Article ; Online: Mechanical Power Differs Between Pressure-Controlled Ventilation and Different Volume-Controlled Ventilation Modes.

Rietveld, Petra J / Snoep, Jacob W M / Lamping, Marjolein / van der Velde, Franciska / de Jonge, Evert / van Westerloo, David W / Schoe, Abraham

Critical care explorations

2022  Volume 4, Issue 8, Page(s) e0741

Abstract: Objectives: Mechanical power (MP) is a way of estimating the energy delivered by the ventilator to the patient. For both volume-controlled ventilation (VCV) and pressure-controlled ventilation (PCV) methods have been described to calculate the MP. The ... ...

Abstract Objectives: Mechanical power (MP) is a way of estimating the energy delivered by the ventilator to the patient. For both volume-controlled ventilation (VCV) and pressure-controlled ventilation (PCV) methods have been described to calculate the MP. The pressure-volume (PV) loop, from which the MP is calculated, is different for VCV compared with PCV. We aimed to compare the MP of VCV with zero pause time (VCV-0), VCV with 10% pause time (VCV-10), and PCV within patients in different patient categories based on severity of lung injury.
Design: In a proof-of-concept study, we enrolled 46 mechanically ventilated patients without spontaneous breathing efforts. Baseline measurements were done in pressure-controlled mode. Subsequently, measurements were done in VCV-0 and VCV-10. Tidal volume and all other settings were kept the same.
Setting: ICU, single university medical center.
Patients: Fifty-eight cases in 46 patients on controlled ventilation modes.
Interventions: Comparison between the MP of PCV, VCV-0, and VCV-10.
Measurement and main results: The mean MP of VCV-0, VCV-10, and PCV was 19.30, 21.80, and 20.87 J/min, respectively (
Conclusions: In patients ventilated in a controlled mode, VCV without pause time had the lowest MP followed by PCV. VCV with 10% pause time had the highest MP.