LIVIVO - The Search Portal for Life Sciences

zur deutschen Oberfläche wechseln
Advanced search

Search results

Result 1 - 1 of total 1

Search options

Article ; Online: AR2, a novel automatic muscle artifact reduction software method for ictal EEG interpretation

Shennan Aibel Weiss / Ali A Asadi-Pooya / Sitaram Vangala / Stephanie Moy / Dale H Wyeth / Iren Orosz / Michael Gibbs / Lara Schrader / Jason Lerner / Christopher K Cheng / Edward Chang / Rajsekar Rajaraman / Inna Keselman / Perdro Churchman / Christine Bower-Baca / Adam L Numis / Michael G Ho / Lekha Rao / Annapoorna Bhat /
Joanna Suski / Marjan Asadollahi / Timothy Ambrose / Andres Fernandez / Maromi Nei / Christopher Skidmore / Scott Mintzer / Dawn S Eliashiv / Gary W Mathern / Marc R Nuwer / Michael Sperling / Jerome Engel Jr / John M Stern

F1000Research, Vol

Validation and comparison of performance with commercially available software [version 2; referees: 2 approved]

2017  Volume 6

Abstract: Objective: To develop a novel software method (AR2) for reducing muscle contamination of ictal scalp electroencephalogram (EEG), and validate this method on the basis of its performance in comparison to a commercially available software method (AR1) to ... ...

Abstract Objective: To develop a novel software method (AR2) for reducing muscle contamination of ictal scalp electroencephalogram (EEG), and validate this method on the basis of its performance in comparison to a commercially available software method (AR1) to accurately depict seizure-onset location. Methods: A blinded investigation used 23 EEG recordings of seizures from 8 patients. Each recording was uninterpretable with digital filtering because of muscle artifact and processed using AR1 and AR2 and reviewed by 26 EEG specialists. EEG readers assessed seizure-onset time, lateralization, and region, and specified confidence for each determination. The two methods were validated on the basis of the number of readers able to render assignments, confidence, the intra-class correlation (ICC), and agreement with other clinical findings. Results: Among the 23 seizures, two-thirds of the readers were able to delineate seizure-onset time in 10 of 23 using AR1, and 15 of 23 using AR2 (p<0.01). Fewer readers could lateralize seizure-onset (p<0.05). The confidence measures of the assignments were low (probable-unlikely), but increased using AR2 (p<0.05). The ICC for identifying the time of seizure-onset was 0.15 (95% confidence interval (CI), 0.11-0.18) using AR1 and 0.26 (95% CI 0.21-0.30) using AR2. The EEG interpretations were often consistent with behavioral, neurophysiological, and neuro-radiological findings, with left sided assignments correct in 95.9% (CI 85.7-98.9%, n=4) of cases using AR2, and 91.9% (77.0-97.5%) (n=4) of cases using AR1. Conclusions: EEG artifact reduction methods for localizing seizure-onset does not result in high rates of interpretability, reader confidence, and inter-reader agreement. However, the assignments by groups of readers are often congruent with other clinical data. Utilization of the AR2 software method may improve the validity of ictal EEG artifact reduction.
Keywords Neuroimaging ; Medicine ; R ; Science ; Q
Subject code 616
Language English
Publishing date 2017-04-01T00:00:00Z
Publisher F1000 Research Ltd
Document type Article ; Online
Database BASE - Bielefeld Academic Search Engine (life sciences selection)

More links

Kategorien

To top