LIVIVO - The Search Portal for Life Sciences

zur deutschen Oberfläche wechseln
Advanced search

Search results

Result 1 - 8 of total 8

Search options

  1. Article ; Online: Characterization of Gelatin-Polycaprolactone Membranes by Electrospinning.

    Rodríguez-Martín, Manuel / Aguilar, José Manuel / Castro-Criado, Daniel / Romero, Alberto

    Biomimetics (Basel, Switzerland)

    2024  Volume 9, Issue 2

    Abstract: New advances in materials science and medicine have enabled the development of new and increasingly sophisticated biomaterials. One of the most widely used biopolymers is polycaprolactone (PCL) because it has properties suitable for biomedical ... ...

    Abstract New advances in materials science and medicine have enabled the development of new and increasingly sophisticated biomaterials. One of the most widely used biopolymers is polycaprolactone (PCL) because it has properties suitable for biomedical applications, tissue engineering scaffolds, or drug delivery systems. However, PCL scaffolds do not have adequate bioactivity, and therefore, alternatives have been studied, such as mixing PCL with bioactive polymers such as gelatin, to promote cell growth. Thus, this work will deal with the fabrication of nanofiber membranes by means of the electrospinning technique using PCL-based solutions (12 wt.% and 20 wt.%) and PCL with gelatin (12 wt.% and 8 wt.%, respectively). Formic acid and acetic acid, as well as mixtures of both in different proportions, have been used to prepare the preliminary solutions, thus supporting the electrospinning process by controlling the viscosity of the solutions and, therefore, the size and uniformity of the fibers. The physical properties of the solutions and the morphological, mechanical, and thermal properties of the membranes were evaluated. Results demonstrate that it is possible to achieve the determined properties of the samples with an appropriate selection of polymer concentrations as well as solvents.
    Language English
    Publishing date 2024-01-25
    Publishing country Switzerland
    Document type Journal Article
    ISSN 2313-7673
    ISSN (online) 2313-7673
    DOI 10.3390/biomimetics9020070
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  2. Article: Surrogate metamodels from digital image correlation for testing high-performance composite vessels.

    Pisonero, Javier / Rodríguez-Martín, Manuel / Fueyo, Jose G / González-Aguilera, Diego / García-Martín, Roberto

    Heliyon

    2024  Volume 10, Issue 8, Page(s) e29525

    Abstract: In this work, a workflow has been developed for the generation of surrogate metamodels to predict and evaluate failure with a confidence above 95 % in initial service conditions of high-performance cylindrical vessels manufactured in composites by Roll ... ...

    Abstract In this work, a workflow has been developed for the generation of surrogate metamodels to predict and evaluate failure with a confidence above 95 % in initial service conditions of high-performance cylindrical vessels manufactured in composites by Roll Wrapping technology. Currently, there is no specific testing standardization for this type of vessel and to fill this gap probabilistic numerical models were developed, performed by the Finite Element Method, fed with the material characteristics obtained experimentally by 2D digital image correlation from flat specimens. From the initial numerical model, a surrogate metamodel was generated by stochastic approximations. Once the metamodels were obtained by robust engineering, an experimental ring-ring tensile test was developed under service conditions and deformations were measured by high-precision 3D digital image correlation. Parametric and robust tests showed that the results of the metamodel did not show statistically significant differences, with errors in the rupture part of less than 2 % with respect to the results obtained in the test, being proposed as a basis for new test procedures.
    Language English
    Publishing date 2024-04-12
    Publishing country England
    Document type Journal Article
    ZDB-ID 2835763-2
    ISSN 2405-8440
    ISSN 2405-8440
    DOI 10.1016/j.heliyon.2024.e29525
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  3. Article: Design of a Didactical Activity for the Analysis of Uncertainties in Thermography through the Use of Robust Statistics as Teacher-Oriented Approach

    Rodríguez-Gonzálvez, Pablo / Rodríguez-Martín, Manuel

    Remote Sensing. 2021 Jan. 24, v. 13, no. 3

    2021  

    Abstract: The thermography as a methodology to quantitative data acquisition is not usually addressed in the degrees of university programs. The present manuscript proposes a novel approach for the acquisition of advanced competences in engineering courses ... ...

    Abstract The thermography as a methodology to quantitative data acquisition is not usually addressed in the degrees of university programs. The present manuscript proposes a novel approach for the acquisition of advanced competences in engineering courses associated with the use of thermographic images via free/open-source software solutions. This strategy is established from a research based on the statistical and three-dimensional visualization techniques over thermographic imagery to improve the interpretation and comprehension of the different sources of error affecting the measurements and, thereby, the conclusions and analysis arising from them. The novelty is focused on the detection of non-normalities in thermographic images, which is illustrates in the experimental section. Additionally, the specific workflow for the generation of learning material related with this aim is raised for asynchronous and e-learning programs. These virtual materials can be easily deployed in an institutional learning management system, allowing the students to work with the models by means of free/open-source solutions easily. Subsequently, the present approach will give new tools to improve the application of professional techniques, will improve the students’ critical sense to know how to interpret the uncertainties in thermography using a single thermographic image, therefore they will be better prepared to face future challenges with more critical thinking.
    Keywords computer software ; data collection ; electronic learning ; management systems ; thermography
    Language English
    Dates of publication 2021-0124
    Publishing place Multidisciplinary Digital Publishing Institute
    Document type Article
    Note NAL-AP-2-clean
    ZDB-ID 2513863-7
    ISSN 2072-4292
    ISSN 2072-4292
    DOI 10.3390/rs13030402
    Database NAL-Catalogue (AGRICOLA)

    More links

    Kategorien

  4. Article ; Online: Suitability of Automatic Photogrammetric Reconstruction Configurations for Small Archaeological Remains.

    Rodríguez-Martín, Manuel / Rodríguez-Gonzálvez, Pablo

    Sensors (Basel, Switzerland)

    2020  Volume 20, Issue 10

    Abstract: Three-dimensional (3D) reconstruction is a useful technique for the documentation, characterization, and evaluation of small archeological objects. In this research, a comparison among different photogrammetric setups that use different lenses (macro and ...

    Abstract Three-dimensional (3D) reconstruction is a useful technique for the documentation, characterization, and evaluation of small archeological objects. In this research, a comparison among different photogrammetric setups that use different lenses (macro and standard zoom) and dense point cloud generation calibration processes for real specific objects of archaeological interest with different textures, geometries, and materials is raised using an automated data collection. The data acquisition protocol is carried out from a platform with control points referenced with a metrology absolute arm to accurately define a common spatial reference system. The photogrammetric reconstruction is performed considering a camera pre-calibration as well as a self-calibration. The latter is common for most data acquisition situations in archaeology. The results for the different lenses and calibration processes are compared based on a robust statistical analysis, which entails the estimation of both standard Gaussian and non-parametric estimators, to assess the accuracy potential of different configurations. As a result, 95% of the reconstructed points show geometric discrepancies lower than 0.85 mm for the most unfavorable case and less than 0.35 mm for the other cases.
    Language English
    Publishing date 2020-05-22
    Publishing country Switzerland
    Document type Journal Article
    ZDB-ID 2052857-7
    ISSN 1424-8220 ; 1424-8220
    ISSN (online) 1424-8220
    ISSN 1424-8220
    DOI 10.3390/s20102936
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  5. Article ; Online: Comprehensive Generation of Historical Construction CAD Models from Data Provided by a Wearable Mobile Mapping System: A Case Study of the Church of Adanero (Ávila, Spain).

    Rodríguez-Martín, Manuel / Sánchez-Aparicio, Luis Javier / Maté-González, Miguel Ángel / Muñoz-Nieto, Ángel Luis / Gonzalez-Aguilera, Diego

    Sensors (Basel, Switzerland)

    2022  Volume 22, Issue 8

    Abstract: This paper presents the results of a complex three-dimensional reconstruction of the church of Nuestra Señora de la Asunción (Ávila, Spain) as an example of a successful process of verticalization from point clouds to a comprehensive computer-aided ... ...

    Abstract This paper presents the results of a complex three-dimensional reconstruction of the church of Nuestra Señora de la Asunción (Ávila, Spain) as an example of a successful process of verticalization from point clouds to a comprehensive computer-aided design (CAD) model. The reconstruction was carried out using the novel and advanced wearable mobile mapping system ZEB-REVO in combination with a lifting pole, in order to cover the whole geometry of the temple and, also, to model the different constructive elements. To this end, a set of good practices was followed, which allowed for passing from reality to the CAD model, such as the use of closed loops or even the use of different parametric and non-parametric strategies to capture the real geometry of the elements. As a result, this paper outlines the main guidelines for passing from point clouds to comprehensive CAD models, the former being useful for the application of smart preventive conservation processes, heritage building information models or even advanced numerical simulations.
    MeSH term(s) Computer-Aided Design ; Spain ; Wearable Electronic Devices
    Language English
    Publishing date 2022-04-11
    Publishing country Switzerland
    Document type Journal Article
    ZDB-ID 2052857-7
    ISSN 1424-8220 ; 1424-8220
    ISSN (online) 1424-8220
    ISSN 1424-8220
    DOI 10.3390/s22082922
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  6. Article: Validation of Portable Mobile Mapping System for Inspection Tasks in Thermal and Fluid–Mechanical Facilities

    Rodríguez-Martín, Manuel / Rodríguez-Gonzálvez, Pablo / Ruiz de Oña Crespo, Esteban / González-Aguilera, Diego

    Remote Sensing. 2019 Sept. 20, v. 11, no. 19

    2019  

    Abstract: The three-dimensional registration of industrial facilities has a great importance for maintenance, inspection, and safety tasks and it is a starting point for new improvements and expansions in the industrial facilities context. In this paper, a ... ...

    Abstract The three-dimensional registration of industrial facilities has a great importance for maintenance, inspection, and safety tasks and it is a starting point for new improvements and expansions in the industrial facilities context. In this paper, a comparison between the results obtained using a novel portable mobile mapping system (PMMS) and a static terrestrial laser scanner (TLS), widely used for 3D reconstruction in civil and industrial scenarios, is carried out. This comparison is performed in the context of industrial inspection tasks, specifically in the thermal and fluid-mechanics facilities in a hospital. The comparison addresses the general reconstruction of a machine room, focusing on the quantitative and qualitative analysis of different elements (e.g., valves, regulation systems, burner systems and tanks, etc.). The validation of the PMMS is provided considering the TLS as ground truth and applying a robust statistical analysis. Results come to confirm the suitability of the PMMS to perform inspection tasks in industrial facilities.
    Keywords fluid mechanics ; hospitals ; qualitative analysis ; remote sensing ; scanners ; statistical analysis ; tanks
    Language English
    Dates of publication 2019-0920
    Publishing place Multidisciplinary Digital Publishing Institute
    Document type Article
    ZDB-ID 2513863-7
    ISSN 2072-4292
    ISSN 2072-4292
    DOI 10.3390/rs11192205
    Database NAL-Catalogue (AGRICOLA)

    More links

    Kategorien

  7. Article: A Novel Approach for the Shape Characterisation of Non-Melanoma Skin Lesions Using Elliptic Fourier Analyses and Clinical Images.

    Courtenay, Lloyd A / Barbero-García, Inés / Aramendi, Julia / González-Aguilera, Diego / Rodríguez-Martín, Manuel / Rodríguez-Gonzalvez, Pablo / Cañueto, Javier / Román-Curto, Concepción

    Journal of clinical medicine

    2022  Volume 11, Issue 15

    Abstract: The early detection of Non-Melanoma Skin Cancer (NMSC) is crucial to achieve the best treatment outcomes. Shape is considered one of the main parameters taken for the detection of some types of skin cancer such as melanoma. For NMSC, the importance of ... ...

    Abstract The early detection of Non-Melanoma Skin Cancer (NMSC) is crucial to achieve the best treatment outcomes. Shape is considered one of the main parameters taken for the detection of some types of skin cancer such as melanoma. For NMSC, the importance of shape as a visual detection parameter is not well-studied. A dataset of 993 standard camera images containing different types of NMSC and benign skin lesions was analysed. For each image, the lesion boundaries were extracted. After an alignment and scaling, Elliptic Fourier Analysis (EFA) coefficients were calculated for the boundary of each lesion. The asymmetry of lesions was also calculated. Then, multivariate statistics were employed for dimensionality reduction and finally computational learning classification was employed to evaluate the separability of the classes. The separation between malignant and benign samples was successful in most cases. The best-performing approach was the combination of EFA coefficients and asymmetry. The combination of EFA and asymmetry resulted in a balanced accuracy of 0.786 and an Area Under Curve of 0.735. The combination of EFA and asymmetry for lesion classification resulted in notable success rates when distinguishing between benign and malignant lesions. In light of these results, skin lesions' shape should be integrated as a fundamental part of future detection techniques in clinical screening.
    Language English
    Publishing date 2022-07-28
    Publishing country Switzerland
    Document type Journal Article
    ZDB-ID 2662592-1
    ISSN 2077-0383
    ISSN 2077-0383
    DOI 10.3390/jcm11154392
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

  8. Article ; Online: Predictive Models for the Characterization of Internal Defects in Additive Materials from Active Thermography Sequences Supported by Machine Learning Methods.

    Rodríguez-Martín, Manuel / Fueyo, José G / Gonzalez-Aguilera, Diego / Madruga, Francisco J / García-Martín, Roberto / Muñóz, Ángel Luis / Pisonero, Javier

    Sensors (Basel, Switzerland)

    2020  Volume 20, Issue 14

    Abstract: The present article addresses a generation of predictive models that assesses the thickness and length of internal defects in additive manufacturing materials. These modes use data from the application of active transient thermography numerical ... ...

    Abstract The present article addresses a generation of predictive models that assesses the thickness and length of internal defects in additive manufacturing materials. These modes use data from the application of active transient thermography numerical simulation. In this manner, the raised procedure is an ad-hoc hybrid method that integrates finite element simulation and machine learning models using different predictive feature sets and characteristics (i.e., regression, Gaussian regression, support vector machines, multilayer perceptron, and random forest). The performance results for each model were statistically analyzed, evaluated, and compared in terms of predictive performance, processing time, and outlier sensibility to facilitate the choice of a predictive method to obtain the thickness and length of an internal defect from thermographic monitoring. The best model to predictdefect thickness with six thermal features was interaction linear regression. To make predictive models for defect length and thickness, the best model was Gaussian process regression. However, models such as support vector machines also had significative advantages in terms of processing time and adequate performance for certain feature sets. In this way, the results showed that the predictive capability of some types of algorithms could allow for the detection and measurement of internal defects in materials produced by additive manufacturing using active thermography as a non-destructive test.
    Language English
    Publishing date 2020-07-17
    Publishing country Switzerland
    Document type Journal Article
    ZDB-ID 2052857-7
    ISSN 1424-8220 ; 1424-8220
    ISSN (online) 1424-8220
    ISSN 1424-8220
    DOI 10.3390/s20143982
    Database MEDical Literature Analysis and Retrieval System OnLINE

    More links

    Kategorien

To top