Article ; Online: Development of a novel low-pressure scintillation cell with ZnS(Ag)-coated clapboard for Rn-220 measurement.
2023 Volume 203, Page(s) 111107
Abstract: The high-precision measurement of Rn-220 is essential for assessing and preventing thoron radiological hazards. Prior research has revealed that employing a scintillation cell without a clapboard improves the detection efficiency for both Rn-222 and Rn- ... ...
Abstract | The high-precision measurement of Rn-220 is essential for assessing and preventing thoron radiological hazards. Prior research has revealed that employing a scintillation cell without a clapboard improves the detection efficiency for both Rn-222 and Rn-220 by reducing air pressure, and the Rn-220 calibration factor is established at an atmospheric pressure of 0.4. However, the decrease in air pressure leads to a corresponding reduction in Rn-220 concentrations within the scintillation cell, resulting in lower counts and larger statistical fluctuations. For the purpose of addressing this issue, a ZnS(Ag)-coated clapboard was added to the low-pressure scintillation cell for measuring Rn-222 and Rn-220. Several experiments were conducted in conjunction with Monte Carlo simulations. The results of these simulations, along with experiments using the standard radon chamber, provide valuable references for establishing the Rn-220 calibration factor. The experimental findings demonstrate that saturated detection efficiency of Rn-222 and Rn-220 can be maintained at below 0.7 atmospheric pressure. Therefore, the Rn-220 calibration factor, determined with the detection efficiency of 0.73 ± 0.04 at an atmospheric pressure of 0.7, was determined to be 31.98 ± 1.83 Bq·m |
---|---|
Language | English |
Publishing date | 2023-11-08 |
Publishing country | England |
Document type | Journal Article |
ZDB-ID | 1142596-9 |
ISSN | 1872-9800 ; 0883-2889 ; 0969-8043 |
ISSN (online) | 1872-9800 |
ISSN | 0883-2889 ; 0969-8043 |
DOI | 10.1016/j.apradiso.2023.111107 |
Database | MEDical Literature Analysis and Retrieval System OnLINE |
More links
Kategorien
In stock of ZB MED Cologne/Königswinter
Ue I Zs.279: Show issues | Location: Je nach Verfügbarkeit (siehe Angabe bei Bestand) bis Jg. 2021: Bestellungen von Artikeln über das Online-Bestellformular ab Jg. 2022: Lesesaal (EG) |
Order via subito
This service is chargeable due to the Delivery terms set by subito. Orders including an article and supplementary material will be classified as separate orders. In these cases, fees will be demanded for each order.