LIVIVO - The Search Portal for Life Sciences

zur deutschen Oberfläche wechseln
Advanced search

Search results

Result 1 - 4 of total 4

Search options

  1. Article ; Online: Validation of non-empirical fat-free mass estimation model for a wrist-worn device

    Polokhin Aleksandr / Pronina Anna / Boev Andrey / Gorbunov Stas

    Journal of Electrical Bioimpedance, Vol 13, Iss 1, Pp 31-

    2022  Volume 38

    Abstract: Fat-free mass (FFM) estimation has dramatic importance for body composition evaluation, often providing a basis for treatment of obesity and muscular dystrophy. However, current methods of FFM estimation have several drawbacks, usually related to either ... ...

    Abstract Fat-free mass (FFM) estimation has dramatic importance for body composition evaluation, often providing a basis for treatment of obesity and muscular dystrophy. However, current methods of FFM estimation have several drawbacks, usually related to either cost-effectiveness and equipment size (dual-energy X-ray absorptiometry (DEXA) scan) or model limitations. In this study, we present and validate a new FFM estimation model based on hand-to-hand bioimpedance analysis (BIA) and arm volume. Forty-two participants underwent a full-body DEXA scan, a series of anthropometric measurements, and upper-body BIA measurements with the custom-designed wearable wrist-worn impedance meter. A new two truncated cones (TTC) model was trained on DEXA data and achieved the best performance metrics of 0.886 ± 0.051 r2, 0.052 ± 0.009 % mean average error, and 6.884 ± 1.283 kg maximal residual error in FFM estimation. The model further demonstrated its effectiveness in Bland-Altman comparisons with the skinfold thickness-based FFM estimation method, achieving the least mean bias (0.007 kg). The novel TTC model can provide an alternative to full-body BIA measurements, demonstrating an accurate FFM estimation independently of population variables.
    Keywords bioelectrical impedance analysis ; fat free mass ; upper-body measurement ; multiple linear regression ; predictive modeling ; Medicine (General) ; R5-920
    Subject code 310
    Language English
    Publishing date 2022-06-01T00:00:00Z
    Publisher Sciendo
    Document type Article ; Online
    Database BASE - Bielefeld Academic Search Engine (life sciences selection)

    More links

    Kategorien

  2. Article ; Online: Validation of Non-empirical Fat-free Mass Estimation Model for a Wrist-worn Device.

    Polokhin, Aleksandr / Pronina, Anna / Boev, Andrey / Gorbunov, Stas

    Journal of electrical bioimpedance

    2022  Volume 13, Issue 1, Page(s) 31–38

    Abstract: Fat-free mass (FFM) estimation has dramatic importance for body composition evaluation, often providing a basis for treatment of obesity and muscular dystrophy. However, current methods of FFM estimation have several drawbacks, usually related to either ... ...

    Abstract Fat-free mass (FFM) estimation has dramatic importance for body composition evaluation, often providing a basis for treatment of obesity and muscular dystrophy. However, current methods of FFM estimation have several drawbacks, usually related to either cost-effectiveness and equipment size (dual-energy X-ray absorptiometry (DEXA) scan) or model limitations. In this study, we present and validate a new FFM estimation model based on hand-to-hand bioimpedance analysis (BIA) and arm volume. Forty-two participants underwent a full-body DEXA scan, a series of anthropometric measurements, and upper-body BIA measurements with the custom-designed wearable wrist-worn impedance meter. A new two truncated cones (TTC) model was trained on DEXA data and achieved the best performance metrics of 0.886 ± 0.051 r
    Language English
    Publishing date 2022-06-25
    Publishing country Poland
    Document type Journal Article
    ZDB-ID 2580506-X
    ISSN 1891-5469 ; 1891-5469
    ISSN (online) 1891-5469
    ISSN 1891-5469
    DOI 10.2478/joeb-2022-0006
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  3. Article: Tapered Optical Fiber Sensor Coated with Single-Walled Carbon Nanotubes for Dye Sensing Application.

    Polokhin, Aleksandr A / Shaman, Yuri P / Itrin, Pavel A / Panyaev, Ivan S / Sysa, Artem A / Selishchev, Sergey V / Kitsyuk, Evgeny P / Pavlov, Alexander A / Gerasimenko, Alexander Yu

    Micromachines

    2023  Volume 14, Issue 3

    Abstract: The present study aimed to improve the optical sensing performance of tapered optical fiber sensors toward aqueous Rhodamine B solution of different concentrations by applying single-walled carbon nanotubes (SWCNTs). The functional coating was formed on ... ...

    Abstract The present study aimed to improve the optical sensing performance of tapered optical fiber sensors toward aqueous Rhodamine B solution of different concentrations by applying single-walled carbon nanotubes (SWCNTs). The functional coating was formed on the surface of the tapered optical fiber sensor using an aerosol layer-by-layer deposition method. Before deposition, the SWCNTs were processed with multistage liquid-phase treatment in order to form a stable dispersion. The effect of SWCNT treatment was investigated through Raman spectroscopy. The deposition of 220 layers caused a reduction of up to 60% of the initial optical power of radiation propagating through the optical fiber core. The optical fiber sensor coated with SWCNTs demonstrated significantly higher sensitivity compared to a non-coated sensor in the range of 2-32 mg/L of Rhodamine B concentration in an aqueous solution. The experimental results demonstrated that the sensitivity was increased 10 times from 32 (mg/L)
    Language English
    Publishing date 2023-02-28
    Publishing country Switzerland
    Document type Journal Article
    ZDB-ID 2620864-7
    ISSN 2072-666X
    ISSN 2072-666X
    DOI 10.3390/mi14030579
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  4. Article ; Online: Tapered Optical Fiber Detector for a Red Dye Concentration Measurement.

    Polokhin, Aleksandr A / Kharissova, Oxana V / Torres-Martínez, Leticia M / Gerasimenko, Alexander Y / Selvas, Romeo / Jiang, Jiechao / Kharisov, Boris I

    Recent patents on nanotechnology

    2020  Volume 15, Issue 1, Page(s) 47–54

    Abstract: Background: In this work, a detector based on optical fiber covered with Multi-Wall Carbon Nanotubes (MWCNTs) was used for sensing and removal of Alizarin from wastewaters. Alizarin is a strong anionic red dye that is part of the anthraquinone dye group. ...

    Abstract Background: In this work, a detector based on optical fiber covered with Multi-Wall Carbon Nanotubes (MWCNTs) was used for sensing and removal of Alizarin from wastewaters. Alizarin is a strong anionic red dye that is part of the anthraquinone dye group. As a rule, this dye is used in the textile industry as a coloring agent. Experiments showed a good efficiency of wastewater treatment. This development could resolve the problem of water contamination with Alizarin red dye.
    Methods: We used a single-mode fiber SMF-28e with a core diameter of 8.2 μm and a cladding diameter of 125 μm as a base for the tapered optical fiber detector. An MWCNTs array was synthesized on the tapered optical fiber detector surface by spray pyrolysis Chemical Vapor Deposition (CVD) method at 800oC for 20 min inside a tubular furnace, using ferrocene solution in toluene as a catalyst precursor. The formed structure was applied for Alizarin detection in water.
    Results: According to the patent studies, the nanotubes completely covered the optical fiber surface and the array had a high density with minimal distance between nearby nanotubes. Carbon nanotubes were oriented along the radius of the optical fiber. The average diameter of carbon nanotubes was 24 nm. The optical absorbance levels increased as the Alizarin concentration increased from 50 mg/L to 1000 mg/L. MWCNTs on the optical fiber tapered section adsorbed the dye molecules from aqueous solution. Three intensive absorption bands with the wavelength of the 700, 714 and 730 nm appeared and their intensity increased as the Alizarin concentration increased. The accumulated Alizarin can be recovered by multiple immersing clean water. This property may make tapered optical fiber detector reusable and increase the economic expediency of the sensor application.
    Conclusion: The study showed higher Alizarin adsorption efficiency of the tapered optical fiber detector compared with relative detectors. This structure can be reusable for dye detection. Removal efficiency for Alizarin reached 98.6%, which makes the tapered optical fiber detector promising for wastewater treatment and dye elimination.
    Language English
    Publishing date 2020-06-26
    Publishing country United Arab Emirates
    Document type Journal Article
    ISSN 2212-4020
    ISSN (online) 2212-4020
    DOI 10.2174/1872210514666200626165916
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

To top