LIVIVO - The Search Portal for Life Sciences

zur deutschen Oberfläche wechseln
Advanced search

Search results

Result 1 - 3 of total 3

Search options

  1. Article ; Online: Comparison of Refractive Index Matching Techniques and PLIF40 Measurements in Annular Flow.

    Rivera, Yago / Bascou, Dorian / Blanco, David / Álvarez-Piñeiro, Lucas / Berna, César / Muñoz-Cobo, José-Luis / Escrivá, Alberto

    Sensors (Basel, Switzerland)

    2024  Volume 24, Issue 7

    Abstract: This paper investigates non-invasive techniques for annular two-phase flow analysis, focusing on liquid film characterization to understand the interfacial phenomena that are crucial for heat and mass transfer. Limited methods allow the study of the ... ...

    Abstract This paper investigates non-invasive techniques for annular two-phase flow analysis, focusing on liquid film characterization to understand the interfacial phenomena that are crucial for heat and mass transfer. Limited methods allow the study of the temporal and spatial evolution of liquid film, such as Planar Laser-Induced Fluorescence (PLIF). However, this method possesses optical challenges, leading to the need for improved techniques to mitigate refraction and reflection, such as Refractive Index Matching (RIM). This study utilizes an experimental annular flow facility to analyze both RIM and non-RIM PLIF over a range of liquid Reynolds numbers from 4200 to 10,400. Three configurations-PLIF RIM90, PLIF RIM40, and PLIF nRIM40-are compared from both qualitative and quantitative perspectives. In the quantitative analysis, key variables of the liquid film are measured, namely mean film thickness, disturbance wave height, and frequency. Variations in the analyzed variables indicate minor deviations, which are not likely to be caused by the technique used. However, all three methodologies exhibited errors that are estimated to be within a maximum of 10%, with a mean value of approximately 8%.
    Language English
    Publishing date 2024-04-05
    Publishing country Switzerland
    Document type Journal Article
    ZDB-ID 2052857-7
    ISSN 1424-8220 ; 1424-8220
    ISSN (online) 1424-8220
    ISSN 1424-8220
    DOI 10.3390/s24072317
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  2. Article ; Online: A Comparative Analysis of Conductance Probes and High-Speed Camera Measurements for Interfacial Behavior in Annular Air-Water Flow.

    Rivera, Yago / Bidon, Maxime / Muñoz-Cobo, José-Luis / Berna, Cesar / Escrivá, Alberto

    Sensors (Basel, Switzerland)

    2023  Volume 23, Issue 20

    Abstract: Different techniques are used to analyze annular flow, but the more interesting ones are those techniques that do not perturb the flow and provide enough resolution to clearly distinguish the interfacial phenomena that take place at the interface, ... ...

    Abstract Different techniques are used to analyze annular flow, but the more interesting ones are those techniques that do not perturb the flow and provide enough resolution to clearly distinguish the interfacial phenomena that take place at the interface, especially the disturbance waves (DW) and the ripple waves (DW). The understanding of these events is important because it influences the heat and mass transfer taking place through the thin film formed near the walls in this flow regime. The laser-induced fluorescence (LIF) and the three-electrode conductance probe are two commonly used techniques to study experimentally annular flow phenomena. In this paper, a set of experiments at different temperatures of 20 °C, 30 °C and 40 °C and different liquid Reynolds numbers have been performed in the annular flow regime, the characteristic of the DW and RW as average height and frequency of these waves has been measured by both techniques LIF and conductance probes. In addition, we also measured the mean film thickness. It was found that the mean film thickness and the DW height are practically the same when measured by both techniques; however, the height of the RW is smaller when measured by the conductance probe and this difference diminishes when the temperature increases.
    Language English
    Publishing date 2023-10-21
    Publishing country Switzerland
    Document type Journal Article
    ZDB-ID 2052857-7
    ISSN 1424-8220 ; 1424-8220
    ISSN (online) 1424-8220
    ISSN 1424-8220
    DOI 10.3390/s23208617
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  3. Article ; Online: Analysis of Conductance Probes for Two-Phase Flow and Holdup Applications.

    Muñoz-Cobo, José-Luis / Rivera, Yago / Berna, Cesar / Escrivá, Alberto

    Sensors (Basel, Switzerland)

    2020  Volume 20, Issue 24

    Abstract: In this paper we perform an analysis of the conductance probes used in two-phase flow applications especially for two-phase flow tomography of annular flow, to measure the waves produced in the interface with different boundary conditions without ... ...

    Abstract In this paper we perform an analysis of the conductance probes used in two-phase flow applications especially for two-phase flow tomography of annular flow, to measure the waves produced in the interface with different boundary conditions without perturbing the flow, and in addition we examine the holdup applications as measuring the average void fraction in a given region. The method used to obtain the detector conductance between the electrodes is to solve analytically the generalized Laplace equation in 3D with the boundary conditions of the problem, and then to obtain the average potential difference between the detector electrodes. Then, dividing the current intensity circulating between the emitter and the receiver electrodes by the average potential difference yields the probe conductance, which depends on the geometric and physical characteristics of the measured system and the probe. This conductance is then non-dimensionalized by dividing by the conductance of the pipe full of water. In this way a set of analytical expression have been obtained for the conductance of two-plate sensors with different geometries and locations. We have performed an exhaustive comparison of the results obtained using the equations deduced in this paper with the experimental data from several authors in different cases with very good agreement. In some cases when the distribution of bubbles is not homogeneous, we have explored the different alternatives of the effective medium theory (EMT) in terms of the self-consistent EMT and the non-consistent EMT.
    Language English
    Publishing date 2020-12-09
    Publishing country Switzerland
    Document type Journal Article
    ZDB-ID 2052857-7
    ISSN 1424-8220 ; 1424-8220
    ISSN (online) 1424-8220
    ISSN 1424-8220
    DOI 10.3390/s20247042
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

To top