LIVIVO - The Search Portal for Life Sciences

zur deutschen Oberfläche wechseln
Advanced search

Search results

Result 1 - 10 of total 32

Search options

  1. Article ; Online: Editorial

    Nicola Rosa / Gilda Cennamo / Maddalena De Bernardo

    Frontiers in Medicine, Vol

    Ocular ultrasonography and optical coherence tomography in the optic nerve disease

    2023  Volume 10

    Keywords OCT ; optic nerve ; ultrasound ; papilledema ; optic disc drusen ; intracranial hypertension ; Medicine (General) ; R5-920
    Language English
    Publishing date 2023-02-01T00:00:00Z
    Publisher Frontiers Media S.A.
    Document type Article ; Online
    Database BASE - Bielefeld Academic Search Engine (life sciences selection)

    More links

    Kategorien

  2. Article ; Online: Editorial

    Luigi Capasso / Maddalena De Bernardo / Maria Borrelli

    Frontiers in Medicine, Vol

    Corneal disease: an update

    2023  Volume 10

    Keywords cornea ; external disease ; refractive surgery ; keratoconjunctivitis ; keratoconus ; Medicine (General) ; R5-920
    Language English
    Publishing date 2023-04-01T00:00:00Z
    Publisher Frontiers Media S.A.
    Document type Article ; Online
    Database BASE - Bielefeld Academic Search Engine (life sciences selection)

    More links

    Kategorien

  3. Article ; Online: Editorial

    Livio Vitiello / Maddalena De Bernardo / Palmiro Cornetta

    Frontiers in Medicine, Vol

    Optical coherence tomography and OCT angiography examination in systemic diseases

    2023  Volume 10

    Keywords OCT ; optical coherence tomography ; systemic disease ; OCT angiography ; OCTA ; Medicine (General) ; R5-920
    Language English
    Publishing date 2023-02-01T00:00:00Z
    Publisher Frontiers Media S.A.
    Document type Article ; Online
    Database BASE - Bielefeld Academic Search Engine (life sciences selection)

    More links

    Kategorien

  4. Article ; Online: Comment on Iida et al. Development of a New Method for Calculating Intraocular Lens Power after Myopic Laser In Situ Keratomileusis by Combining the Anterior–Posterior Ratio of the Corneal Radius of the Curvature with the Double-K Method. J. Clin. Med. 2022, 11 , 522

    Ferdinando Cione / Maddalena De Bernardo / Nicola Rosa

    Journal of Clinical Medicine, Vol 11, Iss 1996, p

    2022  Volume 1996

    Abstract: We read with great interest the article by Iida et al. [.] ...

    Abstract We read with great interest the article by Iida et al. [.]
    Keywords n/a ; Medicine ; R
    Language English
    Publishing date 2022-04-01T00:00:00Z
    Publisher MDPI AG
    Document type Article ; Online
    Database BASE - Bielefeld Academic Search Engine (life sciences selection)

    More links

    Kategorien

  5. Article ; Online: Correspondence

    Maddalena De Bernardo / Nicola Rosa

    Journal of Clinical and Diagnostic Research, Vol 12, Iss 3, p NL

    Comparison of Central Corneal Thickness using Anterior Segment Optical Coherence Tomography Versus Ultrasound Pachymetry

    2018  Volume 01

    Keywords Medicine ; R
    Language English
    Publishing date 2018-03-01T00:00:00Z
    Publisher JCDR Research and Publications Private Limited
    Document type Article ; Online
    Database BASE - Bielefeld Academic Search Engine (life sciences selection)

    More links

    Kategorien

  6. Article ; Online: Comment on “Optic Nerve Sheath Diameter Ultrasound Evaluation in Intensive Care Unit

    Maddalena De Bernardo / Nicola Rosa

    BioMed Research International, Vol

    Possible Role and Clinical Aspects in Neurological Critical Patients’ Daily Monitoring”

    2018  Volume 2018

    Keywords Medicine ; R
    Language English
    Publishing date 2018-01-01T00:00:00Z
    Publisher Hindawi Limited
    Document type Article ; Online
    Database BASE - Bielefeld Academic Search Engine (life sciences selection)

    More links

    Kategorien

  7. Article ; Online: Comparison between dynamic contour tonometry and Goldmann applanation tonometry correcting equations

    Maddalena De Bernardo / Claudia Casaburi / Ilaria De Pascale / Luigi Capasso / Ferdinando Cione / Nicola Rosa

    Scientific Reports, Vol 12, Iss 1, Pp 1-

    2022  Volume 11

    Abstract: Abstract In order to investigate the reliability of correcting GAT formulas in comparison with dynamic contour tonometry (DCT), this study included 112 right eyes of 112 healthy subjects aged from 21 to 77 years, whose eyes underwent to a full ... ...

    Abstract Abstract In order to investigate the reliability of correcting GAT formulas in comparison with dynamic contour tonometry (DCT), this study included 112 right eyes of 112 healthy subjects aged from 21 to 77 years, whose eyes underwent to a full ophthalmologic exam. IOP was measured in each eye with DCT and then with GAT. IOP values obtained with GAT were corrected with 10 equations and then compared with those provided by DCT. Participants mean age was 42.24 ± 14.08 years; mean IOP measured with DCT was 17.61 ± 2.87 and 15.50 ± 2.47 mmHg, measured with GAT. The mean discordance between DCT and GAT measurements was 2.11 ± 2.24 mmHg. All the correcting formulas, but Srodka one (p ˂ 0.001), tend to increase the difference between GAT and DCT. According to these results Śródka equation provides the best correction, reducing the difference between the two IOP measurement methods of − 0.03 ± 0.85 mmHg. Other equations do not provide a valid improvement of the agreement between the two methods or they provide a worsening of the agreement.
    Keywords Medicine ; R ; Science ; Q
    Subject code 518
    Language English
    Publishing date 2022-11-01T00:00:00Z
    Publisher Nature Portfolio
    Document type Article ; Online
    Database BASE - Bielefeld Academic Search Engine (life sciences selection)

    More links

    Kategorien

  8. Article ; Online: Intraocular Pressure Measurements in Standing, Sitting, and Supine Position

    Maddalena De Bernardo / Giulia Abbinante / Maria Borrelli / Margherita Di Stasi / Ferdinando Cione / Nicola Rosa

    Journal of Clinical Medicine, Vol 11, Iss 6234, p

    Comparison between Tono-Pen Avia and Icare Pro Tonometers

    2022  Volume 6234

    Abstract: Background: Intraocular pressure (IOP) is influenced by body position. The purpose of this study is to compare the IOP measurements obtained with two different devices, to investigate IOP changes in standing, sitting, and supine positions. Methods: In ... ...

    Abstract Background: Intraocular pressure (IOP) is influenced by body position. The purpose of this study is to compare the IOP measurements obtained with two different devices, to investigate IOP changes in standing, sitting, and supine positions. Methods: In this comparative prospective case series, IOP was measured in sitting, supine, prone, and standing (standing 1) positions and again five minutes after standing (standing 2), utilizing an Icare Pro (ICP) and a Tono-Pen Avia (TPA) in the 64 eyes of 32 healthy subjects. Results: Compared to the sitting position, both devices showed an increase in the IOP both in supine and standing 2 positions ( p < 0.05). The mean IOP difference between the two devices was: in the sitting position, 0.57 ± 2.10 mmHg (range: −3.80 to 6.60 mmHg) ( p < 0.05), in the supine position, 0.93 ± 2.49 mmHg (range: −4.50 to 7.10 mmHg) ( p < 0.05), in the standing 1 position, 0.37 ± 1.96 mmHg (range: −5.20 to 5.00 mmHg) ( p = 0.102), and in the standing 2 position 0.73 ± 2.03 mmHg (range: −4.5 to 6.4 mmHg) ( p < 0.001). Conclusions: The results highlight an agreement between the TPA and ICP, both confirming not only the increase in IOP in the supine position, but also showing an increase in the standing 2 position. Therefore, it is suggested to perform such measurements in patients with glaucoma, to explain its progression in an apparently normal tension or in compensated patients.
    Keywords intraocular pressure ; Icare Pro ; standing position ; supine position ; Tono-Pen Avia ; Medicine ; R
    Language English
    Publishing date 2022-10-01T00:00:00Z
    Publisher MDPI AG
    Document type Article ; Online
    Database BASE - Bielefeld Academic Search Engine (life sciences selection)

    More links

    Kategorien

  9. Article ; Online: A formula to improve the reliability of optical axial length measurement in IOL power calculation

    Maddalena De Bernardo / Ferdinando Cione / Luigi Capasso / Alessia Coppola / Nicola Rosa

    Scientific Reports, Vol 12, Iss 1, Pp 1-

    2022  Volume 8

    Abstract: Abstract To verify the influence of axial length (AL) variations after cataract surgery in IOL power calculation. Patients underwent ophthalmic evaluation before surgery, including optical biometry with IOLMaster 500. Same exams were repeated 2 months ... ...

    Abstract Abstract To verify the influence of axial length (AL) variations after cataract surgery in IOL power calculation. Patients underwent ophthalmic evaluation before surgery, including optical biometry with IOLMaster 500. Same exams were repeated 2 months after surgery: AL of operated eye was evaluated using two modes (pseudophakic/aphakic options). Mean Keratometry and AL changes were analyzed. Furthermore, refractive prediction error (PE) was back-calculated with Barrett Universal-II, Hoffer-Q, Holladay-1 and SRK/T formulas. To eliminate any systematic error, the mean error (ME) was zeroed-out for each formula. MEs and median absolute errors (MedAEs) of PEs were analyzed. Two-hundred-one operated eyes of 201 patients and 201 opposite eyes were evaluated. In operated eyes, mean AL difference was − 0.11 ± 0.07 mm (p < 0.001) with pseudophakic option and 0.00 ± 0.07 mm (p = 0.922) with aphakic option. There were not-statistically significant differences between MedAE of PEs calculated after zeroing-out the ME with different ALs (p > 0.05). Instead, only MEs of PEs obtained with postoperative ALs-pseudophakic option were not-statistically different from zero (p > 0.05). AL measurement change after cataract surgery is probably due to a systematic error in optical biometer in case of phakic eyes. A correction factor applied to preoperative AL could eliminate any systematic error in IOL power calculation without modifying the lens constant.
    Keywords Medicine ; R ; Science ; Q
    Subject code 616
    Language English
    Publishing date 2022-11-01T00:00:00Z
    Publisher Nature Portfolio
    Document type Article ; Online
    Database BASE - Bielefeld Academic Search Engine (life sciences selection)

    More links

    Kategorien

  10. Article ; Online: Optic Nerve Ultrasound Evaluation in Animals and Normal Subjects

    Livio Vitiello / Maddalena De Bernardo / Luigi Capasso / Palmiro Cornetta / Nicola Rosa

    Frontiers in Medicine, Vol

    2022  Volume 8

    Abstract: In recent years, ultrasonographic measurement of the optic nerve sheath diameter (ONSD) has been widely used to identify the presence of increased intracranial pressure (ICP). Intracranial hypertension is a life-threatening condition that can be caused ... ...

    Abstract In recent years, ultrasonographic measurement of the optic nerve sheath diameter (ONSD) has been widely used to identify the presence of increased intracranial pressure (ICP). Intracranial hypertension is a life-threatening condition that can be caused by various neurological and non-neurological disorders, and it is associated to poor clinical results. Ultrasonography could be used to qualitatively and efficiently detect ICP increases, but to reach this purpose, clear cut-off values are mandatory. The aim of this review is to provide a wide overview of the most important scientific publications on optic nerve ultrasound normal values assessment published in the last 30 years. A total of 42 articles selected from PubMed medical database was included in this review. Our analysis showed that ocular ultrasonography is considered to be a valuable diagnostic tool, especially when intracranial hypertension is suspected, but unfortunately this research provided conflicting results that could be due to the different ultrasound protocols. This is mainly caused by the use of B scan alone, which presents several limitations. The use of B-scan coupled with the standardized A-scan approach could give more accurate, and reliable ultrasound evaluation, assuring higher data objectivity.
    Keywords intracranial hypertension ; optic nerve ; optic nerve sheath diameter ; ONSD ; ultrasonography ; Medicine (General) ; R5-920
    Subject code 616
    Language English
    Publishing date 2022-01-01T00:00:00Z
    Publisher Frontiers Media S.A.
    Document type Article ; Online
    Database BASE - Bielefeld Academic Search Engine (life sciences selection)

    More links

    Kategorien

To top