LIVIVO - The Search Portal for Life Sciences

zur deutschen Oberfläche wechseln
Advanced search

Search results

Result 1 - 4 of total 4

Search options

  1. Article ; Online: Influence of Implant Macro-Design, -Length, and -Diameter on Primary Implant Stability Depending on Different Bone Qualities Using Standard Drilling Protocols—An In Vitro Analysis

    Milan Stoilov / Ramin Shafaghi / Helmut Stark / Michael Marder / Dominik Kraus / Norbert Enkling

    Journal of Functional Biomaterials, Vol 14, Iss 469, p

    2023  Volume 469

    Abstract: 1) Background: Primary implant stability is vital for successful implant therapy. This study explores the influence of implant shape, length, and diameter on primary stability in different bone qualities. (2) Methods: Three implant systems (two parallel- ...

    Abstract (1) Background: Primary implant stability is vital for successful implant therapy. This study explores the influence of implant shape, length, and diameter on primary stability in different bone qualities. (2) Methods: Three implant systems (two parallel-walled and one tapered) with various lengths and diameters were inserted into polyurethane foam blocks of different densities (35, 25, 15, and 10 PCF) using standard drilling protocols. Primary stability was assessed through insertion torque (IT) and resonance frequency analysis (RFA). Optimal ranges were defined for IT (25 to 50 Ncm) and RFA (ISQ 60 to 80). A comparison of implant groups was conducted to determine adherence to the optimal ranges. (3) Results: Implant macro-design, -length, and -diameter and bone block density significantly influenced IT and RFA. Optimal IT was observed in 8/40 and 9/40 groups for the parallel-walled implants, while the tapered implant achieved optimal IT in 13/40 groups (within a 25–50 Ncm range). Implant diameter strongly impacted primary stability, with sufficient stability achieved in only one-third of cases despite the tapered implant’s superiority. (4) Conclusions: The findings highlight the need to adapt the drilling protocol based on diverse bone qualities in clinical practice. Further investigations should explore the impact of these adapted protocols on implant outcomes.
    Keywords immediate loading ; primary stability ; insertion torque ; ISQ ; RFA ; bone quality ; Biotechnology ; TP248.13-248.65 ; Medicine (General) ; R5-920
    Subject code 600
    Language English
    Publishing date 2023-09-01T00:00:00Z
    Publisher MDPI AG
    Document type Article ; Online
    Database BASE - Bielefeld Academic Search Engine (life sciences selection)

    More links

    Kategorien

  2. Article ; Online: Converting Bilateral Free-End Removable Partial Dentures to Implant-Assisted Removable Partial Dentures Using 6 mm Short Implants

    Samir Abou-Ayash / Anne-Carole Rudaz / Simone Janner / Dominik Kraus / Martin Schimmel / Norbert Enkling

    International Journal of Environmental Research and Public Health, Vol 19, Iss 8998, p

    Patient-Reported Outcomes of a Prospective Clinical Study

    2022  Volume 8998

    Abstract: The study assessed oral health-related quality of life (OHRQoL) of patients who received two 6 mm short implants in mandibular molar sites, converting existing bilateral free-end removable partial dentures (RPDs) to implant-assisted RPDs (IARPDs). After ... ...

    Abstract The study assessed oral health-related quality of life (OHRQoL) of patients who received two 6 mm short implants in mandibular molar sites, converting existing bilateral free-end removable partial dentures (RPDs) to implant-assisted RPDs (IARPDs). After a postsurgical healing period of 4 months, the participants received a non-retentive dome abutment for 8 weeks, and then a retentive ball abutment for another 8 weeks. Afterwards, the participants made their final choice on which abutment to keep. The final follow-up was 1 year after implant placement. OHRQoL was evaluated with the 49-items version of the Oral Health Impact Profile (OHIP-49) at the abutment exchanges and the final follow-up. Furthermore, numerical rating scales were used to analyze patient satisfaction after 1 year. Questionnaire data of 13 participants were evaluated. Overall, OHRQoL increased with both the dome ( p = 0.02) and the ball abutments ( p < 0.001), without a significant difference between the abutments ( p = 0.953). The questionnaires revealed an improvement in terms of oral situation, quality of life, and masticatory capacity (all p < 0.01). Patients showed a significant preference for the ball abutments ( p < 0.001). Converting RPDs to IARPDs resulted in significant improvement of OHRQoL. Patients seem to prefer retentive over non-retentive abutments, although no differences in terms of OHRQoL were observed.
    Keywords OHIP ; oral health-related quality of life ; short implants ; patient-reported outcomes ; patient satisfaction ; abutment type ; Medicine ; R
    Language English
    Publishing date 2022-07-01T00:00:00Z
    Publisher MDPI AG
    Document type Article ; Online
    Database BASE - Bielefeld Academic Search Engine (life sciences selection)

    More links

    Kategorien

  3. Article ; Online: Comparison of Digital Self-Assessment Systems and Faculty Feedback for Tooth Preparation in a Preclinical Simulation

    Milan Stoilov / Lea Trebess / Markus Klemmer / Helmut Stark / Norbert Enkling / Dominik Kraus

    International Journal of Environmental Research and Public Health, Vol 18, Iss 13218, p

    2021  Volume 13218

    Abstract: Background: Regarding the new dental licensing regulations in Germany (AOZ), this study evaluated the effectiveness of two different digital tooth preparation validation systems in comparison to traditional faculty feedback. Methods: Participants were ... ...

    Abstract Background: Regarding the new dental licensing regulations in Germany (AOZ), this study evaluated the effectiveness of two different digital tooth preparation validation systems in comparison to traditional faculty feedback. Methods: Participants were randomly divided into groups: Faculty Feedback (FF: n = 33), PrepCheck ® (PC: n = 32) and Dental Teacher™ (n = 32). Students had the task to prepare tooth 16 for a retentive full-cast crown. Preparations could be repeated as often as desired. Feedback was provided either by faculty staff or by digital validation systems only. Exams were conducted and graded by two independent and experienced examiners. A survey was performed to evaluate the assessment concepts. Results: No statistical difference in examination performance between groups could be observed. Nevertheless, the survey showed participants preferred consulting the faculty staff rather than the digital validation systems. Students preferred practising with DT rather than with PC. Conclusions: Although both classical and digital methods showed comparable results regarding the preparation examination performance, direct feedback by the faculty staff is still appreciated by the students. A combination of both methods is mandatory since demonstration and advice by the teacher is needed. However, digital tooth preparation validation systems are predestined for free practice sessions, providing self-assessment.
    Keywords digital assessment ; self-assessment ; compare software ; dental education ; digital dentistry ; Medicine ; R
    Subject code 370
    Language English
    Publishing date 2021-12-01T00:00:00Z
    Publisher MDPI AG
    Document type Article ; Online
    Database BASE - Bielefeld Academic Search Engine (life sciences selection)

    More links

    Kategorien

  4. Article ; Online: Wear of double crown systems

    Stefan Bayer / Dominik Kraus / Ludger Keilig / Lina Gölz / Helmut Stark / Norbert Enkling

    Journal of Applied Oral Science, Vol 20, Iss 3, Pp 384-

    electroplated vs. casted female part

    2012  Volume 391

    Abstract: OBJECTIVES: The wear of telescopic crowns is a common problem often reducing the patient's satisfaction with the denture and resulting in a renewal of the denture. The study aims to compare the wear behavior of conical crowns using electroplated copings ( ...

    Abstract OBJECTIVES: The wear of telescopic crowns is a common problem often reducing the patient's satisfaction with the denture and resulting in a renewal of the denture. The study aims to compare the wear behavior of conical crowns using electroplated copings (group E ) with standard telescopic crowns with cast female parts (group C). MATERIAL AND METHODS: 10 conical crowns were milled for each group of a cast gold alloy. The specimen of group E had a conicity of 2º. The cast secondary crowns of group C had a 0º design. The electroplated coping was established by direct electroforming. An apparatus accomplishing 10,000 wear cycles performed the wear test. The retentive forces and the correlating distance during insertion and separation were measured. The wear test was separated in a start phase, an initial wear phase and the long term wear period. The retention force value and the force-distance integral of the first 0.33 mm of each cycle were calculated. RESULTS: The retentive forces were significantly higher for group E and the integrals were significantly lower for this group except the integral at cycle 10,000. The changes of retention force and integral did not differ significantly between both groups in all phases. The change of the integrals as well as the integral at the particular cycles showed higher interquartile distances for group C. CONCLUSIONS: Within the limitations of this study the tested conical crowns showed clinically acceptable retentive properties. The values reached a range comparable to retentive elements tested in recent literature. The values of group C showed higher ranges. The force measured for group E was significantly higher than for group C but the integrals showed an opposite tendency. The results indicate that an exclusive analysis of the force is not sufficient as the integral is not equivalent to the force although it describes the retentive property of the system in a better way than the force over a distance is described. Both systems seem to be suitable for clinical practice.
    Keywords Dental restoration wear ; Denture retention ; Dental prosthesis ; Implantsupported denture ; Overlay denture ; Denture precision attachment ; Dentistry ; RK1-715 ; Medicine ; R ; DOAJ:Dentistry ; DOAJ:Health Sciences
    Subject code 796
    Language English
    Publishing date 2012-06-01T00:00:00Z
    Publisher University of São Paulo
    Document type Article ; Online
    Database BASE - Bielefeld Academic Search Engine (life sciences selection)

    More links

    Kategorien

To top