LIVIVO - The Search Portal for Life Sciences

zur deutschen Oberfläche wechseln
Advanced search

Search results

Result 1 - 3 of total 3

Search options

  1. Article ; Online: The Changed Route of Anterior Tibial Artery due to Healed Fracture

    Kemal Gökkuş / Ergin Sagtas / Nuri Comert / Mehmet Bekir Unal / Murat Baloglu

    Case Reports in Vascular Medicine, Vol

    2016  Volume 2016

    Abstract: We would like to highlight unusual sequelae of healed distal third diaphyseal tibia fracture that was treated conservatively 36 years ago, in which we incidentally detected peripheral CT angiography. The anterior tibial artery was enveloped three- ... ...

    Abstract We would like to highlight unusual sequelae of healed distal third diaphyseal tibia fracture that was treated conservatively 36 years ago, in which we incidentally detected peripheral CT angiography. The anterior tibial artery was enveloped three-quarterly by the healing callus of the bone (distal tibia).
    Keywords Internal medicine ; RC31-1245 ; Diseases of the circulatory (Cardiovascular) system ; RC666-701
    Language English
    Publishing date 2016-01-01T00:00:00Z
    Publisher Hindawi Publishing Corporation
    Document type Article ; Online
    Database BASE - Bielefeld Academic Search Engine (life sciences selection)

    More links

    Kategorien

  2. Article ; Online: Comparing Dimensions of Four-Strand Hamstring Tendon Grafts with Native Anterior and Posterior Cruciate Ligaments

    Barış Yılmaz / Güzelali Özdemir / Elif N. Keskinöz / Gamze Tümentemur / Kemal Gökkuş / Bahtiyar Demiralp

    BioMed Research International, Vol

    2016  Volume 2016

    Abstract: Background. The aim of the study was to evaluate whether or not there was any incompatibility between four-strand hamstring tendons taken from the same knee and the dimensions of the ACL and PCL. Methods. 15 fresh frozen cadaver hamstrings were prepared ... ...

    Abstract Background. The aim of the study was to evaluate whether or not there was any incompatibility between four-strand hamstring tendons taken from the same knee and the dimensions of the ACL and PCL. Methods. 15 fresh frozen cadaver hamstrings were prepared as four-strand grafts and measurements made of the ACL and PCL circumferences in the midsection were made in the narrowest part of the midsection. The cross-section areas and diameters were calculated with geometric calculations used to measure the cross-sectional area of cylinders. Accepting that the geometric insertions were elliptical, the length, width, and area were calculated for entry areas. Results. A significant relationship at 96.2% was determined between the ACL mid and the hamstring diameter. A significant relationship at 96.7% was determined between the ACL and the hamstring mid area. A significant relationship at 96.4% was determined between the PCL mid and the hamstring diameter. A significant relationship at 95.7% was determined between the PCL and the hamstring mid area. Conclusion. For the reconstruction of ACL and PCL, it was determined that there is less incompatibility between the four-strand hamstring tendons taken from the same knee and the dimensions of the midsection PCL compared to the ACL dimensions.
    Keywords Medicine ; R
    Subject code 796
    Language English
    Publishing date 2016-01-01T00:00:00Z
    Publisher Hindawi Limited
    Document type Article ; Online
    Database BASE - Bielefeld Academic Search Engine (life sciences selection)

    More links

    Kategorien

  3. Article ; Online: Luxatio erecta humeri

    Kemal Gökkus / Ergin Sagtas / Murat Saylik / Ahmet Turan Aydin / Halil Atmaca

    Journal of Emergencies, Trauma and Shock, Vol 8, Iss 1, Pp 43-

    Report of a swimming injury with analysis of the mechanism of the injury and associated injuries in literature

    2015  Volume 48

    Abstract: Inferior shoulder dislocation also referred to as luxatio erecta is an unusual and rare type of shoulder dislocation. Its incidence is about 0.5% among all shoulder dislocations. After an exhaustive search of all the available literature we were unable ... ...

    Abstract Inferior shoulder dislocation also referred to as luxatio erecta is an unusual and rare type of shoulder dislocation. Its incidence is about 0.5% among all shoulder dislocations. After an exhaustive search of all the available literature we were unable to find a swimming accident case that did not have other associated injuries and an uneventful reduction. The mechanism of the injury was mostly related to direct axial loading and indirect hyperabduction lever arm. We would like to emphasize the importance of this being a swimming accident, a type of accident that requires awareness of the possibility of dangerous asphyxia injuries caused by panic in the water (swimming pool, river, lake, sea, etc.). We described the nature of the injury and review the literature concerning the mechanism of the injury and associated neurovascular impairment at admission time. We also presented a supplemental video to contribute to the education of young residents and orthopedic surgeons.
    Keywords Dislocation ; inferior shoulder dislocation ; shoulder ; swimming injury ; Medical emergencies. Critical care. Intensive care. First aid ; RC86-88.9 ; Internal medicine ; RC31-1245 ; Medicine ; R
    Language English
    Publishing date 2015-01-01T00:00:00Z
    Publisher Medknow Publications
    Document type Article ; Online
    Database BASE - Bielefeld Academic Search Engine (life sciences selection)

    More links

    Kategorien

To top