentacam en pacientes miopes operados de cirugía refractiva con excimer láser en el Instituto Cubano de Oftalmología «Ramón Pando Ferrer», desde septiembre a diciembre de 2008. MÉTODOS: Se realizó un estudio prospectivo en 50 ojos de 25 pacientes, utilizando varias mediciones obtenidas por el Pentacam: mapas de color queratométrico total y Equivalent K-reading Power, el true net power y las lecturas de queratometría equivalentes a diferentes diámetros. Todas analizadas y comparadas con los valores de queratometrías obtenidos a través del método de historia clínica. Además se compararon las queratometrías preoperatorias reales con las queratometrías preoperatorias estimadas mostradas por el Pentacam. El análisis estadístico se realizó con la Prueba T para datos pareados, utilizando una significación del 95%. RESULTADOS: No hubo diferencias estadísticas significativas entre las queratometrías del método de historia clínica, el Equivalent K-reading Power y las lecturas de queratometría equivalentes a diferentes diámetros, mostrando la de 3,0 mm, la menor diferencia. El resto de las mediciones difirieron de forma significativa. No se encontró diferencias entre las queratometrías preoperatorios. CONCLUSIONES: El Pentacam aportó poderes corneales que no difirieron estadísticamente de los obtenidos por el método de historia clínica en ojos miopes que tenían cirugía previa con excímer láser. OBJECTIVE: To evaluate the corneal power offered by Pentacam for myopic patients operated on by refractive excimer laser surgery at "Ramón Pando Ferrer" Cuban Institute of Ophthalmology from September to December, 2008. METHODS: A prospective study was performed in 50 eyes of 25 patients, using several measurements taken by Pentacam: total keratometric color maps and Equivalent K-reading Power, true net power and the keratometry readings equivalent to different diameters. All these measurements were analyzed and compared with the keratometry values seen in the clinical records. The real preoperative keratometries were also compared with the estimated preoperative keratometries shown by the Pentacam. The statistical analysis was based on paired t test, with 95 % significance. RESULTS: There were not significant statistical differences among the Keratometries of the medical histories, the Equivalent K-reading Power and the Keratometry readings equivalent to different diameters, being the 3.0 mm reading the one that showed the smallest difference. The rest of the measurements significantly differed. There were no differences among the preoperative keratometries. CONCLUSIONS: The Pentacam camera provided corneal powers that did not differ statistically from those found in the medical history in the myopic eyes that had previously undergone Excimer laser surgery.
    Keywords Poder corneal ; queratometría ; cirugía refractiva ; excímer láser ; Corneal power ; Keratometry ; refractive surgery ; Excimer laser ; Ophthalmology ; RE1-994 ; Medicine ; R ; DOAJ:Ophthalmology ; DOAJ:Medicine (General) ; DOAJ:Health Sciences
    Language Spanish
    Publishing date 2010-01-01T00:00:00Z
    Publisher Editorial Ciencias Médicas
    Document type Article ; Online
    Database BASE - Bielefeld Academic Search Engine (life sciences selection)

    More links

    Kategorien

  6. Article ; Online: Actualización en el tratamiento médico del glaucoma pediátrico

    Yanileidy Blanco González / Teresita de Jesús Méndez Sánchez / Haymy Casanuevas Cabeza / Daniel López Felipe / Imalvet Santiesteban García / Teresa Arronte Alarcón

    Revista Cubana de Oftalmología, Vol 26, Iss suppl 1, Pp 605-614

    Abstract: En la actualidad no existen suficientes estudios para valorar la seguridad y eficacia de los medicamentos hipotensivos oculares en el glaucoma pediátrico. El uso de medicamentos para reducir la presión intraocular en niños, se considera desacertado ... ...

    Abstract En la actualidad no existen suficientes estudios para valorar la seguridad y eficacia de los medicamentos hipotensivos oculares en el glaucoma pediátrico. El uso de medicamentos para reducir la presión intraocular en niños, se considera desacertado principalmente en glaucomas congénitos primarios y en los asociados a anomalías oculares. En otros tipos de glaucomas, como los juveniles no asociados a goniodisgenesias y secundarios, se suele comenzar con tratamiento medicamentoso, aunque por los efectos adversos de este y el no control adecuado de la tensión ocular, un porcentaje importante necesita tratamiento quirúrgico. Se realiza una revisión bibliográfica actualizada con el objetivo de describir el mecanismo de acción, dosificación y efectos indeseables de los medicamentos hipotensores oculares en niños con glaucoma.
    Keywords medical treatment ; adverse effects ; congenital glaucoma ; Ophthalmology ; RE1-994 ; Medicine ; R
    Language Spanish
    Publisher Editorial Ciencias Médicas
    Document type Article ; Online
    Database BASE - Bielefeld Academic Search Engine (life sciences selection)

    More links

    Kategorien

  7. Article ; Online: Lentes fáquicos como alternativa de tratamiento en el queratocono

    Raúl Barroso Lorenzo / Imalvet Santiesteban García / Iramis Miranda Hernández / Madelyn Jareño Ochoa / Luis Curbelo Cunill / Ledia Perea Hevia

    Revista Cubana de Oftalmología, Vol 27, Iss 2, Pp 237-245

    Abstract: El queratocono es una enfermedad degenerativa que se caracteriza por un adelgazamiento progresivo del estroma corneal y la deformidad en forma de cono de la córnea, lo cual provoca astigmatismo irregular y miopía elevada. Se realizó una revisión de ... ...

    Abstract El queratocono es una enfermedad degenerativa que se caracteriza por un adelgazamiento progresivo del estroma corneal y la deformidad en forma de cono de la córnea, lo cual provoca astigmatismo irregular y miopía elevada. Se realizó una revisión de artículos publicados referentes al implante de lentes intraoculares fáquicos como alternativa de tratamiento en esta entidad, la cual continúa siendo de difícil manejo en la actualidad. En ametropías con alto componente esférico y cilíndrico, el uso de lente fáquico tórico mostró óptimos resultados visuales. De igual modo el uso de lentes de soporte angular "estira" la córnea y achata el área apical central a través de sus hápticas, con lo que reduce la ectasia corneal y el astigmatismo irregular asimétrico. A su vez, la presencia del lente intraocular entre la pupila y la córnea crea una barrera física que evita la acción de la corriente de humor acuoso contra la córnea y, por consiguiente, hay una estabilización de todos los parámetros de la córnea después de la implantación del lente. La literatura reporta combinación de implantes de lentes fáquicos posterior a anillos intraestromales y crosslinking con un excelente resultado funcional: incrementa en forma importante la agudeza visual sin corrección, mejora las topografías corneales y las aberraciones de alto orden y disminuye la posibilidad de requerir un trasplante de córnea. El uso de lentes fáquicos tóricos en queratoconos estables es una alternativa terapéutica válida como tratamiento de la ametropía que acompaña a esta patología.
    Keywords keratoconus ; phakic lenses ; ametropia ; Ophthalmology ; RE1-994 ; Medicine ; R
    Language Spanish
    Publisher Editorial Ciencias Médicas
    Document type Article ; Online
    Database BASE - Bielefeld Academic Search Engine (life sciences selection)

    More links

    Kategorien

  8. Article ; Online: Cirugía de cataratas por facoemulsificación aplicando la técnica de prechop

    Belkys Rodríguez Suárez / Juan Raúl Hernández Silva / Eneida de la Caridad Pérez Candelaria / Ana María Méndez Duque de Estrada / Iraisi Hormigó Puertas / Imalvet Santiesteban García

    Revista Cubana de Oftalmología, Vol 26, Iss 1, Pp 30-38

    Abstract: Objetivos: aplicar la técnica de prechop en la cirugía de catarata por facoemulsificación y describir sus resultados. Métodos: estudio descriptivo y prospectivo en 295 pacientes (ojos) con diagnóstico de catarata senil atendidos en el Instituto Cubano de ...

    Abstract Objetivos: aplicar la técnica de prechop en la cirugía de catarata por facoemulsificación y describir sus resultados. Métodos: estudio descriptivo y prospectivo en 295 pacientes (ojos) con diagnóstico de catarata senil atendidos en el Instituto Cubano de Oftalmología "Ramón Pando Ferrer", entre enero y diciembre de 2010. Se analizaronlas variables: mejor agudeza visual corregida y sin corregir, conteo celular endotelial, hexagonalidad, coeficiente de variabilidad, astigmatismo resultante, tiempo efectivo de ultrasonido y complicaciones. Resultados: la pérdida celular endotelial fue de 14,2 %. La hexagonalidad promedio posoperatoria, de 50,99 %. El coeficiente de variabilidad promedio preoperatorio fue de 32,37 % y cambió a 30,43 % en el posoperatorio. El astigmatismo posoperatorio promedio fue de 1,48 dioptría con una inducción de 0,51 dioptría. El tiempo efectivo de ultrasonido estuvo por debajo de los 2 minutos en el 80 % de los casos. La mejor agudeza visual sin corregir preoperatoria fue de 0,14 como promedio y mejoró a 0,43 en el posoperatorio, mientras que la mejor agudeza visual corregida, de 0,29 en el preoperatorio mejoró a 0,82. La complicación transquirúrgica más frecuente fue la rotura de la cápsula posterior y la posquirúrgica, el edema corneal. Conclusiones: la opción de realizar la técnica de prechop para emulsificar el cristalino representa una ventaja para la cirugía de cataratas, sobre todo en pacientes con cristalinos duros por la poca repercusión para el endotelio corneal. Existe una mejoría importante de la agudeza visual sin corregir y con corrección después de la cirugía.
    Keywords cataract ; prechop phacoemulsification ; endothelial cellular loss ; astigmatism ; Ophthalmology ; RE1-994 ; Medicine ; R
    Language Spanish
    Publisher Editorial Ciencias Médicas
    Document type Article ; Online
    Database BASE - Bielefeld Academic Search Engine (life sciences selection)

    More links

    Kategorien

  9. Article ; Online: Facochop en la facopremium

    Juan Raúl Hernández Silva / Marcelino Rio Torres / Meisy Ramos López / Luis Curbelo Cunill / Yanay Ramos Pereira / Imalvet Santiesteban Garcia / Anneé Miranda Carracedo / Marietta Gutiérrez Castillo / Heidy Hernández Ramos

    Revista Cubana de Oftalmología, Vol 27, Iss 2, Pp 246-252

    Abstract: La cirugía de catarata se ha convertido en Oftalmología en uno de los procedimientos quirúrgicos de excelencia tanto en su planificación, como en sus resultados. En la facoemulsificación premium hay que tener una estrecha comunicación con el paciente, ... ...

    Abstract La cirugía de catarata se ha convertido en Oftalmología en uno de los procedimientos quirúrgicos de excelencia tanto en su planificación, como en sus resultados. En la facoemulsificación premium hay que tener una estrecha comunicación con el paciente, para conocer sus necesidades visuales y planificar adecuadamente la cirugía. Se analizan los aspectos fundamentales del proceder desde el examen oftalmológico inicial, los cálculos biométricos, la lente intraocular más apropiada, así como las máquinas de facoemulsificación que se utilizarán en la cirugía para permitir resultados óptimos y controlados.
    Keywords cataract ; intraocular lens ; phacoemulsification ; premiun ; Ophthalmology ; RE1-994 ; Medicine ; R
    Language Spanish
    Publisher Editorial Ciencias Médicas
    Document type Article ; Online
    Database BASE - Bielefeld Academic Search Engine (life sciences selection)

    More links

    Kategorien

  10. Article ; Online: Correlación de los valores queratométricos del Pentacam y el método de Maloney

    Eneida de la Caridad Pérez Candelaria / Taimi Cárdenas Díaz / Iraisi Hormigó Puertas / Elier Alarcón González / Katia Trujillo Fonseca / Imalvet Santiesteban García

    Revista Cubana de Oftalmología, Pp 432-443

    Keywords Pentacam ; cataract surgery ; radial keratotomy ; Ophthalmology ; RE1-994 ; Medicine ; R
    Language Spanish
    Publisher Editorial Ciencias Médicas
    Document type Article ; Online
    Database BASE - Bielefeld Academic Search Engine (life sciences selection)

    More links

    Kategorien

To top