  1. Article: Microfluidic devices for label-free and non-instrumented quantitation of unamplified nucleic acids by flow distance measurement

    Chatterjee, Debolina / Mansfield, Danielle S / Woolley, Adam T

    Analytical methods. 2014 Sept. 25, v. 6, no. 20

    2014  

    Abstract: Timely biomarker quantitation has potential to improve human health but current methods have disadvantages either in terms of cost and complexity for benchtop instruments, or reduced performance in quantitation and/or multiplexing for point-of-care ... ...

    Abstract Timely biomarker quantitation has potential to improve human health but current methods have disadvantages either in terms of cost and complexity for benchtop instruments, or reduced performance in quantitation and/or multiplexing for point-of-care systems. We previously developed microfluidic devices wherein visually observed flow distances correlated with a model analyte's concentration (Chatterjee et al., Anal. Chem., 2012, 84, 7057). Here, we significantly expand over this prior result to demonstrate the measurement of unamplified DNA analogues of microRNAs (miRNAs), biomarkers whose levels can be altered in disease states. We have developed a method for covalently attaching nucleic acid receptors on poly(dimethylsiloxane) microchannel surfaces by silane and cross-linker treatments. We found a flow distance dependence on target concentrations from 10 μg mL−1 to 10 pg mL−1 for DNA in both buffer and synthetic urine. Moreover, flow time in addition to flow distance is correlated with target concentration. We also observed longer flow distances for single-base mismatches compared to the target sequence at the same concentration, indicating that our approach can be used to detect point mutations. Finally, experiments with DNA analogues of miRNA biomarkers for kidney disease (mir-200c-3p) and prostate cancer (mir-107) in synthetic urine showed the ability to detect these analytes near clinically relevant levels. Our results demonstrate that these novel microfluidic assays offer a simple route to sensitive, amplification-free nucleic acid quantitation, with strong potential for point-of-care application.
    Keywords DNA ; analytical methods ; biomarkers ; chemical bonding ; chemical species ; human health ; kidney diseases ; microRNA ; models ; point mutation ; point-of-care systems ; prostatic neoplasms ; receptors ; silane ; urine
    Language English
    Dates of publication 2014-0925
    Size p. 8173-8179.
    Publishing place The Royal Society of Chemistry
    Document type Article
    ZDB-ID 2515210-5
    ISSN 1759-9679 ; 1759-9660
    ISSN (online) 1759-9679
    ISSN 1759-9660
    DOI 10.1039/c4ay01845a
    Database NAL-Catalogue (AGRICOLA)

    More links

    Kategorien

  2. Article: MICROFLUIDIC DEVICES FOR LABEL-FREE AND NON-INSTRUMENTED QUANTITATION OF UNAMPLIFIED NUCLEIC ACIDS BY FLOW DISTANCE MEASUREMENT.

    Chatterjee, Debolina / Mansfield, Danielle S / Woolley, Adam T

    Analytical methods : advancing methods and applications

    2014  Volume 6, Issue 20, Page(s) 8173–8179

    Abstract: Timely biomarker quantitation has potential to improve human health but current methods have disadvantages either in terms of cost and complexity for benchtop instruments, or reduced performance in quantitation and/or multiplexing for point-of-care ... ...

    Abstract Timely biomarker quantitation has potential to improve human health but current methods have disadvantages either in terms of cost and complexity for benchtop instruments, or reduced performance in quantitation and/or multiplexing for point-of-care systems. We previously developed microfluidic devices wherein visually observed flow distances correlated with a model analyte's concentration.
    Language English
    Publishing date 2014-12-11
    Publishing country England
    Document type Journal Article
    ZDB-ID 2515210-5
    ISSN 1759-9679 ; 1759-9660
    ISSN (online) 1759-9679
    ISSN 1759-9660
    DOI 10.1039/C4AY01845A
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  3. Article: “Flow Valve” Microfluidic Devices for Simple, Detectorless, and Label-Free Analyte Quantitation

    Chatterjee, Debolina / Anderson Neil G / Mansfield Danielle S / Subedi Sudeep / Woolley Adam T

    Analytical chemistry. 2012 Aug. 21, v. 84, no. 16

    2012  

    Abstract: Simplified analysis systems that offer the performance of benchtop instruments but the convenience of portability are highly desirable. We have developed novel, miniature devices that feature visual inspection readout of a target’s concentration from a ...

    Abstract Simplified analysis systems that offer the performance of benchtop instruments but the convenience of portability are highly desirable. We have developed novel, miniature devices that feature visual inspection readout of a target’s concentration from a ∼1 μL volume of solution introduced into a microfluidic channel. Microchannels are constructed within an elastomeric material, and channel surfaces are coated with receptors to the target. When a solution is flowed into the channel, the target cross-links multiple receptors on the surface, resulting in constriction of the first few millimeters of the channel and stopping of flow. Quantitation is performed by measuring the distance traveled by the target solution in the channel before flow stops. A key advantage of our approach is that quantitation is accomplished by simple visual inspection of the channel, without the need for complex detection instrumentation. We have tested these devices using the model system of biotin as a receptor and streptavidin as the target. We have also characterized three factors that influence flow distance: solution viscosity, device thickness, and channel height. We found that solution capillary flow distance scales with the negative logarithm of target concentration and have detected streptavidin concentrations as low as 1 ng/mL. Finally, we have identified and evaluated a plausible mechanism wherein time-dependent channel constriction in the first few millimeters leads to concentration-dependent flow distances. Their simplicity coupled with performance makes these “flow valve” systems especially attractive for a host of analysis applications.
    Keywords biotin ; crosslinking ; instrumentation ; receptors ; streptavidin ; systems analysis ; viscosity
    Language English
    Dates of publication 2012-0821
    Size p. 7057-7063.
    Publishing place American Chemical Society
    Document type Article
    ZDB-ID 1508-8
    ISSN 1520-6882 ; 0003-2700
    ISSN (online) 1520-6882
    ISSN 0003-2700
    DOI 10.1021%2Fac301278s
    Database NAL-Catalogue (AGRICOLA)

    More links

    Kategorien

  4. Article ; Online: "Flow valve" microfluidic devices for simple, detectorless, and label-free analyte quantitation.

    Chatterjee, Debolina / Mansfield, Danielle S / Anderson, Neil G / Subedi, Sudeep / Woolley, Adam T

    Analytical chemistry

    2012  Volume 84, Issue 16, Page(s) 7057–7063

    Abstract: Simplified analysis systems that offer the performance of benchtop instruments but the convenience of portability are highly desirable. We have developed novel, miniature devices that feature visual inspection readout of a target's concentration from a ~ ... ...

    Abstract Simplified analysis systems that offer the performance of benchtop instruments but the convenience of portability are highly desirable. We have developed novel, miniature devices that feature visual inspection readout of a target's concentration from a ~1 μL volume of solution introduced into a microfluidic channel. Microchannels are constructed within an elastomeric material, and channel surfaces are coated with receptors to the target. When a solution is flowed into the channel, the target cross-links multiple receptors on the surface, resulting in constriction of the first few millimeters of the channel and stopping of flow. Quantitation is performed by measuring the distance traveled by the target solution in the channel before flow stops. A key advantage of our approach is that quantitation is accomplished by simple visual inspection of the channel, without the need for complex detection instrumentation. We have tested these devices using the model system of biotin as a receptor and streptavidin as the target. We have also characterized three factors that influence flow distance: solution viscosity, device thickness, and channel height. We found that solution capillary flow distance scales with the negative logarithm of target concentration and have detected streptavidin concentrations as low as 1 ng/mL. Finally, we have identified and evaluated a plausible mechanism wherein time-dependent channel constriction in the first few millimeters leads to concentration-dependent flow distances. Their simplicity coupled with performance makes these "flow valve" systems especially attractive for a host of analysis applications.
    MeSH term(s) Animals ; Biotin/metabolism ; Chemistry Techniques, Analytical/instrumentation ; Equipment Design ; Microfluidic Analytical Techniques/instrumentation ; Streptavidin/metabolism
    Chemical Substances Biotin (6SO6U10H04) ; Streptavidin (9013-20-1)
    Language English
    Publishing date 2012-08-10
    Publishing country United States
    Document type Journal Article ; Research Support, N.I.H., Extramural
    ZDB-ID 1508-8
    ISSN 1520-6882 ; 0003-2700
    ISSN (online) 1520-6882
    ISSN 0003-2700
    DOI 10.1021/ac301278s
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien