LIVIVO - The Search Portal for Life Sciences

zur deutschen Oberfläche wechseln
Advanced search

Search results

Result 1 - 1 of total 1

Search options

Article ; Online: Computed tomography pulmonary angiography in acute pulmonary embolism: the effect of a computer-assisted detection prototype used as a concurrent reader.

Wittenberg, Rianne / Peters, Joost F / van den Berk, Inge A H / Freling, Nicole J M / Lely, Rutger / de Hoop, Bartjan / Horsthuis, Karin / Ravesloot, Cécile J / Weber, Michael / Prokop, W Mathias / Schaefer-Prokop, Cornelia M

Journal of thoracic imaging

2013  Volume 28, Issue 5, Page(s) 315–321

Abstract: Purpose: To assess the effect of computer-assisted detection (CAD) on diagnostic accuracy, reader confidence, and reading time when used as a concurrent reader for the detection of acute pulmonary embolism in computed tomography pulmonary angiography.!## ...

Abstract Purpose: To assess the effect of computer-assisted detection (CAD) on diagnostic accuracy, reader confidence, and reading time when used as a concurrent reader for the detection of acute pulmonary embolism in computed tomography pulmonary angiography.
Materials and methods: In this institutional review board-approved retrospective study, 6 observers with varying experience evaluated 158 negative and 38 positive consecutive computed tomography pulmonary angiographies (mean patient age 60 y; 115 women) without and with CAD as a concurrent reader. Readers were asked to determine the presence of pulmonary embolism, assess their diagnostic confidence using a 5-point scale, and document their reading time. Results were compared with an independent standard established by 2 readers, and a third chest radiologist was consulted in case of discordant findings.
Results: Using logistic regression for repeated measurements, we found a significant increase in readers' sensitivity (P<0.001) without loss of specificity (P=0.855) with the effects being reader dependent (P<0.001). Sensitivities varied from 68% to 100% without CAD and from 76% to 100% with CAD. A 2-way analysis of variance showed a small but significant decrease in reading time (P<0.001), with the duration varying between 24 and 208 seconds without CAD and between 17 and 196 seconds with CAD, and a significant increase in readers' confidence scores using CAD as a concurrent reader (P<0.001).
Conclusions: CAD as a concurrent reader has the potential to increase readers' sensitivity and confidence with a decrease in reading time without loss of specificity. The differences between readers, however, require further evaluation of CAD as a concurrent reader in a larger trial before stronger conclusions can be drawn.
MeSH term(s) Acute Disease ; Angiography ; Diagnosis, Differential ; Female ; Humans ; Male ; Middle Aged ; Pulmonary Embolism/diagnostic imaging ; Radiographic Image Interpretation, Computer-Assisted/methods ; Retrospective Studies ; Sensitivity and Specificity ; Tomography, X-Ray Computed/methods
Language English
Publishing date 2013-09
Publishing country United States
Document type Journal Article ; Research Support, Non-U.S. Gov't
ZDB-ID 632900-7
ISSN 1536-0237 ; 0883-5993
ISSN (online) 1536-0237
ISSN 0883-5993
DOI 10.1097/RTI.0b013e3182870b97
Shelf mark
Zs.A 2187: Show issues Location:
Je nach Verfügbarkeit (siehe Angabe bei Bestand)
bis Jg. 1994: Bestellungen von Artikeln über das Online-Bestellformular
Jg. 1995 - 2021: Lesesall (1.OG)
ab Jg. 2022: Lesesaal (EG)
Database MEDical Literature Analysis and Retrieval System OnLINE

More links

Kategorien

To top