LIVIVO - Das Suchportal für Lebenswissenschaften

switch to English language
Erweiterte Suche

Ihre letzten Suchen

  1. AU="Renziehausen, Laura"
  2. AU="De Andrés-Laguillo, Macarena"
  3. AU="Sheila V. Kusnoor"
  4. AU="Aydoğdu, İsmet"
  5. AU=Fried Jonathan E
  6. AU="April C. Roslani"
  7. AU="Scott, Jeffrey F"
  8. AU=Piscaglia Anna Chiara AU=Piscaglia Anna Chiara
  9. AU="Ziya Bozkurt"
  10. AU="Morris, Michael A."
  11. AU="Low, Keat"
  12. AU="Zick, G."
  13. AU=Miles Alexander
  14. AU="Orzan, Fulvio"
  15. AU="Shruti A. Anant"
  16. AU="Jin, Hong-Wei"
  17. AU="Gonzalez, Louis"
  18. AU=Torres Victor J.
  19. AU="Manning, Nyla"
  20. AU="Sindkar, Anushka"
  21. AU=Rodieux Frdrique
  22. AU="Tote, Sachin"

Suchergebnis

Treffer 1 - 1 von insgesamt 1

Suchoptionen

Artikel ; Online: The Influence of Positive End-Expiratory Pressure on Leakage and Oxygenation Using a Laryngeal Mask Airway: A Randomized Trial.

Ullmann, Hannah / Renziehausen, Laura / Geil, Dominik / Sponholz, Christoph / Thomas-Rüddel, Daniel / Völker, Maria Theresa / Pietsch, Uta / Krug, Natalie / Bercker, Sven

Anesthesia and analgesia

2022  Band 135, Heft 4, Seite(n) 769–776

Abstract: Background: The value of positive end-expiratory pressure (PEEP) in maintaining oxygenation during ventilation with a laryngeal mask airway (LMA) mask is unclear. To clarify the potential benefit or harm to PEEP application during positive pressure ... ...

Abstract Background: The value of positive end-expiratory pressure (PEEP) in maintaining oxygenation during ventilation with a laryngeal mask airway (LMA) mask is unclear. To clarify the potential benefit or harm to PEEP application during positive pressure ventilation with a ProSeal LMA® mask, we compared the effect of PEEP versus zero end-expiratory pressure (ZEEP) on gas leakage and oxygenation. We hypothesized that a PEEP of 8 mbar (8.2 cm H 2 O) would be associated with an increased incidence of gas leakage compared to ZEEP.
Methods: We designed a prospective, controlled, randomized, single-blinded, multicenter clinical trial. Patients >18 years of age with an American Society of Anesthesiologists (ASA) physical status I/II without increased risk of aspiration were enrolled if they were scheduled for elective surgery under general anesthesia with an LMA mask. Patients were randomized to a control group managed with ZEEP or an intervention group managed with a PEEP of 8 mbar. Both groups received positive pressure ventilation. The primary end point was the occurrence of gas leakage. The Student t test and χ 2 test were used for statistical analysis.
Results: A total of 174 patients were enrolled in the ZEEP group, and 208 were enrolled in the PEEP group. The incidence of gas leakage did not differ between the 2 groups (ZEEP: 23/174, 13.2%; PEEP: 42/208, 20.2%; P = .071; odds ratio [OR], 1.611; 95% confidence interval [CI], 0.954-2.891). However, more patients required reseating of the LMA mask in the PEEP group (ZEEP: 5/174, 2.9%; PEEP: 18/208, 8.7%; P = .018; OR, 3.202; 95% CI, 1.164-8.812). The need for endotracheal intubation did not differ between groups (ZEEP: 2/174, 1.1%; PEEP: 7/208, 3.4%; P = .190; OR, 2.995; 95% CI, 0.614-14.608). After positive pressure ventilation for 25 minutes, the mean peripheral oxygen saturation (Sp o2 ) was higher in the PEEP than in the ZEEP group (98.5 [1.9]% vs 98.0 [1.4]%; P = .01). Peak inspiratory pressure (PIP; 16 [2] vs 12 [4] mbar; P < .001) and dynamic compliance (57 [14] vs 49 [14] mL/mbar; P < .001) were both higher in the PEEP group than in the ZEEP group.
Conclusions: Use of PEEP did not affect the overall incidence of gas leakage. However, PEEP did result in a higher incidence of attempts to reseat the LMA mask compared to ZEEP, whereas the incidence of rescue intubation did not differ between groups. We concluded that a PEEP of 8 mbar did not increase overall gas leakage during positive pressure ventilation with an LMA mask, but it did slightly improve gas exchange and compliance. Overall, our study does not provide strong arguments for using PEEP during ventilation with an LMA mask in elective surgery.
Mesh-Begriff(e) Anesthesia, General/adverse effects ; Humans ; Laryngeal Masks/adverse effects ; Positive-Pressure Respiration/adverse effects ; Prospective Studies ; Respiration, Artificial
Sprache Englisch
Erscheinungsdatum 2022-06-20
Erscheinungsland United States
Dokumenttyp Journal Article ; Multicenter Study ; Randomized Controlled Trial
ZDB-ID 80032-6
ISSN 1526-7598 ; 0003-2999
ISSN (online) 1526-7598
ISSN 0003-2999
DOI 10.1213/ANE.0000000000006115
Signatur
Uk I Zs.78: Hefte anzeigen Standort:
Je nach Verfügbarkeit (siehe Angabe bei Bestand)
bis Jg. 2021: Bestellungen von Artikeln über das Online-Bestellformular
ab Jg. 2022: Lesesaal (EG)
Zs.MO 149: Hefte anzeigen
Datenquelle MEDical Literature Analysis and Retrieval System OnLINE

Zusatzmaterialien

Kategorien

Zum Seitenanfang