Article ; Online: Evaluation status of current and emerging minimally invasive robotic surgical platforms.

Boal, M / Di Girasole, C Giovene / Tesfai, F / Morrison, T E M / Higgs, S / Ahmad, J / Arezzo, A / Francis, N

Surgical endoscopy

2023  Volume 38, Issue 2, Page(s) 554–585

Abstract: Background: The rapid adoption of robotics within minimally invasive surgical specialties has also seen an explosion of new technology including multi- and single port, natural orifice transluminal endoscopic surgery (NOTES), endoluminal and "on-demand" ...

Abstract Background: The rapid adoption of robotics within minimally invasive surgical specialties has also seen an explosion of new technology including multi- and single port, natural orifice transluminal endoscopic surgery (NOTES), endoluminal and "on-demand" platforms. This review aims to evaluate the validation status of current and emerging MIS robotic platforms, using the IDEAL Framework.
Methods: A scoping review exploring robotic minimally invasive surgical devices, technology and systems in use or being developed was performed, including general surgery, gynaecology, urology and cardiothoracics. Systems operating purely outside the abdomen or thorax and endoluminal or natural orifice platforms were excluded. PubMed, Google Scholar, journal reports and information from the public domain were collected. Each company was approached via email for a virtual interview to discover more about the systems and to quality check data. The IDEAL Framework is an internationally accepted tool to evaluate novel surgical technology, consisting of four stages: idea, development/exploration, assessment, and surveillance. An IDEAL stage, synonymous with validation status in this review, was assigned by reviewing the published literature.
Results: 21 companies with 23 different robotic platforms were identified for data collection, 13 with national and/or international regulatory approval. Of the 17 multiport systems, 1 is fully evaluated at stage 4, 2 are stage 3, 6 stage 2b, 2 at stage 2a, 2 stage 1, and 4 at the pre-IDEAL stage 0. Of the 6 single-port systems none have been fully evaluated with 1 at stage 3, 3 at stage 1 and 2 at stage 0.
Conclusions: The majority of existing robotic platforms are currently at the preclinical to developmental and exploratory stage of evaluation. Using the IDEAL framework will ensure that emerging robotic platforms are fully evaluated with long-term data, to inform the surgical workforce and ensure patient safety.
MeSH term(s) Humans ; Robotics ; Minimally Invasive Surgical Procedures ; Natural Orifice Endoscopic Surgery ; Gynecology ; Robotic Surgical Procedures ; Laparoscopy
Language English
Publishing date 2023-12-20
Publishing country Germany
Document type Journal Article ; Review
ZDB-ID 639039-0
ISSN 1432-2218 ; 0930-2794
ISSN (online) 1432-2218
ISSN 0930-2794
DOI 10.1007/s00464-023-10554-4
Shelf mark
Zs.A 2214: Show issues Location:
Je nach Verfügbarkeit (siehe Angabe bei Bestand)
bis Jg. 1994: Bestellungen von Artikeln über das Online-Bestellformular
Jg. 1995 - 2021: Lesesall (1.OG)
ab Jg. 2022: Lesesaal (EG)
Database MEDical Literature Analysis and Retrieval System OnLINE

More links

Kategorien

To top