LIVIVO - The Search Portal for Life Sciences

zur deutschen Oberfläche wechseln
Advanced search

Search results

Result 1 - 2 of total 2

Search options

  1. Article: A Comparative Study to Check the Accuracy of Tooth Shade Selection With Standardized Digital Photographs and a Spectrophotometer.

    Hina, Malik / Ali, Md Sadique / Pande, Deepmala / Pandey, Kaushik Kumar / Kandwal, Nikhil / Tasar, Doyir / Jadhav, Monika S / Xavier, Sruthy / S, Gokulkrishna

    Cureus

    2024  Volume 16, Issue 3, Page(s) e56073

    Abstract: Background: The success of any dental prosthesis depends on aesthetics and function. A proper shade selection is a prime requisite for providing aesthetics to dental patients.: Purpose: This study aims to compare the photographic method of shade ... ...

    Abstract Background: The success of any dental prosthesis depends on aesthetics and function. A proper shade selection is a prime requisite for providing aesthetics to dental patients.
    Purpose: This study aims to compare the photographic method of shade selection with that of a digital spectrophotometer.
    Materials and methods: The study included 50 participants. The primary inclusion criterion was the presence of the maxillary left central incisor without a history of restorative or endodontic procedures. The shade of the left maxillary central incisor was determined using the VITA Easyshade V spectrophotometer (VITA Zahnfabrik, BadSäckingen, Germany) and the digital photography method for all the selected participants. The CIELAB colour space utilizes three values (L*, a*, and b*) to objectively measure colour. While the digital photography approach used Adobe Photoshop software (Adobe Systems Incorporated, San Jose, CA) to report solely the L*, a*, and b* values, the spectrophotometer reported the L*, a*, and b* values along with the actual shade. After obtaining the values of L*, a*, and b*, ΔE, which is their difference, was calculated using a standard formula. Statistical analysis was carried out by using Student's t-test and proportion z-test.
    Results: When the comparison of the L*a*b* values was done, Student's t-test showed similar (P>0.05) L(t=0.16, P=0.872), a (t=0.52, P=0.607), and b (t=0.23, P=0.820) values between the two groups; that is, they did not differ significantly or showed perfect matching. There was agreement (ΔE≤2) in 42 (84.0%) cases and disagreement (ΔE>2) in eight (16.0%) cases. The proportion z-test showed an agreement of 84.0%, which was statistically highly significant (z=20.44, P<0.001).
    Conclusion: The true shade of the teeth can be depicted using standardized digital images.
    Language English
    Publishing date 2024-03-13
    Publishing country United States
    Document type Journal Article
    ZDB-ID 2747273-5
    ISSN 2168-8184
    ISSN 2168-8184
    DOI 10.7759/cureus.56073
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  2. Article: Minimally invasive techniques for sinus floor elevation using dental implants among Indians.

    Laskar, Shyamalendu / Pande, Deepmala / Anwar, Md Shadab / Langaliya, Akshayraj / Shukla, Ruchira / Shrivastava, Harshit / Mehta, Dhaval Niranjan / Acharya, Sheetal

    Bioinformation

    2023  Volume 19, Issue 13, Page(s) 1336–1341

    Abstract: It is of interest to compare conventional lateral window technique, trans-alveolar technique with minimally invasive technique like modified trephine technique and antral membrane balloon elevation technique for sinus floor elevation in placement of ... ...

    Abstract It is of interest to compare conventional lateral window technique, trans-alveolar technique with minimally invasive technique like modified trephine technique and antral membrane balloon elevation technique for sinus floor elevation in placement of dental implants. The current study included 140 participants (191 dental implants) who had maxillary posterior edentulous regions and had low sinuses and insufficient alveolar ridges but had chosen an implant-retained prosthesis. The minimally invasive techniques of sinus augmentation can be suitable alternative to conventional traumatic techniques due to low incidence of pain, gingival swelling. Moreover, the success rate of implants and increase in total bone height was almost same in minimally invasive techniques of sinus augmentation as compared to conventional traumatic techniques.
    Language English
    Publishing date 2023-12-31
    Publishing country Singapore
    Document type Journal Article
    ZDB-ID 2203786-X
    ISSN 0973-2063
    ISSN 0973-2063
    DOI 10.6026/973206300191336
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

To top