LIVIVO - The Search Portal for Life Sciences

zur deutschen Oberfläche wechseln
Advanced search

Search results

Result 1 - 1 of total 1

Search options

Article: Nerve Regeneration and Gait Function Recovery with Implantation of Glucose/Mannose Conduits Using a Rat Model: Efficacy of Glucose/Mannose as a New Neurological Guidance Material.

Yamamoto, Osamu / Saito, Risa / Ohseki, Yuta / Hoshino, Asami

Bioengineering (Basel, Switzerland)

2024  Volume 11, Issue 2

Abstract: Therapy with clinical nerve guidance conduits often causes functional incompleteness in patients. With the aim of better therapeutic efficacy, nerve regeneration and gait function were investigated in this study using a novel nerve guidance conduit ... ...

Abstract Therapy with clinical nerve guidance conduits often causes functional incompleteness in patients. With the aim of better therapeutic efficacy, nerve regeneration and gait function were investigated in this study using a novel nerve guidance conduit consisting of glucose/mannose. The glucose/mannose nerve guidance conduits were prepared by filling the conduits with the glucose/mannose aqueous solutions for different kinematic viscosity, which were applied to sciatic nerve defects (6 mm gap) in a rat model. The nerve regeneration effect and the gait function recovery with the fabricated nerve guidance conduits were examined. From the results of the XRD measurement, the glucose/mannose conduits were identified as crystal structures of cellulose type II. Young's modulus and the maximum tensile strength of the crystalline glucose/mannose conduits demonstrated good strength and softness for the human nerve. Above 4 weeks postoperative, macroscopic observation revealed that the nerve was regenerated in the defective area. In various staining results of the nerve tissue removed at 4 weeks postoperative, myelinated nerves contributing to gait function could not be observed in the proximal and distal sites to the central nerve. At 8-12 weeks postoperative, myelinated nerves were found at the proximal and distal sites in hematoxylin/eosin staining. Glia cells were confirmed by phosphotungstic acid-hematoxylin staining. Continuous nerve fibers were observed clearly in the sections of the regenerated nerves towards the longitudinal direction at 12 weeks postoperative. The angle between the metatarsophalangeal joint and the ground plane was approximately 93° in intact rats. At 4 weeks postoperative, walking was not possible, but at 8 weeks postoperative, the rats were able to walk, with an angle of 53°. At 12 weeks postoperative, the angle increased further, reaching 65°, confirming that the rats were able to walk more quickly than at 8 weeks postoperative. These results demonstrated that gait function in rats treated with glucose/mannose nerve guidance conduits was rapidly recovered after 8 weeks postoperative. The glucose/mannose nerve guidance conduit could be applied as a new promising candidate material for peripheral nerve regeneration.
Language English
Publishing date 2024-02-04
Publishing country Switzerland
Document type Journal Article
ZDB-ID 2746191-9
ISSN 2306-5354
ISSN 2306-5354
DOI 10.3390/bioengineering11020157
Database MEDical Literature Analysis and Retrieval System OnLINE

More links

Kategorien

To top