Artikel: Multiparametric optimization of a reheated organic Rankine cycle for waste heat recovery based repowering of a degraded combined cycle gas turbine power plant

Reshaeel, Muhammad / Javed, Adeel / Jamil, Ahmad / Ali, Majid / Mahmood, Mariam / Waqas, Adeel

Energy conversion and management. 2022 Feb. 15, v. 254

2022  

Abstract: The study has conducted multiparametric optimization of a newly modified double stage reheated organic Rankine cycle configuration for the objective function of specific work output and its comparison with other conventional configurations of the organic ...

Abstract The study has conducted multiparametric optimization of a newly modified double stage reheated organic Rankine cycle configuration for the objective function of specific work output and its comparison with other conventional configurations of the organic Rankine cycle for the waste heat recovery-based repowering of a degraded combined cycle gas turbine power plant using R245fa, R113, and R141b as the working fluids. Thermodynamic performance of the triple cycle formed by integrating each organic Rankine cycle configuration with the combined cycle gas turbine unit is assessed in terms of repowering, specific fuel consumption and specific water consumption along with the associated greenhouse gas emissions. 24-hour performance variation of the combined cycle gas turbine unit has been incorporated in the analysis. It is found that the double stage reheated organic Rankine cycle configuration has outperformed other configurations in terms of thermodynamic performance. Triple cycle for the double stage reheated organic Rankine cycle has resulted in an average of 1.37% increase in net power output for the working fluid R141b, equivalent to 5.10 MW of additional power output. The thermal efficiency of the triple cycle for double stage reheated organic Rankine cycle has increased by 1.40%, whereas the specific fuel consumption and specific water consumption have reduced by 1.28% and 3.35%, respectively using R141b as the working fluid. The highest waste heat recovery potential is exhibited by the integrated basic organic Rankine cycle configuration for the working fluid R245fa, recovering 30,840 kW of waste heat, equivalent to the burning of 2467.2 kg/hr of CH₄ and 6784.7 kg/hr CO₂ emissions.
Schlagwörter administrative management ; carbon dioxide ; energy conversion ; energy use and consumption ; greenhouse gases ; power plants ; waste heat recovery
Sprache Englisch
Erscheinungsverlauf 2022-0215
Erscheinungsort Elsevier Ltd
Dokumenttyp Artikel
ZDB-ID 2000891-0
ISSN 0196-8904
ISSN 0196-8904
DOI 10.1016/j.enconman.2022.115237
Datenquelle NAL Katalog (AGRICOLA)