Article ; Online: Automated False Alarm Reduction in a Real-Life Intensive Care Setting Using Motion Detection.
2019 Volume 32, Issue 2, Page(s) 419–426
Abstract: Background: Contemporary monitoring systems are sensitive to motion artifacts and cause an excess of false alarms. This results in alarm fatigue and hazardous alarm desensitization. To reduce the number of false alarms, we developed and validated a ... ...
Abstract | Background: Contemporary monitoring systems are sensitive to motion artifacts and cause an excess of false alarms. This results in alarm fatigue and hazardous alarm desensitization. To reduce the number of false alarms, we developed and validated a novel algorithm to classify alarms, based on automatic motion detection in videos. Methods: We considered alarms generated by the following continuously measured parameters: arterial oxygen saturation, systolic blood pressure, mean blood pressure, heart rate, and mean intracranial pressure. The movements of the patient and in his/her surroundings were monitored by a camera situated at the ceiling. Using the algorithm, alarms were classified into RED (true), ORANGE (possibly false), and GREEN alarms (false, i.e., artifact). Alarms were reclassified by blinded clinicians. The performance was evaluated using confusion matrices. Results: A total of 2349 alarms from 45 patients were reclassified. For RED alarms, sensitivity was high (87.0%) and specificity was low (29.6%) for all parameters. As the sensitivities and specificities for RED and GREEN alarms are interrelated, the opposite was observed for GREEN alarms, i.e., low sensitivity (30.2%) and high specificity (87.2%). As RED alarms should not be missed, even at the expense of false positives, the performance was acceptable. The low sensitivity for GREEN alarms is acceptable, as it is not harmful to tag a GREEN alarm as RED/ORANGE. It still contributes to alarm reduction. However, a 12.8% false-positive rate for GREEN alarms is critical. Conclusions: The proposed system is a step forward toward alarm reduction; however, implementation of additional layers, such as signal curve analysis, multiple parameter correlation analysis and/or more sophisticated video-based analytics are needed for improvement. |
|||||
---|---|---|---|---|---|---|
MeSH term(s) | Alert Fatigue, Health Personnel/prevention & control ; Automation ; Blood Pressure ; Clinical Alarms/classification ; Heart Rate ; Humans ; Intensive Care Units ; Intracranial Pressure ; Monitoring, Physiologic/methods ; Motion | |||||
Language | English | |||||
Publishing date | 2019-07-09 | |||||
Publishing country | United States | |||||
Document type | Journal Article ; Observational Study ; Research Support, Non-U.S. Gov't | |||||
ZDB-ID | 2381896-7 | |||||
ISSN | 1556-0961 ; 1541-6933 | |||||
ISSN (online) | 1556-0961 | |||||
ISSN | 1541-6933 | |||||
DOI | 10.1007/s12028-019-00711-w | |||||
Shelf mark |
|
|||||
Database | MEDical Literature Analysis and Retrieval System OnLINE |
Full text online
More links
Kategorien
In stock of ZB MED Cologne/Königswinter
Zs.A 6538: Show issues | Location: Je nach Verfügbarkeit (siehe Angabe bei Bestand) bis Jg. 2021: Bestellungen von Artikeln über das Online-Bestellformular ab Jg. 2022: Lesesaal (EG) |
Order via subito
This service is chargeable due to the Delivery terms set by subito. Orders including an article and supplementary material will be classified as separate orders. In these cases, fees will be demanded for each order.