LIVIVO - The Search Portal for Life Sciences

zur deutschen Oberfläche wechseln
Advanced search

Search results

Result 1 - 10 of total 109

Search options

  1. Article: ÖGP 2021/Fall des Jahres: Kleiner Herd mit großer Wirkung?

    Auer, M. / Errhalt, P. / Riegler, W.

    Universum Innere Medizin

    2022  Volume -, Issue 3, Page(s) 60

    Language German
    Document type Article
    ZDB-ID 2475266-6
    ISSN 1607-8861
    Database Current Contents Medicine

    More links

    Kategorien

  2. Article ; Online: Knowledge management from an ancient Chinese point of view, or the knowledge flow through an organisation

    Riegler, Werner

    I-KNOW '07 : 7th International Conference on Knowledge Management ; [conference proceedings ; as a part of TRIPLE-I 2007 ; Graz, Austria, September 5 - 7, 2007] , p. 217-224

    2007  , Page(s) 217–224

    Author's details Werner Riegler
    Language English
    Size Online-Ressource, Ill., graph. Darst.
    Publisher Verl. der Techn. Univ. ] [u.a.]
    Publishing place [Graz
    Document type Article ; Online
    Note IMD-Felder maschinell generiert
    Database ECONomics Information System

    More links

    Kategorien

  3. Book ; Online: Studying signals in particle detectors with resistive elements such as the 2D resistive strip bulk MicroMegas

    Janssens, Djunes / Brunbauer, Florian / Flöthner, Karl Jonathan / Lisowska, Marta / Muller, Hans / Oliveri, Eraldo / Orlandini, Giorgio / Riegler, Werner / Ropelewski, Leszek / Schindler, Heinrich / Scharenberg, Lucian / Utrobicic, Antonija / Veenhof, Rob

    2023  

    Abstract: As demonstrated by the ATLAS New Small Wheel community with their MicroMegas (MM) design, resistive electrodes are now used in different detector types within the Micro Pattern Gaseous Detector family to improve their robustness or performance. The ... ...

    Abstract As demonstrated by the ATLAS New Small Wheel community with their MicroMegas (MM) design, resistive electrodes are now used in different detector types within the Micro Pattern Gaseous Detector family to improve their robustness or performance. The extended form of the Ramo-Shockley theorem for conductive media has been applied to a 1 M$\Omega$/$\Box$ 2D resistive strip bulk MM to calculate the signal's spreading over neighbouring channels using an 80 GeV/c muon track. For this geometry, the dynamic weighting potential was obtained numerically using a finite element solver by applying a junction condition and coordinate scaling technique to accurately represent the boundary conditions of a $10\times 10$ cm$^2$ active area. Using test beam measurements, the results of this model will be used to benchmark this microscopic modelling methodology for signal induction in resistive particle detectors.

    Comment: There are 6 pages and 4 figures. Proceeding for the 7th International Conference on Micro-Pattern Gaseous Detectors, 11-16 December 2022, Rehovot, Israel
    Keywords Physics - Instrumentation and Detectors
    Subject code 621
    Publishing date 2023-04-04
    Publishing country us
    Document type Book ; Online
    Database BASE - Bielefeld Academic Search Engine (life sciences selection)

    More links

    Kategorien

  4. Book ; Thesis: Möglichkeiten der Energiespeicherung mit Latentspeichern

    Riegler, W

    (Schriftenreihe der Energieforschungsgemeinschaft im Verband der E-Werke Österreichs)

    1995  

    Author's details W. Riegler
    Series title Schriftenreihe der Energieforschungsgemeinschaft im Verband der E-Werke Österreichs
    Language German
    Size XIV, 148 S, Ill., graph. Darst, 30 cm
    Publisher VEÖ, Verband der Elektrizitätswerke Österreichs
    Publishing place Wien
    Document type Book ; Thesis
    Thesis / German Habilitation thesis Techn. Univ., Diplomarbeit--Graz
    ISBN 390141116X ; 9783901411168
    Database Library catalogue of the German National Library of Science and Technology (TIB), Hannover

    More links

    Kategorien

  5. Article ; Online: Diagnostic accuracy of two commercially available rapid assays for detection of IgG and IgM antibodies to SARS-CoV-2 compared to ELISA in a low-prevalence population ; Diagnostische Leistungsbeurteilung zweier kommerziell erhältlicher Schnelltests zum Nachweis von IgG und IgM Antikörper gegen SARS-CoV-2 im Vergleich zu ELISA in einer niedrigprävalenz-Population

    Hackner, K / Errhalt, P / Willheim, M / Schragel, F / Grasl, MA / Lagumdzija, J / Riegler, W / Ecker, M / Wechdorn, M / Thalhammer, F / Assadian, O

    GMS Hygiene and Infection Control; VOL: 15; DOC28 /20201111/

    2020  

    Abstract: Background: New commercially available point-of-care (POC) immunodiagnostic tests are appearing, which may yield rapid results for anti-SARS-CoV-2 antibodies. The aim of this study was to evaluate the diagnostic accuracy of rapid antibody detection tests ...

    Abstract Background: New commercially available point-of-care (POC) immunodiagnostic tests are appearing, which may yield rapid results for anti-SARS-CoV-2 antibodies. The aim of this study was to evaluate the diagnostic accuracy of rapid antibody detection tests compared to a validated laboratory-based enzyme-linked immunosorbent assay (ELISA) and to investigate infections amongst healthcare workers (HCWs) after unprotected close contact to COVID-19 patients. Methods: Blood serum and whole blood of 130 participants were tested with NADAL® COVID-19 IgG/IgM rapid test and mö-screen 2019-NCOV coronavirus test against a validated ELISA test. Infection status was evaluated using real-time polymerase-chain-reaction.Results: Acute COVID-19 infection was detected in 2.4% of exposed HCWs. Antibody tests showed an overall frequency of IgG and IgM in 5.3%, with 1.6% asymptomatic infections. The NADAL® test showed a sensitivity (IgM/IgG) of 100% (100%/100%), a specificity (IgM/IgG) of 98.8% (97.6%/100 %), a PPV of 76.9% (57.1%/100%), an NPV of 100% (100%/100%), and a diagnostic accuracy of 98.8% (97.7%/100%). The mö-screen test had a sensitivity (IgM/IgG) of 90.9% (80%/100%), a specificity (IgM/IgG) of 98.8% (97.6%/100%), a PPV of 76.9% (57.1%/100%), an NPV of 99.6% (99.2%/100%), and a diagnostic accuracy of 98.5% (96.9%/100%). Conclusions: The frequency of COVID-19 infections in HCWs after unprotected close contact is higher than in the general population of a low-prevalence country. Both POC tests were useful for detecting IgG, but did not perform well for IgM, mainly due to false positive results.

    Hintergrund: Es erscheinen neue im Handel erhältliche immundiagnostische Point-of-Care-Tests (POC), die schnelle Ergebnisse für Anti-SARS-CoV-2-Antikörper liefern können. Ziel dieser Studie war es, die diagnostische Leistungsfähigkeit von Schnelltests zum Nachweis von Antikörpern im Vergleich zu einem validierten ELISA (Enzyme-Linked Immunosorbent Assay) zu bewerten und Infektionen bei Beschäftigten im Gesundheitswesen nach ungeschütztem engen Kontakt mit COVID-19-Patienten zu detektieren.Methoden: Blutserum und Vollblut von 130 Teilnehmern wurden mit dem NADAL® COVID-19 IgG/IgM-Schnelltest und dem Mö-screen 2019-NCOV Coronavirus-Test gegen einen validierten ELISA-Test untersucht. Der Infektionsstatus wurde unter Verwendung einer Echtzeit-Polymerase-Kettenreaktion (RT-PCR) bewertet.Ergebnisse: Eine akute COVID-19-Infektion wurde bei 2,4% der exponierten Mitarbeiterinnen festgestellt. Antikörpertests zeigten eine Gesamthäufigkeit von IgG und IgM in 5,3% bei 1,6% asymptomatischen Infektionen. Der NADAL®-Test zeigte eine Sensitivität (IgM/IgG) von 100% (100%/100%), eine Spezifität (IgM/IgG) von 98,8% (97,6%/100%), einen PPV von 76,9% (57,1%/100%), ein NPV von 100% (100%/100%) und eine diagnostische Genauigkeit von 98,8% (97,7%/100%). Der Mö-Screen-Test hatte eine Sensitivität (IgM/IgG) von 90,9% (80%/100%), eine Spezifität (IgM/IgG) von 98,8% (97,6%/100%), einen PPV von 76,9% (57,1%/100%), ein Kapitalwert von 99,6% (99,2%/100%) und eine diagnostische Genauigkeit von 98,5% (96,9%/100%).Schlussfolgerung: Die Häufigkeit von COVID-19-Infektionen bei Mitarbeitern im Gesundheitswesen nach ungeschütztem engem Kontakt ist höher als in der Allgemeinbevölkerung eines Landes mit niedriger Prävalenz. Beide POC-Tests waren zum Nachweis von IgG nützlich, zeigten jedoch keine gute Leistungsfähigkeit für den Nachweis von IgM, hauptsächlich aufgrund falsch positiver Ergebnisse.
    Keywords COVID-19 ; anti-SARS-CoV2-antibodies ; ELISA ; point-of-care testing ; anti-SARS-CoV2-Antikörper ; point-of-care tests ; ddc: 610 ; covid19
    Language English
    Publishing date 2020-11-11
    Publisher German Medical Science GMS Publishing House; Düsseldorf
    Publishing country de
    Document type Article ; Online
    Database BASE - Bielefeld Academic Search Engine (life sciences selection)

    More links

    Kategorien

  6. Article ; Conference proceedings: Erfolgreiche endoskopische Lungenvolumenreduktion mittels Ventilen bei Patienten mit schwerstgradigem Lungenemphysem (FEV1 ≤20%/Soll)

    Riegler, W / Karpf-Wissel, R / Darwiche, K / Freitag, L

    Pneumologie

    2013  

    Abstract: Einleitung: Für COPD-Patienten mit schwerstgradigem Lungenemphysem (FEV1≤20%/Soll) gibt es wenig therapeutische Optionen. Die endoskopische Lungenvolumenreduktion (ELVR) ist eine Therapiealternative mit dem Ziel die deutlich eingeschränkte ... ...

    Event/congress 54. Kongress der DGP, Hannover, 2013
    Abstract Einleitung: Für COPD-Patienten mit schwerstgradigem Lungenemphysem (FEV1≤20%/Soll) gibt es wenig therapeutische Optionen. Die endoskopische Lungenvolumenreduktion (ELVR) ist eine Therapiealternative mit dem Ziel die deutlich eingeschränkte Lebensqualität zu verbessern. Wir präsentieren eine retrospektive Analyse über Änderungen der FEV1-Werte und der 6-Minuten-Gehstrecke nach Ventilimplantation bei diesen Patienten.
    Methode: An 12 Patienten (Alter 56 ± 5,8 Jahre, 58,3% männlich) mit einem FEV1≤20%/Soll erfolgte eine ELVR mittels Ventilimplantation. Die Auswahl der Patienten und der Zielsegmente erfolgte an Hand von Lungenfunktion, 6-Min-Gehtest, CT-Thorax, Perfusionsszintigrafie und Chartismessung. Die Änderungen der FEV1-Werte sowie der 6-Min-Gehstrecke nach 4 Wochen, 3 Monaten, 6 Monaten und 12 Monaten wurden verglichen.
    Ergebnisse: Klassische Zielzonen in der Perfusionsszintigrafie bei heterogen verteiltem Emphysem sahen wir in 10 Fällen. In einer Messung war keine, sechsmal eine leicht- bis mittelgradige und viermal eine hochgradige Kollateralventilation nachweisbar. Zweimal wurden Ventile in den linken Unterlappen gelegt, die restlichen 10 Eingriffe erfolgten im rechten und linken Oberlappen bzw. Lingula. Dabei erfolgte in 8 Fällen ein kompletter Lappenverschluss. 2 Patienten entwickelten eine Atelektase. 3 Monate nach Ventilimplantation zeigte sich eine Verbesserung der FEV1-Werte um 16,9 ± 38,4% (nach 6 Monaten 27,2 ± 51,7%). Die 6-Minuten-Gehstrecke besserte sich nach 3 Monaten um 15 ± 24,9% (nach 6 Monaten 30,7 ± 39,9%). Außer einem Pneumothorax traten keine weiteren Komplikationen auf.
    Zusammenfassung: In unserer retrospektiven Analyse zeigen wir, dass Patienten mit einer FEV1≤20%/Soll bei heterogen verteiltem Emphysem und vorliegenden Zielzonen in der Perfusionsszintigrafie von einer ELVR profitieren können auch wenn eine kollaterale Ventilation vorliegt und die Patienten keine Atelektase entwickeln.
    Language German
    Publishing date 2013-02-27
    Publishing place Stuttgart ; New York
    Document type Article ; Conference proceedings
    ZDB-ID 607630-0
    ISSN 1438-8790 ; 0934-8387
    ISSN (online) 1438-8790
    ISSN 0934-8387
    DOI 10.1055/s-0033-1334720
    Database Thieme publisher's database

    More links

    Kategorien

  7. Article: Diagnostic accuracy of two commercially available rapid assays for detection of IgG and IgM antibodies to SARS-CoV-2 compared to ELISA in a low-prevalence population.

    Hackner, Klaus / Errhalt, Peter / Willheim, Martin / Schragel, Felix / Grasl, Maria-Anna / Lagumdzija, Jasmina / Riegler, Waltraud / Ecker, Michael / Wechdorn, Matthias / Thalhammer, Florian / Assadian, Ojan

    GMS hygiene and infection control

    2020  Volume 15, Page(s) Doc28

    Abstract: Background: ...

    Abstract Background:
    Keywords covid19
    Language English
    Publishing date 2020-11-11
    Publishing country Germany
    Document type Journal Article
    ZDB-ID 2717852-3
    ISSN 2196-5226
    ISSN 2196-5226
    DOI 10.3205/dgkh000363
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  8. Article ; Online: Fever after bronchoscopy: serum procalcitonin enables early diagnosis of post-interventional bacterial infection.

    Hackner, Klaus / Riegler, Waltraud / Handzhiev, Sabin / Bauer, Rosemarie / Veres, Jan / Speiser, Manuela / Meisinger, Karin / Errhalt, Peter

    BMC pulmonary medicine

    2017  Volume 17, Issue 1, Page(s) 156

    Abstract: Background: The aim of this study was to differentiate unspecific and self-limiting fever after bronchoscopy from fever due to infection by using serum procalcitonin, C-reactive protein and neutrophil count. Furthermore, frequency of fever after ... ...

    Abstract Background: The aim of this study was to differentiate unspecific and self-limiting fever after bronchoscopy from fever due to infection by using serum procalcitonin, C-reactive protein and neutrophil count. Furthermore, frequency of fever after bronchoscopy and procedures as possible risk factors were evaluated.
    Methods: Three hundred and fourteen consecutive patients were included. All bronchoscopies were performed using jet-ventilation and general anesthesia. Patients were analyzed according to interventions performed during bronchoscopy and laboratory results. Microbiological assessment was done in patients who developed fever to prove or rule out a bacterial infection.
    Results: Forty-four patients showed fever within 24 h following bronchoscopy (14%). A bacterial infection was proven in 11 patients with fever (3.5%). Procalcitonin, neutrophil count and C-reactive protein were significantly higher in patients with fever after bronchoscopy compared to non-fever patients. To predict bacterial infection in the receiver operating analysis, procalcitonin had the highest area under the curve (0.942; 95% confidence interval [CI], 0.768 to 1.000; p = <0.001), followed by neutrophil count (AUC, 0.804; 95% CI, 0.606 to 0.946; p = 0.005), whereas CRP levels where not statistically significant. Endoscopic airway recanalization was the only intervention that induced fever more frequently than all other interventions (OR 13.629).
    Conclusions: Fever is frequently seen after bronchoscopy and in some cases caused by bacterial infection. Procalcitonin might be useful to distinguish a bacterial infection from unspecific self-limiting fever. Airway recanalization is a procedure that seems to induce fever significantly more often than other bronchoscopic interventions.
    MeSH term(s) Aged ; Bacterial Infections/diagnosis ; Bacterial Infections/etiology ; Biomarkers/analysis ; Bronchoalveolar Lavage Fluid/microbiology ; Bronchoscopy ; C-Reactive Protein/analysis ; Calcitonin/blood ; Early Diagnosis ; Female ; Fever of Unknown Origin/etiology ; Humans ; Leukocyte Count ; Male ; Middle Aged ; Prospective Studies ; ROC Curve ; Risk Factors
    Chemical Substances Biomarkers ; Calcitonin (9007-12-9) ; C-Reactive Protein (9007-41-4)
    Language English
    Publishing date 2017-11-28
    Publishing country England
    Document type Journal Article ; Observational Study
    ZDB-ID 2059871-3
    ISSN 1471-2466 ; 1471-2466
    ISSN (online) 1471-2466
    ISSN 1471-2466
    DOI 10.1186/s12890-017-0508-1
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  9. Article ; Online: Diagnostic accuracy of two commercially available rapid assays for detection of IgG and IgM antibodies to SARS-CoV-2 compared to ELISA in a low-prevalence population

    Hackner, Klaus / Errhalt, Peter / Willheim, Martin / Schragel, Felix / Grasl, Maria-Anna / Lagumdzija, Jasmina / Riegler, Waltraud / Ecker, Michael / Wechdorn, Matthias / Thalhammer, Florian / Assadian, Ojan

    GMS Hygiene and Infection Control

    2020  Volume 15, Page(s) 28

    Abstract: Hintergrund: Es erscheinen neue im Handel erhältliche immundiagnostische Point-of-Care-Tests (POC), die schnelle Ergebnisse für Anti-SARS-CoV-2-Antikörper liefern können. Ziel dieser Studie war es, die diagnostische Leistungsfähigkeit von Schnelltests ... ...

    Title translation Diagnostische Leistungsbeurteilung zweier kommerziell erhältlicher Schnelltests zum Nachweis von IgG und IgM Antikörper gegen SARS-CoV-2 im Vergleich zu ELISA in einer niedrigprävalenz-Population
    Abstract Hintergrund: Es erscheinen neue im Handel erhältliche immundiagnostische Point-of-Care-Tests (POC), die schnelle Ergebnisse für Anti-SARS-CoV-2-Antikörper liefern können. Ziel dieser Studie war es, die diagnostische Leistungsfähigkeit von Schnelltests zum Nachweis von Antikörpern im Vergleich zu einem validierten ELISA (Enzyme-Linked Immunosorbent Assay) zu bewerten und Infektionen bei Beschäftigten im Gesundheitswesen nach ungeschütztem engen Kontakt mit COVID-19-Patienten zu detektieren.
    Methoden: Blutserum und Vollblut von 130 Teilnehmern wurden mit dem NADAL® COVID-19 IgG/IgM-Schnelltest und dem Mö-screen 2019-NCOV Coronavirus-Test gegen einen validierten ELISA-Test untersucht. Der Infektionsstatus wurde unter Verwendung einer Echtzeit-Polymerase-Kettenreaktion (RT-PCR) bewertet.
    Ergebnisse: Eine akute COVID-19-Infektion wurde bei 2,4% der exponierten Mitarbeiterinnen festgestellt. Antikörpertests zeigten eine Gesamthäufigkeit von IgG und IgM in 5,3% bei 1,6% asymptomatischen Infektionen. Der NADAL®-Test zeigte eine Sensitivität (IgM/IgG) von 100% (100%/100%), eine Spezifität (IgM/IgG) von 98,8% (97,6%/100%), einen PPV von 76,9% (57,1%/100%), ein NPV von 100% (100%/100%) und eine diagnostische Genauigkeit von 98,8% (97,7%/100%). Der Mö-Screen-Test hatte eine Sensitivität (IgM/IgG) von 90,9% (80%/100%), eine Spezifität (IgM/IgG) von 98,8% (97,6%/100%), einen PPV von 76,9% (57,1%/100%), ein Kapitalwert von 99,6% (99,2%/100%) und eine diagnostische Genauigkeit von 98,5% (96,9%/100%).
    Schlussfolgerung: Die Häufigkeit von COVID-19-Infektionen bei Mitarbeitern im Gesundheitswesen nach ungeschütztem engem Kontakt ist höher als in der Allgemeinbevölkerung eines Landes mit niedriger Prävalenz. Beide POC-Tests waren zum Nachweis von IgG nützlich, zeigten jedoch keine gute Leistungsfähigkeit für den Nachweis von IgM, hauptsächlich aufgrund falsch positiver Ergebnisse. ; Background: New commercially available point-of-care (POC) immunodiagnostic tests are appearing, which may yield rapid results for anti-SARS-CoV-2 antibodies. The aim of this study was to evaluate the diagnostic accuracy of rapid antibody detection tests compared to a validated laboratory-based enzyme-linked immunosorbent assay (ELISA) and to investigate infections amongst healthcare workers (HCWs) after unprotected close contact to COVID-19 patients.
    Methods: Blood serum and whole blood of 130 participants were tested with NADAL® COVID-19 IgG/IgM rapid test and mö-screen 2019-NCOV coronavirus test against a validated ELISA test. Infection status was evaluated using real-time polymerase-chain-reaction.
    Results: Acute COVID-19 infection was detected in 2.4% of exposed HCWs. Antibody tests showed an overall frequency of IgG and IgM in 5.3%, with 1.6% asymptomatic infections. The NADAL® test showed a sensitivity (IgM/IgG) of 100% (100%/100%), a specificity (IgM/IgG) of 98.8% (97.6%/100 %), a PPV of 76.9% (57.1%/100%), an NPV of 100% (100%/100%), and a diagnostic accuracy of 98.8% (97.7%/100%). The mö-screen test had a sensitivity (IgM/IgG) of 90.9% (80%/100%), a specificity (IgM/IgG) of 98.8% (97.6%/100%), a PPV of 76.9% (57.1%/100%), an NPV of 99.6% (99.2%/100%), and a diagnostic accuracy of 98.5% (96.9%/100%).
    Conclusions: The frequency of COVID-19 infections in HCWs after unprotected close contact is higher than in the general population of a low-prevalence country. Both POC tests were useful for detecting IgG, but did not perform well for IgM, mainly due to false positive results.
    Keywords Medizin, Gesundheit ; COVID-19 ; anti-SARS-CoV2-antibodies ; ELISA ; point-of-care testing ; anti-SARS-CoV2-Antikörper ; point-of-care tests ; covid19
    Publishing date 2020-11-11
    Publisher German Medical Science GMS Publishing House; Düsseldorf
    Document type Article ; Online
    ZDB-ID 2717852-3
    ISSN 2196-5226 ; 2196-5226
    ISSN (online) 2196-5226
    ISSN 2196-5226
    DOI 10.3205/dgkh000363
    Database German Medical Science

    More links

    Kategorien

  10. Article ; Online: Diagnostic accuracy of two commercially available rapid assays for detection of IgG and IgM antibodies to SARS-CoV-2 compared to ELISA in a low-prevalence population

    Hackner, Klaus / Errhalt, Peter / Willheim, Martin / Schragel, Felix / Grasl, Maria-Anna / Lagumdzija, Jasmina / Riegler, Waltraud / Ecker, Michael / Wechdorn, Matthias / Thalhammer, Florian / Assadian, Ojan

    GMS Hygiene and Infection Control, Vol 15, p Doc

    2020  Volume 28

    Abstract: Background: New commercially available point-of-care (POC) immunodiagnostic tests are appearing, which may yield rapid results for anti-SARS-CoV-2 antibodies. The aim of this study was to evaluate the diagnostic accuracy of rapid antibody detection tests ...

    Abstract Background: New commercially available point-of-care (POC) immunodiagnostic tests are appearing, which may yield rapid results for anti-SARS-CoV-2 antibodies. The aim of this study was to evaluate the diagnostic accuracy of rapid antibody detection tests compared to a validated laboratory-based enzyme-linked immunosorbent assay (ELISA) and to investigate infections amongst healthcare workers (HCWs) after unprotected close contact to COVID-19 patients. Methods: Blood serum and whole blood of 130 participants were tested with NADAL COVID-19 IgG/IgM rapid test and mö-screen 2019-NCOV coronavirus test against a validated ELISA test. Infection status was evaluated using real-time polymerase-chain-reaction.Results: Acute COVID-19 infection was detected in 2.4% of exposed HCWs. Antibody tests showed an overall frequency of IgG and IgM in 5.3%, with 1.6% asymptomatic infections. The NADAL test showed a sensitivity (IgM/IgG) of 100% (100%/100%), a specificity (IgM/IgG) of 98.8% (97.6%/100 %), a PPV of 76.9% (57.1%/100%), an NPV of 100% (100%/100%), and a diagnostic accuracy of 98.8% (97.7%/100%). The mö-screen test had a sensitivity (IgM/IgG) of 90.9% (80%/100%), a specificity (IgM/IgG) of 98.8% (97.6%/100%), a PPV of 76.9% (57.1%/100%), an NPV of 99.6% (99.2%/100%), and a diagnostic accuracy of 98.5% (96.9%/100%). Conclusions: The frequency of COVID-19 infections in HCWs after unprotected close contact is higher than in the general population of a low-prevalence country. Both POC tests were useful for detecting IgG, but did not perform well for IgM, mainly due to false positive results.
    Keywords covid-19 ; anti-sars-cov2-antibodies ; elisa ; point-of-care testing ; Medicine ; R ; Public aspects of medicine ; RA1-1270 ; Microbiology ; QR1-502
    Language German
    Publishing date 2020-11-01T00:00:00Z
    Publisher German Medical Science GMS Publishing House
    Document type Article ; Online
    Database BASE - Bielefeld Academic Search Engine (life sciences selection)

    More links

    Kategorien

To top